Skip to content

score-p/scorep_plugin_hdeem

Repository files navigation

Score-P HDEEM Energy Measurement Plugin

Compilation and Installation

Prerequisites

To compile this plugin, you need:

  • A C++ 14 compiler

  • Score-P Version 2+ (SCOREP_METRIC_PLUGIN_VERSION >= 1)

  • The hdeem library and header files by BULL/ATOS

Building and installation

  1. Create a build directory

     mkdir build
     cd build
    
  2. Invoke CMake

     cmake ..
    

    The following settings can be customized:

    • HDEEM_BMC_USER HDEEM_BMC_PASS

      Required for out of band access

    • HDEEM_INCLUDE_DIRS

      Directory where hdeem.h is located

    • HDEEM_LIBRARIES

      The full path of libhdeem.so, including the file name, e.g. /usr/local/hdeem/libhdeem.so.1

    • SCOREP_CONFIG

      Path to the scorep-config tool including the file name

      Note:

      If you have scorep-config in your PATH, it should be found by CMake.

    • CMAKE_INSTALL_PREFIX

      Directory where the resulting plugin will be installed (lib/ suffix will be added)

    • ENABLE_MPI (only applicable to the hdeem_sync_plugin)

      Enables MPI communication for the sync plugin, and allows to run more than one MPI process per node.

  3. Invoke make

     make
    
  4. Install the files (optional)

     make install
    

Note:

Make sure to add the subfolder lib to your LD_LIBRARY_PATH.

Usage

To add a hdeem metric to your trace, you have to add hdeem_plugin to the environment variable SCOREP_METRIC_PLUGINS. This is the preferred version for tracing. It preserves the best possible time resolution of the measurements.

To add the synchronous metric, add hdeem_sync_plugin to the environment variable SCOREP_METRIC_PLUGINS. This can be useful for profiling. Measurements are only taken at events, e.g. enter / leave of regions.

You have to add the list of the metric channel you are interested in to the environment variable SCOREP_METRIC_HDEEM_PLUGIN or SCOREP_METRIC_HDEEM_SYNC_PLUGIN.

Note: Score-P does not support per-host post-mortem plugins with profiling. If you want to use the post-mortem (hdeem_plugin) plugin, you should enable tracing and disable profiling by using:

export SCOREP_ENABLE_PROFILING="false"
export SCOREP_ENABLE_TRACING="true"

The sync plugin (hdeem_sync_plugin) works with profiling and tracing.

Note: The sync plugin is implemented as a strictly synchronous plugin. Therefor, it measures per thread. As hdeem can just be used node-wide, the plugin does some thread and if enabled MPI operations in order to obtain the responsible thread and process. The trace file might hold some traces that are reported as 0. The profile might report wrong profiling statistics. Moreover, the plugin reports mJ and mW as interfer values. This operations are necessary to be compatible with PTF (http://periscope.in.tum.de/)

Environment variables

  • SCOREP_METRIC_HDEEM_PLUGIN (only applicable to the hdeem_plugin)

    Comma-separated list of sensors, can also contain wildcards, e.g. Blade,CPU*

  • SCOREP_METRIC_HDEEM_SYNC_PLUGIN (only applicable to the hdeem_sync_plugin)

    Comma-separated list of sensors, and physical quantity. Can also contain wildcards, e.g. BLADE/P,*/E

  • SCOREP_METRIC_HDEEM_PLUGIN_CONNECTION or SCOREP_METRIC_HDEEM_SYNC_PLUGIN_CONNECTION (default BMC)

    Can be set to either INBAND for inband connection to the BMC via PCIe/GPIO (default) or OOB for out-of-band connection via out-of-band / side-band IPMI.

    It is recommended to use INBAND as it is faster and has better time synchronization.

  • SCOREP_METRIC_HDEEM_PLUGIN_VERBOSE or SCOREP_METRIC_HDEEM_SYNC_PLUGIN_VERBOSE (default WARN)

    Controls the output verbosity of the plugin. Possible values are: FATAL, ERROR, WARN, INFO, DEBUG, TRACE (TRACE currently not used). If set to any other value, DEBUG is used. Case in-sensitive.

  • SCOREP_METRIC_HDEEM_PLUGIN_TIMER (only applicable to the hdeem_plugin, default BMC)

    Can be set to either BMC for using the timestamps from the BMC or NODE to use the timestamps of the node. BMC is usually much better.

  • SCOREP_METRIC_HDEEM_SYNC_PLUGIN_STATS_TIMEOUT_MS (only applicable to the hdeem_sync_plugin, default 10)

    Can be set to any integer variable. Defines the time in milliseconds after a hdeem_get_stats becomes invalid. The measurement of energy or power values might be at any time point since the event to this time.

  • SCOREP_METRIC_HDEEM_SYNC_PLUGIN_GET_NEW_STATS (only applicable to the hdeem_sync_plugin, default 10)

    Can be set to any integer variable. Defines the time in milliseconds after a new measurement is taken. Events that triger the HDEEM plugin in between, will deliver the last value. This is supposed to reduce the measurement overhead of HDEEM (i.e. 5 ms).

If anything fails:

  1. Check whether the plugin library can be loaded from the LD_LIBRARY_PATH.

  2. Check whether your hdeem functionality is working properly by using the hdeem command line tools.

  3. Write a mail to the authors.

Authors

  • Thomas Ilsche (thomas.ilsche at tu-dresden dot de)
  • Mario Bielert (mario.bielert at tu-dresden dot de)
  • Andreas Gocht (andreas.gocht at tu-dresden dot de)

About

No description, website, or topics provided.

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published