Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Activations with large fluence are inaccurate. #94

Open
pkienzle opened this issue Oct 25, 2024 · 1 comment
Open

Activations with large fluence are inaccurate. #94

pkienzle opened this issue Oct 25, 2024 · 1 comment

Comments

@pkienzle
Copy link
Collaborator

Try 1g Al with thermal flux activation 27Al(act)28Al @ 0 hrs

flux activity
1e13 2.4535e6
1e14 2.4535e7
1e15 2.4534e8
1e16 2.4531e9
1e17 2.4499e10
1e18 2.4189e11
1e19 2.1207e12
1e20 5.7135e12
@pkienzle
Copy link
Collaborator Author

pkienzle commented Dec 4, 2024

Added a comment in the docs, but should probably flag inputs with high fluence.