Allow read/write callbacks to respond with modbus exception codes #1

Open
wants to merge 1 commit into
base: master
Choose a base branch
from
Open
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
21 changes: 11 additions & 10 deletions doc/modbus_reply_callback.txt
Original file line number Diff line number Diff line change
Expand Up @@ -24,7 +24,7 @@ typedef struct {
DESCRIPTION
-----------
*modbus_set_reply_callbacks()* has to be used to set the callback-structure into the
libmodbus-context. An optional parameter _user_ctx_ can be suppied which will be passed to the
libmodbus-context. An optional parameter _user_ctx_ can be supplied which will be passed to the
callback function, typically for context purpose.

The *modbus_reply_callback()* function receives the request-byte-buffer and its byte-length as
Expand All @@ -43,16 +43,16 @@ a RTU-slave, the additional *accept_rtu_slave*-callback has to be provided.
At different stages *modbus_reply_callback()* calls these callbacks by passing different arguments and
the user-context-pointer _user_ctx_ as the first one.

The first callback invoked by modbus_reply_callback() is *accept_rtu_slave* if the user implements a
The first callback invoked by modbus_reply_callback() is *accept_rtu_slave* if the user implements an
RTU-slave. In its implementation the user has to check whether the slave-id, _slave_, which was
decoded from the request, should be answered to or not and returning TRUE if so, otherwise FALSE.
Returning FALSE will make *modbus_reply_callback()* exit immedialty and return 0.
Returning FALSE will make *modbus_reply_callback()* exit immediately and return 0.

All callbacks hereafter receive the following arguments:

* _slave_ still indicating the RTU-slave-id if the modbus-instance is in RTU-mode otherwise it has
no meaning.
* _function_ containting the value of the modbus-function decoded from the request.
* _function_ containing the value of the modbus-function decoded from the request.
* _address_, the first register or coil-address.
* _nb_, the number of values to be handled.
* _bytes[]_, the byte-buffer containing the raw-data (write-request) or where the raw-data has to
Expand All @@ -63,7 +63,7 @@ All callbacks hereafter receive the following arguments:
*modbus_reply_callback()* is then doing some basic sanitizing on standard-specific parameters before
calling the second callback *verify*.

This is done to verify whether the access is valid for this instance in regards to the address-range
This is done to verify whether the access is valid for this instance in regard to the address-range
or the modbus-function of the request. The user has to return 0 if the range defined by _address_
and _nb_ is inside the device's range and the modbus-function can be handled.

Expand All @@ -80,11 +80,12 @@ modbus-specification and needs to be encoded, or decoded, properly inside the ca
Coils are encoded as up to 8 coils per byte, registers are 16-bit wide and thus consume 2 bytes of the
buffer per value. See below.

The return value of the read-callback. Negative numbers or zero are interpreted as no response
should be send. To, for example, trigger a timeout on the other side.

The write-callbacks has to return 0 to signal success or a negative number to make the library
not send any response.
The read-callback should return the length (bytes) of data written if successful.
The write-callback should return 0 to signal success.
The read and write callbacks may return a negated error code within the range of modbus protocol
exception error codes (-EMBXILFUN to -EMBXGTAR) to send an exception response. Any other negative
numbers or zero are interpreted as no response should be sent. To, for example, trigger a timeout
on the other side.

The library does not do any differentiation regarding the actual modbus-function and the appropriate
invoked callback. All MODBUS_READ-functions are handled by the read-callback, all
Expand Down
17 changes: 16 additions & 1 deletion src/modbus-reply.c
Original file line number Diff line number Diff line change
Expand Up @@ -306,7 +306,7 @@ int modbus_reply_callback(modbus_t *ctx, const uint8_t *req, int req_length)

/* user verification was successful */

int rc;
int rc = 0;
rsp_length = ctx->backend->build_response_basis(&sft, rsp);

switch (function) {
Expand Down Expand Up @@ -410,6 +410,21 @@ int modbus_reply_callback(modbus_t *ctx, const uint8_t *req, int req_length)
}

send_response:
/* Check if a user read/write callback returned a negated error code within the
* range of modbus protocol exceptions, if so respond with that exception */
Copy link
Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Alternatively could get the user to set errno in the callback, instead of returning the negated error number if you think that's better

if (rc < 0) {
int modbus_errno = -rc;
int protocol_exception = modbus_errno - MODBUS_ENOBASE;
if (protocol_exception > 0 && protocol_exception < MODBUS_EXCEPTION_MAX) {
rsp_length = response_exception(
ctx, &sft,
protocol_exception, rsp, FALSE,
"%s: 0x%0X (%s)\n",
modbus_strerror(modbus_errno),
function, function_name);
}
}

if ((ctx->backend->backend_type == _MODBUS_BACKEND_TYPE_RTU &&
slave == MODBUS_BROADCAST_ADDRESS) ||
rsp_length == 0) /* this indicates that the user does not want us to send response,
Expand Down