forked from tbnobody/OpenDTU
-
-
Notifications
You must be signed in to change notification settings - Fork 67
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
- Loading branch information
Showing
15 changed files
with
222 additions
and
810 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -1,88 +1,3 @@ | ||
# MQTT Topics | ||
|
||
The base topic, as configured in the web GUI is prepended to all follwing topics. | ||
|
||
## General topics | ||
|
||
| Topic | R / W | Description | Value / Unit | | ||
| --------------------------------------- | ----- | ---------------------------------------------------- | -------------------------- | | ||
| dtu/ip | R | IP address of OpenDTU | IP address | | ||
| dtu/hostname | R | Current hostname of the dtu (as set in web GUI) | | | ||
| dtu/rssi | R | WiFi network quality | db value | | ||
| dtu/status | R | Indicates whether OpenDTU network is reachable | online / offline | | ||
| dtu/uptime | R | Time in seconds since startup | seconds | | ||
|
||
## Inverter total topics | ||
|
||
Enabled inverter means, that only inverters with "Poll inverter data" enabled are considered. | ||
|
||
| Topic | R / W | Description | Value / Unit | | ||
| --------------------------------------- | ----- | ---------------------------------------------------- | -------------------------- | | ||
| ac/power | R | Sum of AC active power of all enabled inverters | W | | ||
| ac/yieldtotal | R | Sum of energy converted to AC since reset watt hours of all enabled inverters | Kilo watt hours (kWh) | | ||
| ac/yieldday | R | Sum of energy converted to AC per day in watt hours of all enabled inverters | Watt hours (Wh) | ||
| ac/is_valid | R | Indicator whether all enabled inverters where reachable | 0 or 1 | | ||
| dc/power | R | Sum of DC power of all enabled inverters | Watt (W) | | ||
| dc/irradiation | R | Produced power of all enabled inverter stripes with defined irradiation settings divided by sum of all enabled inverters irradiation | % | | ||
| dc/is_valid | R | Indicator whether all enabled inverters where reachable | 0 or 1 | | ||
|
||
## Inverter specific topics | ||
|
||
serial will be replaced with the serial number of the inverter. | ||
|
||
| Topic | R / W | Description | Value / Unit | | ||
| --------------------------------------- | ----- | ---------------------------------------------------- | -------------------------- | | ||
| [serial]/name | R | Name of the inverter as configured in web GUI | | | ||
| [serial]/device/bootloaderversion | R | Bootloader version of the inverter | | | ||
| [serial]/device/fwbuildversion | R | Firmware version of the inverter | | | ||
| [serial]/device/fwbuilddatetime | R | Build date / time of inverter firmware | | | ||
| [serial]/device/hwpartnumber | R | Hardware part number of the inverter | | | ||
| [serial]/device/hwversion | R | Hardware version of the inverter | | | ||
| [serial]/status/reachable | R | Indicates whether the inverter is reachable | 0 or 1 | | ||
| [serial]/status/producing | R | Indicates whether the inverter is producing AC power | 0 or 1 | | ||
| [serial]/status/last_update | R | Unix timestamp of last inverter statistics udpate | seconds since JAN 01 1970 (UTC) | | ||
|
||
### AC channel / global specific topics | ||
|
||
| Topic | R / W | Description | Value / Unit | | ||
| --------------------------------------- | ----- | ---------------------------------------------------- | -------------------------- | | ||
| [serial]/0/current | R | AC current in ampere | Ampere (A) | | ||
| [serial]/0/efficiency | R | Ratio AC Power over DC Power in percent | % | | ||
| [serial]/0/frequency | R | AC frequency in hertz | Hertz (Hz) | | ||
| [serial]/0/power | R | AC active power in watts | Watt (W) | | ||
| [serial]/0/powerdc | R | DC power in watts | Watt (W) | | ||
| [serial]/0/powerfactor | R | Power factor in percent | % | | ||
| [serial]/0/reactivepower | R | AC reactive power in VAr | VAr | | ||
| [serial]/0/temperature | R | Temperature of inverter in degree celsius | Degree Celsius (°C) | | ||
| [serial]/0/voltage | R | AC voltage in volt | Volt (V) | | ||
| [serial]/0/yieldday | R | Energy converted to AC per day in watt hours | Watt hours (Wh) | | ||
| [serial]/0/yieldtotal | R | Energy converted to AC since reset watt hours | Kilo watt hours (kWh) | | ||
|
||
### DC input channel topics | ||
|
||
[1-4] represents the different inputs. The amount depends on the inverter model. | ||
|
||
| Topic | R / W | Description | Value / Unit | | ||
| --------------------------------------- | ----- | ---------------------------------------------------- | -------------------------- | | ||
| [serial]/[1-4]/current | R | DC current of specific input in ampere | Ampere (A) | | ||
| [serial]/[1-4]/name | R | Name of the DC input channel as configured in web GUI| | | ||
| [serial]/[1-4]/irradiation | R | Ratio DC Power over set maximum power (in web GUI) | % | | ||
| [serial]/[1-4]/power | R | DC power of specific input in watt | Watt (W) | | ||
| [serial]/[1-4]/voltage | R | DC voltage of specific input in volt | Volt (V) | | ||
| [serial]/[1-4]/yieldday | R | Energy converted to AC per day on specific input | Watt hours (Wh) | | ||
| [serial]/[1-4]/yieldtotal | R | Energy converted to AC since reset on specific input | Kilo watt hours (kWh) | | ||
|
||
### Inverter limit specific topics | ||
|
||
cmd topics are used to set values. Status topics are updated from values set in the inverter. | ||
|
||
| Topic | R / W | Description | Value / Unit | | ||
| ----------------------------------------- | ----- | ---------------------------------------------------- | -------------------------- | | ||
| [serial]/status/limit_relative | R | Current applied production limit of the inverter | % of total possible output | | ||
| [serial]/status/limit_absolute | R | Current applied production limit of the inverter | Watt (W) | | ||
| [serial]/cmd/limit_persistent_relative | W | Set the inverter limit as a percentage of total production capability. The value will survive the night without power. The updated value will show up in the web GUI and limit_relative topic immediatly. | % | | ||
| [serial]/cmd/limit_persistent_absolute | W | Set the inverter limit as a absolute value. The value will survive the night without power. The updated value will set immediatly within the inverter but show up in the web GUI and limit_relative topic after around 4 minutes. If you are using a already known inverter (known Hardware ID), the updated value will show up within a few seconds. | Watt (W) | | ||
| [serial]/cmd/limit_nonpersistent_relative | W | Set the inverter limit as a percentage of total production capability. The value will reset to the last persistent value at night without power. The updated value will show up in the web GUI and limit_relative topic immediatly. The value must be published non-retained, otherwise it will be ignored! | % | | ||
| [serial]/cmd/limit_nonpersistent_absolute | W | Set the inverter limit as a absolute value. The value will reset to the last persistent value at night without power. The updated value will set immediatly within the inverter but show up in the web GUI and limit_relative topic after around 4 minutes. If you are using a already known inverter (known Hardware ID), the updated value will show up within a few seconds. The value must be published non-retained, otherwise it will be ignored! | Watt (W) | | ||
| [serial]/cmd/power | W | Turn the inverter on (1) or off (0) | 0 or 1 | | ||
| [serial]/cmd/restart | W | Restarts the inverters (also resets YieldDay) | 1 | | ||