Docs: added more comments for Validation and Base Load.
Browse files Browse the repository at this point in the history
  • Loading branch information
equinor-schen committed Mar 22, 2024
1 parent 472e592 commit ac9cd7c
Showing 1 changed file with 3 additions and 3 deletions.
6 changes: 3 additions & 3 deletions docs/docs/about/modelling/workflow/generic_workflow.md
Original file line number Diff line number Diff line change
Expand Up @@ -76,11 +76,11 @@ The [workflow](#workflow) below will outline what is necessary to obtain for eac
ide4_A -. yes .-> ide4_A_1{"`Invalid Compressors?`"};
ide4_A_1 -. yes .-> ide4_A_1_1(["`Either head or rate is too high`"]);
ide4_A_1_1 --> ide4_A_1_2(["`Plot operational points and adjust charts to fit historical data`"]);
ide4_A_1_1 --> ide4_A_1_2(["`Based on the qaulity and uncertianty of data, user can either adjust history operational points or charts to fit history data`"]);
ide4_A -. yes .-> ide4_A_3{"`Invalid Pumps?`"};
ide4_A_3 -. yes .-> ide4_A_3_1(["`Either head or rate is too high`"]);
ide4_A_3_1 --> ide4_A_3_2(["`Plot operational points and adjust charts to fit historical data`"]);
ide4_A_3_1 --> ide4_A_3_2(["`Based on the qaulity and uncertianty of data, user can either adjust history operational points or charts to fit hisotry data`"]);
ide4_A -. yes .-> ide4_A_4{"`Invalid Generator Set?`"};
ide4_A_4 -. yes .-> ide4_A_4_1(["`Check maximum and minimum facility power consumption values are within the range of the specified generator set`"]);
Expand Down Expand Up @@ -120,7 +120,7 @@ All subsurface profiles must be in calendar day rate Sm<sup>3</sup>/day and with
To simplify certain models, there could be some common assumptions made. Here are some examples:

- **Base Load**: As eCalc™ is not simulating the whole facility there are often energy consumers that are not modelled.
Typically these energy consumers, related to things such as the energy consumption of living quarters and direct energy consumers dependent on there being production/injection, are often constant loads.
Typically these energy consumers, related to things such as the energy consumption of living quarters and direct energy consumers, which are not varying with the amount of their production/injection, are often constant loads.
These smaller constant loads are then grouped into a larger term, called the "baseload". This is assumed to be constant and independent of the production rate of the facility.
- **Recompressor**: The main function of a recompressor is to compressor gas from separator pressures back up to the inlet separator pressure.
If this compressor is small and has little fluctuation in its load, or its processed gas rate and composition are unknown,
Expand Down