Skip to content

Commit

Permalink
[PC-1640] Launch Opta Analog Expansion (#2085)
Browse files Browse the repository at this point in the history
* valve-connection.png image updated

* datasheet started

* A little table update

* A little table update

* RTD section covered

* Images pending

* Pending I/O channels description

* waiting images

* structure almost ready

* Minor updates

* product.md updated

* Minor Update

* tech-specs updated

* Features ready

* step file added

* tutoriales folder added

* typo fixed

* Features updated

* Features updated 2

* icon update

* SVG updated

* rtd image added

* datasheet update

* illustration update

* Analog Expansion Seccion

* digital section covered

* section titles added

* Analog Voltage input section

* Current input section

* image update

* current sensor 2.0

* current sensor 2.0

* RTD section started

* typo

* typo

* typo

* code update

* RTD section started

* RTD section ready

* outputs section started

* voltage output started

* analog voltage out added

* LED and final section started

* LED section added

* My final review

* datasheet update

* images added

* typo

* typo

* Update content/hardware/07.opta/opta-family/opta-analog-exp/features.md

Co-authored-by: Fr4ng <[email protected]>

* Update content/hardware/07.opta/opta-family/opta-analog-exp/features.md

Co-authored-by: Fr4ng <[email protected]>

* Update content/hardware/07.opta/opta-family/opta-analog-exp/features.md

Co-authored-by: Fr4ng <[email protected]>

* minor patch review

* certifications updated

* Opta Expansions sections rearrange

* Tables format update

* headings fix

* not used image deleted

* paragraph edited

* General Library note updated

* General Library note updated

* General Library note updated

* PT100 fixed

* PT100 fixed

* PT100 updated

* Input/output timing added

* Francesca review addresed

* Power more clear

* Small format fixes, Revission row updated to launch date

* store links

* final rephrase

* Julian final review fixes

* Julian final review fixes

* typo

* Fix

* Symbolic links fixed, seconday button revamped

* Small icon fix

* Store link updated

---------

Co-authored-by: Christopher Mendez <[email protected]>
Co-authored-by: Christopher Méndez <[email protected]>
Co-authored-by: Fr4ng <[email protected]>
Co-authored-by: jcarolinares <[email protected]>
  • Loading branch information
5 people authored Jul 25, 2024
1 parent 71239bc commit 6fffe5c
Show file tree
Hide file tree
Showing 31 changed files with 2,892 additions and 302 deletions.
Original file line number Diff line number Diff line change
@@ -0,0 +1,5 @@
software:
- arduino-ide
- arduino-cli
- iot-cloud
- plc-ide
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.

Large diffs are not rendered by default.

Binary file not shown.
47 changes: 47 additions & 0 deletions content/hardware/07.opta/opta-family/opta-analog-exp/features.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,47 @@
<FeatureDescription>

**Arduino Opta® Analog Expansions** are designed to multiply your Opta® micro PLC capabilities with the addition of eight programmable analog inputs for connecting your digital or analog sensors, allowing you to interface with voltage, current or resistive sensors, eight analog outputs for voltage or current and four PWM outputs.

Opta Analog Expansion allows professionals to scale up industrial and building automation projects while taking advantage of the Arduino ecosystem.

</FeatureDescription>

<FeatureList>

<Feature title="Configurability" image="configurability">

All the eight available channels can be configured by software as analog input or analog output. Two of those channels can get 3 wires RTD readings and the expansions have four additional PWM outputs, with a user-defined output voltage configurable from 8 to 40 VDC using the V<sub>PWM</sub> terminal.

</Feature>

<Feature title="Expandability" image="communication">

Up to five snap-on modules managed to multiply and mix your set of I/Os with seamless detection.

</Feature>

<Feature title="Industrial Temperature Range" image="temperature-sensor">

Arduino Opta® Analog Expansion has a highly reliable design operating at industrial temperature ranges (-20 °C to +50 °C).

</Feature>

<Feature title="Programming Languages Supported" image="file-icon">

* Arduino sketch
* IEC-61131-3:
* Ladder (LD)
* Sequential Function Chart (SFC)
* Function Block Diagram (FBD)
* Structured Text (ST)
* Instruction List (IL)

</Feature>

<Feature title="Suitable to DIN Rail" image="configurability">

Thanks to its form factor, it can be attached to a Din Rail mount system, providing quick access to all the I/O's.

</Feature>

</FeatureList>
564 changes: 564 additions & 0 deletions content/hardware/07.opta/opta-family/opta-analog-exp/image.svg
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
13 changes: 13 additions & 0 deletions content/hardware/07.opta/opta-family/opta-analog-exp/product.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,13 @@
---
title: Opta Analog Expansion
url_shop: https://store.arduino.cc/products/opta-ext-a0602
url_guide: /tutorials/opta-analog-exp/user-manual
primary_button_url: /tutorials/opta/user-manual#opta-analog-expansion
primary_button_title: User Manual
secondary_button_url: /software/plc-ide/
secondary_button_title: PLC IDE Guide
core: arduino:mbed_opta
certifications: [FCC, CE, UKCA, cULus, ENEC]
---

The **Arduino Opta® Analog Expansion** is a plug-and-play extension to the **Opta® PLC Controller** that expands its capabilities with more **inputs** with multiple functions such as digital, analog voltage, analog current or temperature and more **outputs** with analog voltage, analog current and PWM functionalities. Fully compatible with the Arduino Ecosystem.
Original file line number Diff line number Diff line change
@@ -0,0 +1 @@
These are the technical specifications for Arduino Opta® Analog Expansion.
Original file line number Diff line number Diff line change
@@ -0,0 +1,32 @@
Board:
SKUs:
Arduino Opta® Ext A0602: AFX00007
Microcontroller:
ID: Renesas R7FA4M1AB3CFM ARM® Cortex®-M4
Cortex-M4 core: Up to 48 MHz
Input:
Configurable digital / analog inputs: 8x
Digital operational range: 0-24 V
Digital configurable threshold: Yes (supports 0-10 V logic)
Analog resolution: 16 bit
Analog input voltage range: 0-10 V
Analog input current range: 0-25 mA
Analog input resistance range: 0-1 MΩ
Output:
Configurable analog outputs: 8x, (2x used simultaneously max recommended)
DAC resolution: 13 bit
Analog output voltage range: 0-11 V
Analog output current range: 0-25 mA
PWM outputs: 4x
PWM voltage output: 8-40 V
Power:
Input voltage: 12-24 VDC
Dimensions:
Weight: 130 g
Width: 70 mm
Length: 89 mm
Height: 62 mm
IP Protection: IP20
Programming:
Arduino programming language: Via Arduino IDE, Arduino CLI, Arduino Cloud
IEC-61131-3: Ladder Diagram (LD), Function Block Diagram (FBD), Sequential Function Chart (SFC), Structured Text (ST), Instruction List (IL)
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
2,109 changes: 1,807 additions & 302 deletions content/hardware/07.opta/opta-family/opta/tutorials/01.user-manual/content.md

Large diffs are not rendered by default.

0 comments on commit 6fffe5c

Please sign in to comment.