&specification | ||
BuildingType='LDN_TE_pre1900' | ||
BuildingName='LDN_TE_pre1900' | ||
Height=9.3 | ||
FootprintArea=65.6 | ||
WallExternalArea=147.1 | ||
WWR=0.2 | ||
RatioInternalVolume=0.1 | ||
WallThickness=0.168 | ||
WallEffectiveConductivity=0.596 | ||
WallDensity=1626.237 | ||
WallCp=822.626 | ||
Wallx1=0.291 | ||
FloorThickness=0.235 | ||
GroundFloorEffectiveConductivity=0.752 | ||
GroundFloorDensity=1540.426 | ||
GroundFloorCp=1001.657 | ||
GroundDepth=2.0 | ||
ExternalGroundConductivity=0.0001 | ||
WindowThickness=0.004 | ||
WindowEffectiveConductivity=1.050 | ||
WindowDensity=2500.000 | ||
WindowCp=840.000 | ||
InternalMassDensity=1056.612 | ||
InternalMassCp=1286.081 | ||
IndoorAirDensity=1.2754 | ||
IndoorAirCp=1005 | ||
WallInternalConvectionCoefficient=1.27 | ||
InternalMassConvectionCoefficient=8.29 | ||
FloorInternalConvectionCoefficient=0.96 | ||
WindowInternalConvectionCoefficient=2.34 | ||
WallExternalConvectionCoefficient=8.51 | ||
WindowExternalConvectionCoefficient=5.29 | ||
WallExternalEmissivity=0.900 | ||
WallInternalEmissivity=0.910 | ||
InternalMassEmissivity=0.910 | ||
WindowExternalEmissivity=0.880 | ||
WindowInternalEmissivity=0.880 | ||
WindowTransmissivity=0.800 | ||
WindowAbsorbtivity=0.150 | ||
WindowReflectivity=0.050 | ||
WallTransmissivity=0.000 | ||
WallAbsorbtivity=0.625 | ||
WallReflectivity=0.375 | ||
WallBuildingViewFactor=0.354 | ||
WallGroundViewFactor=0 ! ASHRAE 140 - Case 600 | ||
WallSkyViewFactor=0.646 ! assumed isolated building wall(0.5) and roof (1.0) | ||
Occupants=0 | ||
MetabolicRate=0 | ||
LatentSensibleRatio=0 | ||
ApplianceRating=0 | ||
TotalNumberofAppliances=1 | ||
ApplianceUsageFactor=1 | ||
MaxHeatingPower=1000000.0 ! ASHRAE 140 - Case 600 | ||
HeatingSystemEfficiency=0.9 ! Assumed | ||
MaxCoolingPower=1000000.0 ! ASHRAE 140 - Case 600 | ||
CoolingSystemCOP=3.4 ! Assumed | ||
VentilationRate=0.6 ! ASHRAE 140 - Case 600 (ach) | ||
IndoorAirStartTemperature=20 | ||
IndoorMassStartTemperature=20 | ||
WallIndoorSurfaceTemperature=18 | ||
WallOutdoorSurfaceTemperature=5 | ||
WindowIndoorSurfaceTemperature=18 | ||
WindowOutdoorSurfaceTemperature=5 | ||
GroundFloorIndoorSurfaceTemperature=18 | ||
GroundFloorOutdoorSurfaceTemperature=10.0 | ||
HeatingSetpointTemperature=18 ! ASHRAE 140 - Case 600 | ||
CoolingSetpointTemperature=26 ! ASHRAE 140 - Case 600 | ||
WaterTankTemperature=18 ! Minimised in Volume as not considered in BESTEST - Case 600 | ||
InternalWallWaterTankTemperature=18 ! ASHRAE 140 - Case 600 - influence minimised by volume | ||
ExternalWallWaterTankTemperature=18 ! ASHRAE 140 - Case 600 - influence minimised by volume | ||
WaterTankWallThickness=0.055 ! ASHRAE 140 - Case 600 - influence minimised by volume | ||
MainsWaterTemperature=11 ! ASHRAE 140 - Case 600 - influence minimised by volume | ||
WaterTankWaterVolume=0.0046 ! ASHRAE 140 - Case 600 - influence minimised by volume | ||
WaterTankSurfaceArea=1 ! ASHRAE 140 - Case 600 - influence minimised by volume | ||
HotWaterHeatingSetpointTemperature=10 ! ASHRAE 140 - Case 600 - influence minimised by volume | ||
HotWaterTankWallEmissivity=0.9 ! ASHRAE 140 - Case 600 - influence minimised by volume | ||
DomesticHotWaterTemperatureInUseInBuilding=15 ! ASHRAE 140 - Case 600 - influence minimised by volume | ||
InternalWallDHWVesselTemperature=20 ! ASHRAE 140 - Case 600 - influence minimised by volume | ||
ExternalWallDHWVesselTemperature=20 ! ASHRAE 140 - Case 600 - influence minimised by volume | ||
DHWVesselWallThickness=0.47 ! ASHRAE 140 - Case 600 - influence minimised by volume | ||
DHWWaterVolume=0.0001 ! Minimised for ASHRAE BESTEST | ||
DHWSurfaceArea=0.00001 ! Minimised for ASHRAE BESTEST | ||
DHWVesselEmissivity=0.9 ! Based on Internal ASHARE 140 | ||
HotWaterFlowRate=0.0 ! Minimised for ASHRAE BESTEST | ||
DHWDrainFlowRate=0.0 ! Minimised for ASHRAE BESTEST | ||
DHWSpecificHeatCapacity=4180.1 ! of water | ||
HotWaterTankSpecificHeatCapacity=29.1830 ! ASHRAE 140 - Case 600 - influence minimised by volume | ||
DHWVesselSpecificHeatCapacity=29.1830 ! ASHRAE 140 - Case 600 - influence minimised by volume | ||
DHWDensity=1000 ! of water | ||
HotWaterTankWallDensity=15.8075 ! ASHRAE 140 - Case 600 - influence minimised by volume | ||
DHWVesselDensity=15.8075 ! ASHRAE 140 - Case 600 - influence minimised by volume | ||
HotWaterTankBuildingWallViewFactor=0.2 | ||
HotWaterTankInternalMassViewFactor=0.8 | ||
HotWaterTankWallConductivity=0.00001 ! ASHRAE 140 - Case 600 - set to minimise influence | ||
HotWaterTankInternalWallConvectionCoefficient=0.01 ! ASHRAE 140 - Case 600 - set to minimise influence | ||
HotWaterTankExternalWallConvectionCoefficient=0.01 ! ASHRAE 140 - Case 600 - set to minimise influence | ||
DHWVesselWallConductivity=0.00001 ! ASHRAE 140 - Case 600 - set to minimise influence | ||
DHWVesselInternalWallConvectionCoefficient=0.01 ! ASHRAE 140 - Case 600 - set to minimise influence | ||
DHWVesselExternalWallConvectionCoefficient=0.01 ! ASHRAE 140 - Case 600 - set to minimise influence | ||
DHWVesselWallEmissivity=0.9 ! Based on Internal ASHARE 140 | ||
MaximumHotWaterHeatingPower=10 ! Minimised for ASHRAE BESTEST | ||
HotWaterHeatingEfficiency=0.95 | ||
MinimumVolumeOfDHWinUse=2.0 ! altered to 20% of Vwt upon initiation | ||
|
||
/ |
bf3281d
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Hello @MatthewPaskin - this file should be merged into
sample_data
and loaded usingsupy_init
, rather than appearing at the root. We may address this later, but I wanted to bring it to your attention.bf3281d
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
@MatthewPaskin - data should not being committed at all here, i.e. model inputs etc - at the end an example file - but your model setup should be separate
bf3281d
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Hi @sunt05 yes of course, that is the plan but for testing purposes it was quicker for me to leave it in root. Happy to deal with this later.
@suegrimmond This was not intended to be pushed but done yesterday such that Ting could test the code. I have not spent any time to develop a sample version.