Notifications
You must be signed in to change notification settings - Fork 104
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Merge pull request #357 from SlcRobinME/main
Added Raritan Xerus Platform connector help
- Loading branch information
Showing
3 changed files
with
118 additions
and
0 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,113 @@ | ||
--- | ||
uid: Connector_help_Raritan_Xerus_Platform | ||
--- | ||
|
||
# Raritan Xerus Platform | ||
|
||
The Raritan Xerus Platform connector facilitates the monitoring and control of the following Raritan device types: | ||
|
||
- SRC | ||
- PX3 | ||
- PX2 | ||
- PXC | ||
- PX0 | ||
- BCM2 | ||
- PX3TS | ||
- SmartLock | ||
- DX2 SmartSensors | ||
- AMS2 | ||
|
||
> [!NOTE] | ||
> The Xerus MIB implements all Raritan product types. This connector is therefore a generic connector that supports all these devices. Depending on the type of device you connect to, some tables may be empty. | ||
## About | ||
|
||
This connector uses **SNMP** to extract all relevant information concerning the configuration and operating configuration of Raritan's PDU. | ||
|
||
### Version Info | ||
|
||
| Range | Key Features | Based on | System Impact | | ||
|----------------------|------------------|--------------|-------------------| | ||
| 1.0.0.x [SLC Main] | Initial version | - | - | | ||
|
||
### Product Info | ||
|
||
| Range | Supported Firmware | | ||
|-----------|------------------------| | ||
| 1.0.0.x | 4.1.1.5-49961 | | ||
|
||
### System Info | ||
|
||
| Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components | | ||
|-----------|---------------------|-------------------------|-----------------------|-------------------------| | ||
| 1.0.0.x | No | Yes | - | - | | ||
|
||
## Installation and configuration | ||
|
||
### Creation | ||
|
||
#### SNMP Main Connection | ||
|
||
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation: | ||
|
||
SNMP CONNECTION: | ||
|
||
- **IP address/host**: The polling IP or URL of the destination. | ||
- **IP port**: The IP port of the destination. | ||
|
||
SNMP Settings: | ||
|
||
- **Get community string**: The community string used when reading values from the device (default: *public*). | ||
- **Set community string**: The community string used when setting values on the device (default: *private*). | ||
|
||
## Usage | ||
|
||
### Unit | ||
|
||
This page displays information regarding the hardware configuration and the operating state of the sensors of the connected PDU units. | ||
|
||
### Inlets | ||
|
||
This page displays the specifications of each inlet. It also shows the current operating configuration, and it allows you to change the configuration of each inlet sensor. | ||
|
||
### Over Current Protector | ||
|
||
This page displays the specifications of each overcurrent protector. It also shows the current operating configuration, and it allows you to change the configuration of each sensor. | ||
|
||
### Outlets | ||
|
||
This page displays the specifications of all the outlets of the device. It also shows the current operating configuration, and it allows you to change the configuration. | ||
|
||
### External Sensors | ||
|
||
This page displays the specifications of the external sensors. It also shows the current operating configuration, and it allows you to change the configuration of each sensor. | ||
|
||
### Server Reachability | ||
|
||
This page lists the servers connected to the device, their respective IPs, and whether or not they can be reached. | ||
|
||
### Transfer Switch | ||
|
||
This page displays the transfers switches of the device. It also shows the current operating configuration, and it allows you to change the configuration. | ||
|
||
### Control | ||
|
||
On this page, you can control the operation of the connected elements of this device. | ||
|
||
### Measurements Unit/Inlet/Over Current Protector/Outlet/External Sensor/Transfer Switch | ||
|
||
These pages show the availability and values for each unit sensor, inlet, overcurrent protector, etc. | ||
|
||
### Log Unit/Inlet/Over Current Protector/Outlet/External Sensor/Transfer Switch | ||
|
||
These pages log the information for the relevant sensor in a span of two hours. One entity is added to the table corresponding to each minute, so there will be 120 entries per sensor. | ||
|
||
For each sensor, the state, maximum, minimum and average value are logged. There is also an indication of whether the logged information is available. | ||
|
||
### Reliability Data | ||
|
||
This page contains a list of PDU reliability data entries. | ||
|
||
### Reliability Error Log | ||
|
||
This page contains a list of PDU reliability error log entries. |