Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

[EFR32] Updated bootloader binaries for brd4186c and brd4187c #225

Conversation

bhmanda-silabs
Copy link
Collaborator

@bhmanda-silabs bhmanda-silabs commented Aug 28, 2024

Problem / Feature

Due to conflict from DMA channels which are used by SPI communication to the 917 NCP board and the boot loader DMA channel to write onto flash and identified first 60 bytes are not similar to the OTA .gbl content, because of that CRC is failing and failing at verification image.

Fix

OTA functionality with mg24 (BRD4187c) and 917 NCP board,rs9116 and thread apps.

Change overview

Configured slot start address 135184384 and slot size - 54886 and generated boot loader binaries with the updated DMA channel from silabs_slc_1.3.

Testing

Tested OTA functionality with mg24 (BRD4187c) and 917 NCP board,rs9116 , thread and it is working fine. DUT is upgrading with new image.

@bhmanda-silabs bhmanda-silabs merged commit c3e993c into SiliconLabs:main Aug 30, 2024
2 checks passed
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment