Mosquitto 2.x incompatible with default IOTstack config file #266
+7
−2
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
References:
Mosquitto 2.x has introduced a requirement for a
listener
in theconfig file. If this is absent, Mosquitto will bind to the loopback
interface. When Mosquitto is running in a container, this implies no
connectivity.
Mosquitto 2.x has also changed the security defaults. Earlier versions
permitted passwordless access out-of-the box. The new version assumes
a password scheme will be implemented and requires passwordless
access to be an explicit configuration choice.
This PR maintains the IOTstack status quo by:
listener 1883
; andallow_anonymous
with the valuetrue
.Anyone who has already set up a password scheme will need to import
the
listener
line but, presumably, theirallow_anonymous
willalready be active and set to
false