Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,158 @@ | ||
******************************* | ||
** BEGIN Type5b.ddck | ||
******************************* | ||
|
||
************************************************************************************************************************ | ||
** Description: | ||
** Heat Exchanger: Counter Flow | ||
************************************************************************************************************************ | ||
|
||
************************************************************************************************************************ | ||
** Details: | ||
** A zero capacitance sensible heat exchanger is modeled in various configurations. In this instance, a counter flow | ||
** heat exchanger is modeled. Given the hot and cold side inlet temperatures and flow rates, the effectiveness is | ||
** calculated for a given fixed value of the overall heat transfer coefficient. | ||
************************************************************************************************************************ | ||
|
||
*********************************** | ||
** inputs from hydraulic solver | ||
*********************************** | ||
EQUATIONS 6 | ||
CpHot = @cp(HotIn) | ||
CpCold = @cp(ColdIn) | ||
THotIn = @temp(HotIn) | ||
MHot = @mfr(HotIn) | ||
TColdIn = @temp(ColdIn) | ||
MCold = @mfr(ColdIn) | ||
|
||
*********************************** | ||
** outputs to hydraulic solver | ||
*********************************** | ||
EQUATIONS 2 | ||
@temp(HotOut) = THotOut | ||
@temp(ColdOut) = TColdOut | ||
|
||
*********************************** | ||
** outputs to other ddck | ||
*********************************** | ||
|
||
|
||
****************************************************************************************** | ||
** outputs to energy balance in kWh and ABSOLUTE value | ||
****************************************************************************************** | ||
|
||
|
||
*********************************** | ||
** Dependencies with other ddck | ||
*********************************** | ||
|
||
|
||
*********************************** | ||
** Begin CONSTANTS | ||
*********************************** | ||
|
||
|
||
*********************************** | ||
** Begin TYPE | ||
*********************************** | ||
UNIT 1 TYPE 5 | ||
PARAMETERS 4 | ||
** The general heat exchanger model may operate in various configuration modes. Setting this parameter to 2 indicates a | ||
** counter flow arrangement. Do not change this parameter. | ||
2.0 ! 1: Counter flow mode [-] ([2,2]) | ||
|
||
** The specific heat of the fluid flowing through the source side of the counter flow heat exchanger. NOTE: "source" and | ||
** "load" are merely convenient designations; energy will be transfered from the source side to the load side if the | ||
** source side is hotter than the load side. It will be transfered from the load side to the source side if the load | ||
** side is hotter than the source side. | ||
CpHot ! 2: Specific heat of source side fluid [kJ/kg.K] ([0,+Inf]) | ||
|
||
** The specific heat of the fluid flowing through the load side of the counter flow heat exchanger. NOTE: "source" and | ||
** "load" are merely convenient designations; energy will be transfered from the source side to the load side if the | ||
** source side is hotter than the load side. It will be transfered from the load side to the source side if the load | ||
** side is hotter than the source side. | ||
CpCold ! 3: Specific heat of load side fluid [kJ/kg.K] ([0,+Inf]) | ||
|
||
0.0 ! 4: Not used [-] ([0,+Inf]) | ||
|
||
INPUTS 5 | ||
** The temperature of the fluid flowing into the source side of the counter flow heat exchanger. NOTE: "source" and | ||
** "load" are merely convenient designations; energy will be transfered from the source side to the load side if the | ||
** source side is hotter than the load side. It will be transfered from the load side to the source side if the load | ||
** side is hotter than the source side. | ||
THotIn ! 1: Source side inlet temperature [C] ([-Inf,+Inf]) | ||
|
||
** The flow rate of the fluid flowing through the source side of the counter flow heat exchanger. NOTE: "source" and | ||
** "load" are merely convenient designations; energy will be transfered from the source side to the load side if the | ||
** source side is hotter than the load side. It will be transfered from the load side to the source side if the load | ||
** side is hotter than the source side. | ||
MHot ! 2: Source side flow rate [kg/hr] ([0,+Inf]) | ||
|
||
** The temperature of the fluid flowing into the load side of the counter flow heat exchanger. NOTE: "source" and "load" | ||
** are merely convenient designations; energy will be transfered from the source side to the load side if the source | ||
** side is hotter than the load side. It will be transfered from the load side to the source side if the load side is | ||
** hotter than the source side. | ||
TColdIn ! 3: Load side inlet temperature [C] ([-Inf,+Inf]) | ||
|
||
** The flow rate of the fluid flowing through the load side of the counter flow heat exchanger. NOTE: "source" and | ||
** "load" are merely convenient designations; energy will be transfered from the source side to the load side if the | ||
** source side is hotter than the load side. It will be transfered from the load side to the source side if the load | ||
** side is hotter than the source side. | ||
MCold ! 4: Load side flow rate [kg/hr] ([0,+Inf]) | ||
|
||
** Overall heat transfer coefficient of the counter flow heat exchanger. | ||
0,0 ! 5: Overall heat transfer coefficient of exchanger [kJ/hr.K] ([0,+Inf]) | ||
|
||
** initial values | ||
20.0 ! 1: Source side inlet temperature initial value | ||
100.0 ! 2: Source side flow rate initial value | ||
20.0 ! 3: Load side inlet temperature initial value | ||
100.0 ! 4: Load side flow rate initial value | ||
10.0 ! 5: Overall heat transfer coefficient of exchanger initial value | ||
|
||
EQUATIONS 2 ! 6 | ||
** The temperature of the fluid leaving the source side of the counter flow heat exchanger. NOTE: "source" and "load" | ||
** are merely convenient designations; energy will be transfered from the source side to the load side if the source | ||
** side is hotter than the load side. It will be transfered from the load side to the source side if the load side is | ||
** hotter than the source side. | ||
THotOut = [1, 1] ! Source side outlet temperature [C] ([-Inf,+Inf]) | ||
|
||
** The flow rate of fluid exiting the source side of the counter flow heat exchanger. NOTE: "source" and "load" are | ||
** merely convenient designations; energy will be transfered from the source side to the load side if the source side is | ||
** hotter than the load side. It will be transfered from the load side to the source side if the load side is hotter | ||
** than the source side. | ||
! XXX = [1, 2] ! Source side flow rate [kg/hr] ([-Inf,+Inf]) | ||
|
||
** The temperature of the fluid leaving the load side of the counter flow heat exchanger. NOTE: "source" and "load" are | ||
** merely convenient designations; energy will be transfered from the source side to the load side if the source side is | ||
** hotter than the load side. It will be transfered from the load side to the source side if the load side is hotter | ||
** than the source side. | ||
TColdOut = [1, 3] ! Load side outlet temperature [C] ([-Inf,+Inf]) | ||
|
||
** The flow rate of fluid exiting the load side of the counter flow heat exchanger. NOTE: "source" and "load" are merely | ||
** convenient designations; energy will be transfered from the source side to the load side if the source side is hotter | ||
** than the load side. It will be transfered from the load side to the source side if the load side is hotter than the | ||
** source side. | ||
! XXX = [1, 4] ! Load side flow rate [kg/hr] ([-Inf,+Inf]) | ||
|
||
** The total heat transfer rate between the fluids in the counter flow heat exchanger. | ||
! XXX = [1, 5] ! Heat transfer rate [kJ/hr] ([-Inf,+Inf]) | ||
|
||
** The effectiveness of the counter flow heat exchanger. | ||
! XXX = [1, 6] ! Effectiveness [-] ([-Inf,+Inf]) | ||
|
||
|
||
*********************************** | ||
** Monthly printer | ||
*********************************** | ||
|
||
|
||
*********************************** | ||
** Hourly printer | ||
*********************************** | ||
|
||
|
||
*********************************** | ||
** Online Plotter | ||
*********************************** | ||
|