Skip to content

Commit

Permalink
Merge pull request #4 from Frankkkkk/moar
Browse files Browse the repository at this point in the history
Add moar things
  • Loading branch information
Frankkkkk committed Oct 20, 2023
2 parents 0d992b5 + 32e9c4c commit 22c1691
Show file tree
Hide file tree
Showing 8 changed files with 419 additions and 77 deletions.
21 changes: 21 additions & 0 deletions .github/workflows/nose2.yaml
Original file line number Diff line number Diff line change
@@ -0,0 +1,21 @@
name: Python unit tests

on:
pull_request:

jobs:
unittests:
runs-on: ubuntu-latest

steps:
- uses: actions/checkout@v2
- uses: actions/setup-python@v2
with:
python-version: "3.10"

- name: Install dependencies
run: >-
python -m pip install --user --upgrade nose2 websocket-client dpath
- name: Unit test
run: >-
nose2
1 change: 1 addition & 0 deletions Pipfile
Original file line number Diff line number Diff line change
Expand Up @@ -9,6 +9,7 @@ websocket-client = "*"

[dev-packages]
flake8 = "*"
nose2 = "*"

[requires]
python_version = "3.10"
57 changes: 31 additions & 26 deletions Pipfile.lock

Some generated files are not rendered by default. Learn more about how customized files appear on GitHub.

107 changes: 95 additions & 12 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -3,16 +3,36 @@ talks to daikin altherma via LAN adapter BRP069A61 or BRP069A62

# How to use
## How to install ?
Simply type `pip3 install python-daikin-altherma`
Simply get it from [pypi](https://pypi.org/project/python-daikin-altherma/) by:
`pip3 install python-daikin-altherma`

## How to run
```python3
>>> from daikin_altherma import DaikinAltherma
>>> d = DaikinAltherma('192.168.10.126')
>>> print(f'My outdoor temperature is {d.outdoor_temperature}°C')
My outdoor temperature is 2.0°C
>>> d.print_all_status()
Daikin adapter: 192.168.11.100 BRP069A61
Daikin unit: EAVH16S23DA6V 0
Daikin time: 2023-10-20 18:56:08
Hot water tank:
Current: 48.0°C (target 49.0°C)
Heating enabled: True (Powerful: False)
Heating:
Outdoor temp:14.0°C
Indoor temp: 21.5°C
Heating target: 24.0°C (is heating enabled: True)
Leaving water: 29.0°C
Heating mode: heating
Schedule: {'Mo': {'0000': 18.0, '0600': 20.0, '1200': 22.0, '1500': 20.0, '1800': 18.0}, 'Tu': {'0000': 18.0, '0600': 20.0, '1800': 18.0}, 'We': {'0000': 18.0, '0600': 20.0, '1800': 18.0}, 'Th': {'0000': 18.0, '0600': 20.0, '1200': 22.0, '1500': 20.0, '1800': 18.0}, 'Fr': {'0000': 18.0, '0600': 20.0, '1200': 22.0, '1500': 20.0, '1800': 18.0}, 'Sa': {'0000': 18.0, '0600': 20.0, '1200': 22.0, '1500': 20.0, '1800': 18.0}, 'Su': {'0000': 18.0, '0600': 20.0, '1200': 22.0, '1500': 20.0, '1800': 18.0}}

```

## Schedules
You can set schedules using `set_heating_schedule(schedule)`. Your best bet is to
look at the [example file](example.py).

# Documentation
```
class DaikinAltherma(builtins.object)
Expand All @@ -23,50 +43,113 @@ My outdoor temperature is 2.0°C
| __init__(self, adapter_ip: str)
| Initialize self. See help(type(self)) for accurate signature.
|
| set_heating(self, heating_active: bool)
| print_all_status(self)
|
| set_heating_enabled(self, heating_active: bool)
| Whether to turn the heating on(True) or off(False).
| You can confirm that it works by calling self.power_state
| You can confirm that it works by calling self.is_heating_enabled
|
| set_heating_schedule(self, schedule: dict[str, dict[str, float]])
| Sets the heating schedule for the heating.
|
| set_setpoint_temperature(self, setpoint_temperature_c: float)
| Sets the heating setpoint (target) temperature, in °C
|
| set_tank_heating(self, powerful_active: bool)
| set_tank_heating_enabled(self, powerful_active: bool)
| Whether to turn the water tank heating on(True) or off(False).
| You can confirm that it works by calling self.tank_powerful_state
| You can confirm that it works by calling self.is_tank_heating_enabled
|
| ----------------------------------------------------------------------
| Readonly properties defined here:
|
| adapter_model
| Returns the model of the LAN adapter
| Returns the model of the LAN adapter.
| Ex: BRP069A61
|
| heating_mode
| This function name makes no sense, because it
| returns whether the heat pump is heating or cooling.
|
| indoor_setpoint_temperature
| Returns the indoor setpoint (target) temperature, in °C
|
| indoor_temperature
| Returns the indoor temperature, in °C
|
| indoor_unit_software_version
| Returns the unit software version
|
| indoor_unit_version
| Returns the unit version
|
| is_heating_enabled
| Returns if the unit heating is enabled
|
| is_tank_heating_enabled
| Returns if the tank heating is currently enabled
|
| is_tank_powerful
| Returns if the tank is in powerful state
|
| leaving_water_temperature
| Returns the heating leaving water temperature, in °C
|
| outdoor_temperature
| Returns the outdoor temperature, in °C
|
| outdoor_unit_software_version
| Returns the unit software version
|
| pin_code
| Returns the pin code of the LAN adapter
|
| power_consumption
| Returns the energy consumption in kWh per [D]ay, [W]eek, [M]onth
|
| power_state
| Returns the power state
| remote_setting_version
| Returns the remote console setting version
|
| remote_software_version
| Returns the remote console setting software version
|
| tank_power_state
| Returns the tank power state
| schedule_list_heating
| Returns the Schedule list heating
|
| tank_powerful_state
| Returns the tank powerful state
| schedule_next
| What will happen next the temperature
|
| tank_setpoint_temperature
| Returns the hot water tank setpoint (target) temperature, in °C
|
| tank_temperature
| Returns the hot water tank temperature, in °C
|
| unit_datetime
| Returns the current date of the unit. Takes time to refresh
|
| unit_model
| Returns the model of the heating unit.
| Ex: EAVH16S23DA6V
|
| unit_type
| Returns the type of unit
|
| ----------------------------------------------------------------------
| Data descriptors defined here:
|
| __dict__
| dictionary for instance variables (if defined)
|
| __weakref__
| list of weak references to the object (if defined)
|
| ----------------------------------------------------------------------
| Data and other attributes defined here:
|
| DAYS = ['Mo', 'Tu', 'We', 'Th', 'Fr', 'Sa', 'Su']
|
| UserAgent = 'python-daikin-altherma'
```