The IPEM WebServer Code, includes the below.
WebServer URL Commands. An example is http://ipaddress/pwm-on e.g. http:192.168.0.5/pwm-on
-
/pwm-local - This is Enable PWM to take use Local Power reading from specified variable and output.
-
/pwm-remote - This is Enable PWM to take use Remote Power reading from specified variable and output.
-
/pwm-on - This is Enable PWM to take use Local Power reading from specified variable and output.
-
/pwm-off - This is Turn Off PWM Output
-
/pwm-test - This will turn on a test PWM Loop and output
-
/dac-local - This is Enable DAC to take use Local Power reading from specified variable and output.
-
/dac-remote - This is Enable DAC to take use Remote Power reading from specified variable and output.
-
/dac-on - This is Enable DAC to take use Local Power reading from specified variable and output.
-
/dac-off - This is Turn Off DAC Output
-
/dac-test - This will turn on a test DAC Loop and output
Using this URL structure, you are able to directly control the IPEM board, from the same IP as the OTA, or control from Home Automation, such as Domoticz.
For safety (as we do not now what is connected to thh PWM or DAC Output), the output is initially turned off after any command.
Note: Both PWM and DAC can be turned on at the same time, so a method of MPPT can be created, as an example.
Settings
All values from both PWM and DAC, are configurable within the code. The Output is only sent upon change of variable value. Turning off, will turn the respective output off.
A default maximum power of 4000 Watts is in the formula for range control. So, 0-4000W = 0-100%.
The settings applied upon initialisation are:
- PWM Resolution Bit: 14
- PWM Maximum Resolution: 16383
- DAC Resolution Bit: 8
- DAC Maximum Resolution: 255
The DAC Test Mode includes three modes/options within the code. These will be expanded to URL control too.
- 0 = Dynamic Output based on CT Power.
- 1 = Sinewave (Default 10Hz).
- 2 = Fixed Test Voltage. This being used for calibration etc.
The DAC control includes the ability to Set Fixed DAC Output from Remote Value, or Leave to Dynamic CT Power Values (WIP)
Work is underway, so the WebServer Page will also include additional information / buttons, relating to this.
Additional information, and other technical details on this project, maybe found in the related repository pages.
Repository Folders
- Code (Code examples for Arduino IDE and PlatformIO)
- Datasheets and Information (Component Datasheets, Schematics, Board Layouts, Photos, Technical Documentation)
- Certification (Related Repository Project or Part, Certification Information)
Repository Tabs
- Wiki (Related Repository Wiki pages and Technical User Information)
- Discussions (Related Repository User Discussion Forum)
- Issues (Related Repository Technical Issues and Fixes)
We value our Customers, Users of our designs and STEM Communities, all over the World . Should you have any other questions, or feedback to share to others, please feel free to:
- Visit the related Project plus the related Discussions and Wiki Pages. See tab in each separate repository.
- Project Community Information can be found at https://www.hackster.io/DitroniX
- DitroniX.net Website - Contact Us
- Twitter: https://twitter.com/DitroniX
- Supporting the STEM Projects - BuyMeACoffee
- LinkedIN: https://www.linkedin.com/in/g8puo/
Dave Williams, Eastbourne, UK.
Electronics Engineer | Software Developer | R&D Support | RF Engineering | Product Certification and Testing | STEM Ambassador
Supporting STEM Learning
Life is one long exciting learning curve, help others by setting the seed to knowledge.