Skip to content

A full-body PET scanner using G4 parameterised solid

License

Notifications You must be signed in to change notification settings

DREXX-lab/SimplePetScanner

 
 

Repository files navigation

SimplePetScanner

This project provides basic Geant4 simulation for a PET scanner, and a set of analysis examples that use the output of the simulation.

Installation

Requires Geant4 installation: https://geant4.web.cern.ch/

Once Geant4 is available on your system, be sure to set up the environment as follows:

source $GEANT4_myPath/share/Geant4-*/geant4make/geant4make.sh

Now clone this repository and compile (requires CMake):

git clone https://github.com/bwynneHEP/SimplePetScanner
cd SimplePetScanner
make

Simulation

Run the compiled executable with command line arguments to set the details of the simulation, e.g.:

build/SimplePetScanner -n 1 --gui --detector SiemensBlock --source LinearF18

-n

Set the number of events to simulate.

--gui

Activate the gui (omit this argument to produce output data only).

--detector

Choose a detector geometry (Siemens or Explorer) and the granularity of the detector crystals. Panel, Block and Crystal modes are supported, corresponding to large detectors running the full axial length of the system, axial sengmentation into smaller detector modules, and fully granualar simulation at the level of individual scintillator crystals.

--detectorLengthMM

Set the length of the detector in mm. The actual length in simulation will be rounded up to accommodate the discrete detector modules. Each detector geometry will take their default length unless this argument is specified.

--detectorMaterial

Set the scintillator material used for the detector crystals. LSO, LYSO (with the precise LYSO composition corresponding to the Explorer detector), NaI, BGO and CsF are supported. Each detector geometry will use their default material unless this argument is specified.

--source

Set the radioactive source, either a radioisotope tracer in a capillary (Linear) or the intrinsic detector background. For a linear source, F18 and Zr89 isotopes are supported. For the detector background, the detector geometry (Siemens or Explorer) should be specified, Lu176 decays will be assumed.

--phantomLengthMM

Regardless of the radioactive source, a polyethylene cylindrical phantom will be simulated in the centre of the detector. Set the length of the phantom in mm with this argument. If a linear radioisotope source is selected, the length of the capillary will be equivalent to the length of the phantom.

--outputFileName

Override the default output file name (hits.csv) to allow multiprocessing.

--decayOutputFileName

Create output csv file containing the information about the radioactive decay. For now it includes only the values of the positron range for each event. The file is created only if this argument is specified in the running command.

--randomSeed

Override the default random seed.

Analysis

Example Jupyter notebooks can be found in the analysis directory, along with helper functions. Commands that run the simulation from within the notebooks assume the relative path of the simulation executable, so please launch the notebooks from within the analysis directory.

Acknowledgements

Includes code from https://github.com/katarinazatkova/PET-material-1 and https://gitlab.cern.ch/geant4/geant4/tree/master/examples/basic/B3