You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Detects failures and prevents a failure from constantly recurring.
Implementation
Basic mechanism
Adds circuit breaker in the middle of a client and service.
Circuit breaker monitors failures by tracking the number of failures.
Once the error rate exceeds some threshold, the circuit breaker will trip so that all further calls fail immediately.
States
Circuit breaker retains a state over a series of calls, there are 3 common value:
Closed
This is the normal state. Circuit breaker doesn't intervene calls except counting the number of failures.
Open
Once the error rate exceeds a threshold, the circuit breaker trips and its state will be changed to "Open".
All further calls from client will be failed immediately.
Timeout timer will be started for changing the state from "Open" to "Half open" when timeout.
Half open
Circuit breaker accepts a limited number of calls:
If all those calls are successful, the circuit breaker will change the state to "Closed" and will all the calls as normal.
If any call fails, the circuit breaker will reverts back the state to "Open" and block all the calls.
More Sophisticated Approaches
General
Log all failed calls to enable an administrator to monitor the health of the operation.
Provide a manual option for an administrator to close or open a circuit breaker.
Changes in a circuit breaker’s state should always be logged.
A circuit breaker's current state should be exposed for querying and monitoring.
In the Closed state
Handle different types of errors more specifically.
Check frequency of errors rather than number of errors.
Have different thresholds for different types of errors.
In the Open state
Rather than using a timer to determine when to switch to the Half-Open state, a circuit breaker can instead periodically ping the service to determine whether it's become available again.
Rather than simply failing quickly, a circuit breaker could also record the details of each call to a journal and arrange for these calls to be replayed when the service becomes available.
Pros & Cons
Pros
Prevents a failure from constantly recurring.
Reduce resources tied up in operations which are likely to fail.