ADS1256 sample value error #9

Open
hustlong opened this issue Dec 19, 2020 · 2 comments
Open

ADS1256 sample value error #9

hustlong opened this issue Dec 19, 2020 · 2 comments

Comments

@hustlong
Copy link

I use ads1256 bcm python3 on rasperry4b, with 15000SPS and read data continuous mode.
使用树莓派4b python3 bcm模式, 15k采样率,连续读模式。

there appear some error voltage value sometimes.
经常会出现一些毛刺错误结果。
微信截图_20201219163657

微信截图_20201219163853

so,what is the reason? it is because the board or my program?
所以,到底是什么原因呢,是电路板自身的原因,还是我的程序有问题?

@hustlong
Copy link
Author

微信截图_20201219164023

@astrocyte-medical
Copy link

astrocyte-medical commented Aug 4, 2021

These spikes indicate an incorrect value of the MSB, so they can be due to incorrect t6 and/or t11 delay (see ADS1256 datasheet).