Taking all color channels instead of green only. #47

Open
Exile333 opened this issue Mar 17, 2018 · 3 comments
Open

Taking all color channels instead of green only. #47

Exile333 opened this issue Mar 17, 2018 · 3 comments

Comments

@Exile333
Copy link

Exile333 commented Mar 17, 2018

For all interested - here's the original article: https://dspace.mit.edu/openaccess-disseminate/1721.1/66243
This implementation does not:

  1. use JADE algorithm to recover original independent signals, from which we take second and do the processing via Fourier transform;
  2. use not all face for processing, but only a small part of a forehead (which is probably fine although);
  3. use raw green channel for processing as particularly green channel is the closest one to represent human pulse.

Correct me if I'm wrong.

@Exile333
Copy link
Author

Exile333 commented Mar 17, 2018

UPD:
Sorry for i didn't read the whole readme. It uses other algorithm to process heartrate.
Still for some reason i don't understand why all color channels are used in processing, not just green.

@Exile333 Exile333 changed the title This implementation is fake. Taking all color channels instead of green only. Mar 17, 2018
@osianSmith
Copy link

Hello
This implementation is using photoplethysmography which is the same technology that many smart
devices such as the Apple Watch use. According to apple (easiest description I could find for you) it works like this.

The heart rate sensor in Apple Watch uses what is known as photoplethysmography. This technology, while difficult to pronounce, is based on a very simple fact: Blood is red because it reflects red light and absorbs green light. Apple Watch uses green LED lights paired with light‑sensitive photodiodes to detect the amount of blood flowing through your wrist at any given moment. When your heart beats, the blood flow in your wrist — and the green light absorption — is greater. Between beats, it’s less. By flashing its LED lights hundreds of times per second, Apple Watch can calculate the number of times the heart beats each minute — your heart rate.

@influt
Copy link

influt commented Oct 31, 2018

Hi
Sorry to wake up this thread. The explanation about green light absorption and red light reflection is clear. I'm guessing that Exile333 was referring to this: https://github.com/thearn/webcam-pulse-detector/blob/no_openmdao/lib/processors_noopenmdao.py#L87 . On this line, we are picking means for all 3 channels instead of just green, which probably is a bug.