Tin HiFi T2 Plus

Tin HiFi T2 Plus

See usage instructions for more options and info.

Parametric EQs

In case of using parametric equalizer, apply preamp of -5.7dB and build filters manually with these parameters. The first 5 filters can be used independently. When using independent subset of filters, apply preamp of -5.7 dB.

Type Fc Q Gain
Peaking 23 Hz 1.11 5.3 dB
Peaking 44 Hz 1.78 2.1 dB
Peaking 1558 Hz 2.45 -4.1 dB
Peaking 3163 Hz 1.52 3.5 dB
Peaking 4011 Hz 2.21 2.1 dB
Peaking 246 Hz 1.01 -2.3 dB
Peaking 843 Hz 2.72 1.5 dB
Peaking 5158 Hz 6.21 -1.0 dB
Peaking 11597 Hz 0.77 -4.0 dB
Peaking 18874 Hz 0.12 3.9 dB

Fixed Band EQs

In case of using fixed band (also called graphic) equalizer, apply preamp of -5.8dB (if available) and set gains manually with these parameters.

Type Fc Q Gain
Peaking 31 Hz 1.41 5.4 dB
Peaking 62 Hz 1.41 1.1 dB
Peaking 125 Hz 1.41 -0.6 dB
Peaking 250 Hz 1.41 -2.4 dB
Peaking 500 Hz 1.41 0.2 dB
Peaking 1000 Hz 1.41 -0.1 dB
Peaking 2000 Hz 1.41 -1.9 dB
Peaking 4000 Hz 1.41 5.3 dB
Peaking 8000 Hz 1.41 -1.2 dB
Peaking 16000 Hz 1.41 2.1 dB