@@ -337,8 +337,8 @@ Select option **c** ("c" followed by "Enter") to configure the firmware:
337337
- With a subscription to Fugro AtomiChron, this option allows the individual Galileo clock bias to be preferred over the composite Fugro bias.
338338
- You can enable a preference for either GPS or Galileo. Enabling Galileo will disable GPS.
339339
- **8) Pulse-Per-Second Interval**
340-
- This defines the interval of the PPS signal. The intervals are defined by the mosiac-T firmware. Use "8" and "Enter" to scroll through the intervals.
341-
- "off"
340+
- This defines the interval of the PPS signal. The intervals are defined by the mosiac-T firmware. Use "8" and "Enter" to scroll through the intervals:
341+
- "off"
342342
- "msec10"
343343
- "msec20"
344344
- "msec50"
@@ -359,7 +359,7 @@ Select option **c** ("c" followed by "Enter") to configure the firmware:
359359
- This allows the timing of the PPS signal to be advanced or retarded. The units are nanoseconds.
360360
- **11) Pulse-Per-Second Time Scale**
361361
- This defines which time scale is used to generate the PPS signal.
362-
- "GPS"
362+
- "GPS"
363363
- "Galileo"
364364
- "BeiDou"
365365
- "GLONASS"
@@ -382,7 +382,7 @@ The TCXO frequency control word is saved to NVM once per hour, to allow a quicke
382382

383383
### TCP Server (IPS1)
384384

385-
When **TCP Server (IPS1)** is enabled, the ESP32 serial console is diverted from the CH340 (USB) interface to the mosaic-T COM3 UART interface and daisy chained to the IPS1 TCP server. The configuration menu and debug messages can then be accessed over TCP / Telnet on the chosen port. The CH340 (USB) interface is then no longer active.
385+
When **TCP Server (IPS1)** is enabled, the ESP32 serial console is diverted from the CH340 USB (CONFIG ESP32) interface to the mosaic-T COM3 UART interface and daisy chained to the IPS1 TCP server. The configuration menu and debug messages can then be accessed over TCP / Telnet on the chosen port. The CH340 USB (CONFIG ESP32) interface is then no longer active.
386386

387387
TCP / Telnet is supported over both Ethernet and the Ethernet-over-USB connection. Only one TCP2Way connection is supported.