Meta station engi hv mapping is missing wires. #34344

Open
VerinSenpai opened this issue Jan 9, 2025 · 4 comments
Open

Meta station engi hv mapping is missing wires. #34344

VerinSenpai opened this issue Jan 9, 2025 · 4 comments
Labels
A: Mapping Area: Maps, or tools used for mapping DB: Beginner Friendly Difficulty: Great for beginners. Unambiguous in scope, and explains how to achieve the result. P3: Standard Priority: Default priority for repository items. T: Bugfix Type: Bugs and/or bugfixes

Comments

@VerinSenpai
Copy link

VerinSenpai commented Jan 9, 2025

Description

There is no HV connecting the sides of rad collectors together. Only the south array of collectors is connected to the grid. The north array runs off to connect to gravity and north east solars but has no connection to the SMES bank. The substation powering engineering also has no connection to the load side of the SMES bank for the singulo/ame. This means that if the TEG is running and no other power sources are active, engineering power will eventually die out.

Amending another issue to this post.

In the science arti room, theres two manual valves hooked up to distro into the arti chambers. These should probably have passive gates behind them as it enables accidental plasma leakage into distro.

Reproduction
Load up Meta station.
Examine the HV routing beneath the floor.

Screenshots
{084133AD-1E75-431C-8E65-277A055953D9}
{CFE12109-E396-4DB5-8B76-A328145DE5A4}
{6C7BCD92-3774-420B-B213-5D2FFB986E60}

Edit: View the amendment.

@github-actions github-actions bot added the S: Untriaged Status: Indicates an item has not been triaged and doesn't have appropriate labels. label Jan 9, 2025
@ArtisticRoomba
Copy link
Contributor

this was fixed in hotfix #34256, well aware

@ArtisticRoomba
Copy link
Contributor

This means that if the TEG is running and no other power sources are active, engineering power will eventually die out.

well, someone pointed it out. guess I have to fix it... i'll probably get to it and itll be included for next stable merge

@VerinSenpai
Copy link
Author

VerinSenpai commented Jan 10, 2025

This means that if the TEG is running and no other power sources are active, engineering power will eventually die out.

well, someone pointed it out. guess I have to fix it... i'll probably get to it and itll be included for next stable merge

That'd be great. Also whats the time frame on the hotfixes rolling out? I just noticed the issue today with the north rad array not being connected to anything.

edit: just realized I replied to the wrong comment.

@VerinSenpai
Copy link
Author

I amended another issue to this post regarding distro piping in the arti room.

@beck-thompson beck-thompson added T: Bugfix Type: Bugs and/or bugfixes P3: Standard Priority: Default priority for repository items. DB: Beginner Friendly Difficulty: Great for beginners. Unambiguous in scope, and explains how to achieve the result. A: Mapping Area: Maps, or tools used for mapping and removed S: Untriaged Status: Indicates an item has not been triaged and doesn't have appropriate labels. labels Jan 10, 2025