plc receive function always return empty byte #35
Comments
I had the same issue. It is likely due to the fact that MiniCPS doesn't work with the newest version of cpppo. Although, there has been a commit in the past month which seems to have fixed it but I haven't tested it. To fix the issue, I had to use cpppo's functions directly rather than using MiniCPS's higher level functions. Here is an example to host a value on PLC2 called FIT201 and access it from PLC1:
PLC2_PROTOCOL = {
'name': 'enip',
'mode': 0,
'server': PLC2_SERVER
}
import shlex
import subprocess
from cpppo.server.enip.get_attribute
import proxy_simple
# Start enip server and to host a REAL value, available @22/1/1
tag_string = 'FIT201:2@22/1/1=REAL'
cmd = shlex.split(
'enip_server --print' +
' ' + tag_string
)
client = subprocess.Popen(cmd, shell=False)
from cpppo.server.enip.get_attribute import proxy_simple
from cpppo import logging
# Request value of FIT201 from PLC2
class PLC2Parameters(proxy_simple):
PARAMETERS = dict(proxy_simple.PARAMETERS,
fit201_2 = proxy_simple.parameter('@22/1/1', 'REAL', 'm^3/h'),
)
PLC2_COMMS = PLC2Parameters(host=PLC2_ADDR)
# Get from PLC2
try:
params = PLC2_COMMS.parameter_substitution("fit201_2")
value, = PLC2_COMMS.read(params)
except Exception as exc:
logging.warning("Access to fit201_2 at PLC2 failed: %s", exc)
PLC2_COMMS.close_gateway(exc)
raise
fit201 = float(value[0]) It's janky but it works. Updating hosted values in PLC2's serverAnd if you want to update the values in PLC2 then you can use the following code: via = proxy_simple('192.168.1.20')
fit201_tag = '@22/1/1' Inside the with via: result, = via.read([(fit201_tag + '=(REAL)' + str(fit201), fit201_tag)])
print 'this is the return value: %s' % result If you do this, you might receive an error with plc2.py. If you do, just run the script again, adding an "&" at the end: I know that this answer is long and not perfect so if you need any clarification then do ask! |
this confuses me for a long time |
As the title said, am trying to use the swat example given in examples/swat-s1, but when i try receiving something in plc1 from plc2 it always return an empty byte. I tried sending the tag with
self.send(TAG, VALUE, PLC1_ADDR)
andself.send(TAG, VALUE, PLC2_ADDR)
neither works. I did thesame with receive,self.recieve(TAG, PLC1_ADDR)
andself.recieve(TAG, PLC2_ADDR)
but no luck.From what i understand minicps use cpppo to send/receive stuff. Since i received an empty bytes i cant call
float
on it. It resulted to astr cant be converted to float (which make sense)
I tested it on ubuntu and endeavoros(arch based) but all result in thesame.
Sample output from plc1 terminal
Am really lost