forked from stik79/DeltaPVOutput
-
Notifications
You must be signed in to change notification settings - Fork 11
/
Copy pathDeltaPVOutput.py
executable file
·103 lines (85 loc) · 3.84 KB
/
DeltaPVOutput.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
#A simple script to read values from a delta inverter and post them to
#PVoutput.org
import time, subprocess,serial
from delta30EUG4TRInv import Delta30EU_G4_TR_Inverter
from time import localtime, strftime
from config import Configuration
from mysql import MysqlInserter
#PVOutput.org API Values - UPDATE THESE TO YOURS!
#Array of SystemID's that correlate to the inverter number
#ie. the first systemID will be inverter 1, second inverter 2 etc
#the numebr of systemIDs must still be the same as the number of inverter- even if they
#are empty.
#an empty string means don't individually update this inverter on pvoutput.org - just do the totals
if __name__ == '__main__':
connection = serial.Serial('/dev/ttyUSB0',Configuration.serialBaud, timeout=Configuration.serialTimeoutSecs)
localtime = time.localtime(time.time())
t_date = 'd={0}'.format(strftime('%Y%m%d'))
t_time = 't={0}'.format(strftime('%H:%M'))
totalWh =0
totalACPower =0
totalDCPower =0
avgTempDC=0
validInv =0
for index in range(len(Configuration.SYSTEMIDS)):
inv = Delta30EU_G4_TR_Inverter(Configuration.RS485IDS[index], connection) #init Inverter
#Get the Daily Energy thus far
try:
energyDay = int(inv.call('Energy Day'))
validInv+=1
totalWh+= energyDay
t_energy = 'v1={0}'.format(energyDay)
#instanteous power AC-side
acPower = inv.call('AC Power')
totalACPower+= int(acPower)
t_power = 'v2={0}'.format(acPower)
#instanteous power DC-side
dcPower = inv.call('DC Power')
totalDCPower+=int(dcPower)
#DC Voltage
dcVoltage = inv.call('DC Voltage')
t_volts = 'v6={0}'.format(dcVoltage)
#Temp - this appears to be onboard somewhere not the heatsink
temp = inv.call('Internal Ambient Temperature')
avgTempDC += int(temp)
t_temp = 'v5={0}'.format(temp)
if not Configuration.SYSTEMIDS[index]=="":
#Send it all off to PVOutput.org
cmd = ['/usr/bin/curl',
'-d', t_date,
'-d', t_time,
'-d', t_energy,
'-d', t_power,
'-d', t_volts,
'-d', t_temp,
'-H', 'X-Pvoutput-Apikey: ' + Configuration.APIKEY,
'-H', 'X-Pvoutput-SystemId: ' + Configuration.SYSTEMIDS[index],
'http://pvoutput.org/service/r1/addstatus.jsp']
ret = subprocess.call (cmd)
try:
m = MysqlInserter()
m.insert(Configuration.RS485IDS[index], dcVoltage, dcPower, acPower)
except:
print "Error inserting into mysql"
except:
print "No or failed response from inverter %d - shutdown? No Data sent to PVOutput.org"% (index+1)
if validInv >1 and totalACPower >0:
print "%d awake Inverters" % validInv
avgTempDC=avgTempDC/validInv
t_energy = 'v1={0}'.format(totalWh)
t_power = 'v2={0}'.format(totalACPower)
t_temp = 'v5={0}'.format(avgTempDC)
#Send it all off to PVOutput.org
cmd = ['/usr/bin/curl',
'-d', t_date,
'-d', t_time,
'-d', t_energy,
'-d', t_power,
'-d', t_temp,
'-H', 'X-Pvoutput-Apikey: ' + Configuration.APIKEY,
'-H', 'X-Pvoutput-SystemId: ' + Configuration.TOTALSYSTEMID,
'http://pvoutput.org/service/r1/addstatus.jsp']
ret = subprocess.call (cmd)
else:
print "No response from any inverter - shutdown? No Data sent to PVOutput.org"