Describe the bug
Randomly, approximatly 1x per hour the velodyne driver gives out a single WARN diagnostics message. The point cloud stream is still good. I have a feeling this is a threading/locking issue with the diagnostics updater.
To Reproduce
Run the driver
Record a bagfile for 1 hour or more
Run the following command to figure out if the bug happens rostopic echo -b file.bag /diagnostics/status[0]/message | grep '\w'
In plotjuggler, you can plot Events in window to visually see when the bug occurs.
Expected behavior
The point cloud data stream is good, so I expect the diagnostics to always send out OK.
Additional context
Diagnostics visualized in plotjuggler. I wrote an external diagnostics_updater that listends to the pointcloud data and it never reports a problem. Both diagnostics are visualized below.
This is the full diagnostics message that is produced:
level: 1name: "velodyne_nodelet_manager_driver: velodyne_packets topic status"message: "No data since last update."hardware_id: "Velodyne VLP-16"values:
-
key: "Events in window"value: "90"
-
key: "Events since startup"value: "35120"
-
key: "Duration of window (s)"value: "9.077190"
-
key: "Actual frequency (Hz)"value: "9.914963"
-
key: "Target frequency (Hz)"value: "9.921053"
-
key: "Minimum acceptable frequency (Hz)"value: "4.960526"
-
key: "Maximum acceptable frequency (Hz)"value: "14.881579"
-
key: "Earliest timestamp delay"value: "No data"
-
key: "Latest timestamp delay"value: "No data"
-
key: "Earliest acceptable timestamp delay"value: "-1.000000"
-
key: "Latest acceptable timestamp delay"value: "5.000000"
-
key: "Late diagnostic update count"value: "0"
-
key: "Early diagnostic update count"value: "0"
-
key: "Zero seen diagnostic update count"value: "0"
---
The text was updated successfully, but these errors were encountered:
Sorry it took me so long to get to this. If this issue persists, please try to verify if the drop in data are due to the data stream from the sensor being interrupted (e.g. record a pcap file during a drop-out) or from the driver. Having information about system memory utilization would help too as this could be a memory leak.
The strange thing is that the pointcloud data is still arriving from the ROS driver at the expected rate. The problem is purely in the diagnostics message.
Please complete the following information:
Describe the bug
Randomly, approximatly 1x per hour the velodyne driver gives out a single WARN diagnostics message. The point cloud stream is still good. I have a feeling this is a threading/locking issue with the diagnostics updater.
To Reproduce
rostopic echo -b file.bag /diagnostics/status[0]/message | grep '\w'
Events in window
to visually see when the bug occurs.Expected behavior
The point cloud data stream is good, so I expect the diagnostics to always send out OK.
Additional context
Diagnostics visualized in plotjuggler. I wrote an external diagnostics_updater that listends to the pointcloud data and it never reports a problem. Both diagnostics are visualized below.
This is the full diagnostics message that is produced:
The text was updated successfully, but these errors were encountered: