Notifications
You must be signed in to change notification settings - Fork 120
/
FIBARO- Dimmer
485 lines (440 loc) · 22.5 KB
/
FIBARO- Dimmer
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
/**
* FIBARO Dimmer 2
*
* Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except
* in compliance with the License. You may obtain a copy of the License at:
*
* http://www.apache.org/licenses/LICENSE-2.0
*
* Unless required by applicable law or agreed to in writing, software distributed under the License is distributed
* on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License
* for the specific language governing permissions and limitations under the License.
*
*/
metadata {
definition (name: "Fibaro Dimmer 2 ZW5", namespace: "FibarGroup", author: "Fibar Group") {
capability "Switch"
capability "Switch Level"
capability "Energy Meter"
capability "Power Meter"
capability "Button"
capability "Configuration"
capability "Health Check"
command "reset"
command "refresh"
command "clearError"
attribute "errorMode", "string"
fingerprint mfr: "010F", prod: "0102"
fingerprint deviceId: "0x1101", inClusters:"0x5E,0x86,0x72,0x59,0x73,0x22,0x31,0x32,0x71,0x56,0x98,0x7A,0x20,0x5A,0x85,0x26,0x8E,0x60,0x70,0x75,0x27"
fingerprint deviceId: "0x1101", inClusters:"0x5E,0x86,0x72,0x59,0x73,0x22,0x31,0x32,0x71,0x56,0x7A,0x20,0x5A,0x85,0x26,0x8E,0x60,0x70,0x75,0x27"
}
tiles (scale: 2) {
multiAttributeTile(name:"switch", type: "lighting", width: 3, height: 4, canChangeIcon: false){
tileAttribute ("device.switch", key: "PRIMARY_CONTROL") {
attributeState "off", label: 'Off', action: "on", icon: "https://s3-eu-west-1.amazonaws.com/fibaro-smartthings/dimmer/dimmer0.png", backgroundColor: "#ffffff", nextState:"turningOn"
attributeState "on", label: 'On', action: "off", icon: "https://s3-eu-west-1.amazonaws.com/fibaro-smartthings/dimmer/dimmer100.png", backgroundColor: "#00a0dc", nextState:"turningOff"
attributeState "turningOn", label:'Turning On', action:"off", icon:"https://s3-eu-west-1.amazonaws.com/fibaro-smartthings/dimmer/dimmer50.png", backgroundColor:"#00a0dc", nextState:"turningOff"
attributeState "turningOff", label:'Turning Off', action:"on", icon:"https://s3-eu-west-1.amazonaws.com/fibaro-smartthings/dimmer/dimmer50.png", backgroundColor:"#ffffff", nextState:"turningOn"
}
tileAttribute("device.multiStatus", key:"SECONDARY_CONTROL") {
attributeState("combinedMeter", label:'${currentValue}')
}
tileAttribute ("device.level", key: "SLIDER_CONTROL") {
attributeState "level", action:"switch level.setLevel"
}
}
valueTile("power", "device.power", decoration: "flat", width: 2, height: 2) {
state "power", label:'${currentValue}\nW', action:"refresh"
}
valueTile("energy", "device.energy", decoration: "flat", width: 2, height: 2) {
state "energy", label:'${currentValue}\nkWh', action:"refresh"
}
valueTile("reset", "device.energy", decoration: "flat", width: 2, height: 2) {
state "reset", label:'reset\nkWh', action:"reset"
}
standardTile("errorMode", "device.errorMode", decoration: "flat", width: 2, height: 2) {
state "default", label:'No errors.', action:"clearError", icon: "st.secondary.tools", backgroundColor: "#ffffff"
state "overheat", label:'Overheat!', action:"clearError", icon: "st.secondary.tools", backgroundColor: "#ff0000"
state "surge", label:'Surge!', action:"clearError", icon: "st.secondary.tools", backgroundColor: "#ff0000"
state "voltageDrop", label:'Voltage drop!', action:"clearError", icon: "st.secondary.tools", backgroundColor: "#ff0000"
state "overcurrent", label:'Overcurrent!', action:"clearError", icon: "st.secondary.tools", backgroundColor: "#ff0000"
state "overload", label:'Overload!', action:"clearError", icon: "st.secondary.tools", backgroundColor: "#ff0000"
state "loadError", label:'Load Error!', action:"clearError", icon: "st.secondary.tools", backgroundColor: "#ff0000"
state "hardware", label:'Hardware Error!', action:"clearError", icon: "st.secondary.tools", backgroundColor: "#ff0000"
}
}
preferences {
input (
title: "Fibaro Dimmer 2 ZW5 manual",
description: "Tap to view the manual.",
image: "http://manuals.fibaro.com/wp-content/uploads/2017/02/d2_icon.png",
url: "http://manuals.fibaro.com/content/manuals/en/FGD-212/FGD-212-EN-T-v1.3.pdf",
type: "href",
element: "href"
)
parameterMap().each {
input (
title: "${it.num}. ${it.title}",
description: it.descr,
type: "paragraph",
element: "paragraph"
)
input (
name: it.key,
title: null,
type: it.type,
options: it.options,
range: (it.min != null && it.max != null) ? "${it.min}..${it.max}" : null,
defaultValue: it.def,
required: false
)
}
input ( name: "logging", title: "Logging", type: "boolean", required: false )
}
}
def on() { encap(zwave.basicV1.basicSet(value: 255)) }
def off() { encap(zwave.basicV1.basicSet(value: 0)) }
def setLevel(Integer level, Integer rate = null ) {
logging("${device.displayName} - Executing setLevel( $level, $rate )","info")
if (rate == null) {
encap(zwave.basicV1.basicSet(value: (level > 0) ? level-1 : 0))
} else {
encap(zwave.switchMultilevelV3.switchMultilevelSet(value: (level > 0) ? level-1 : 0, dimmingDuration: rate))
}
}
def reset() {
logging("${device.displayName} - Executing reset()","info")
def cmds = []
cmds << zwave.meterV3.meterReset()
cmds << zwave.meterV3.meterGet(scale: 0)
encapSequence(cmds,1000)
}
def refresh() {
logging("${device.displayName} - Executing refresh()","info")
def cmds = []
cmds << zwave.meterV3.meterGet(scale: 0)
cmds << zwave.sensorMultilevelV5.sensorMultilevelGet()
encapSequence(cmds,1000)
}
def clearError() {
logging("${device.displayName} - Executing clearError()","info")
sendEvent(name: "errorMode", value: "clear")
}
def updated() {
if ( state.lastUpdated && (now() - state.lastUpdated) < 500 ) return
def cmds = []
logging("${device.displayName} - Executing updated()","info")
if (device.currentValue("numberOfButtons") != 5) { sendEvent(name: "numberOfButtons", value: 5) }
runIn(3,"syncStart")
state.lastUpdated = now()
}
private syncStart() {
boolean syncNeeded = false
parameterMap().each {
if(settings."$it.key" != null) {
if (state."$it.key" == null) { state."$it.key" = [value: null, state: "synced"] }
if (state."$it.key".value != settings."$it.key" as Integer || state."$it.key".state in ["notSynced","inProgress"]) {
state."$it.key".value = settings."$it.key" as Integer
state."$it.key".state = "notSynced"
syncNeeded = true
}
}
}
if ( syncNeeded ) {
logging("${device.displayName} - starting sync.", "info")
multiStatusEvent("Sync in progress.", true, true)
syncNext()
}
}
private syncNext() {
logging("${device.displayName} - Executing syncNext()","info")
def cmds = []
for ( param in parameterMap() ) {
if ( state."$param.key"?.value != null && state."$param.key"?.state in ["notSynced","inProgress"] ) {
multiStatusEvent("Sync in progress. (param: ${param.num})", true)
state."$param.key"?.state = "inProgress"
cmds << response(encap(zwave.configurationV2.configurationSet(configurationValue: intToParam(state."$param.key".value, param.size), parameterNumber: param.num, size: param.size)))
cmds << response(encap(zwave.configurationV2.configurationGet(parameterNumber: param.num)))
break
}
}
if (cmds) {
runIn(10, "syncCheck")
sendHubCommand(cmds,1000)
} else {
runIn(1, "syncCheck")
}
}
private syncCheck() {
logging("${device.displayName} - Executing syncCheck()","info")
def failed = []
def incorrect = []
def notSynced = []
parameterMap().each {
if (state."$it.key"?.state == "incorrect" ) {
incorrect << it
} else if ( state."$it.key"?.state == "failed" ) {
failed << it
} else if ( state."$it.key"?.state in ["inProgress","notSynced"] ) {
notSynced << it
}
}
if (failed) {
logging("${device.displayName} - Sync failed! Check parameter: ${failed[0].num}","info")
sendEvent(name: "syncStatus", value: "failed")
multiStatusEvent("Sync failed! Check parameter: ${failed[0].num}", true, true)
} else if (incorrect) {
logging("${device.displayName} - Sync mismatch! Check parameter: ${incorrect[0].num}","info")
sendEvent(name: "syncStatus", value: "incomplete")
multiStatusEvent("Sync mismatch! Check parameter: ${incorrect[0].num}", true, true)
} else if (notSynced) {
logging("${device.displayName} - Sync incomplete!","info")
sendEvent(name: "syncStatus", value: "incomplete")
multiStatusEvent("Sync incomplete! Open settings and tap Done to try again.", true, true)
} else {
logging("${device.displayName} - Sync Complete","info")
sendEvent(name: "syncStatus", value: "synced")
multiStatusEvent("Sync OK.", true, true)
}
}
private multiStatusEvent(String statusValue, boolean force = false, boolean display = false) {
if (!device.currentValue("multiStatus")?.contains("Sync") || device.currentValue("multiStatus") == "Sync OK." || force) {
sendEvent(name: "multiStatus", value: statusValue, descriptionText: statusValue, displayed: display)
}
}
def zwaveEvent(physicalgraph.zwave.commands.configurationv2.ConfigurationReport cmd) {
def paramKey = parameterMap().find( {it.num == cmd.parameterNumber } ).key
logging("${device.displayName} - Parameter ${paramKey} value is ${cmd.scaledConfigurationValue} expected " + state."$paramKey".value, "info")
state."$paramKey".state = (state."$paramKey".value == cmd.scaledConfigurationValue) ? "synced" : "incorrect"
syncNext()
}
def zwaveEvent(physicalgraph.zwave.commands.applicationstatusv1.ApplicationRejectedRequest cmd) {
logging("${device.displayName} - rejected request!","warn")
for ( param in parameterMap() ) {
if ( state."$param.key"?.state == "inProgress" ) {
state."$param.key"?.state = "failed"
break
}
}
}
def zwaveEvent(physicalgraph.zwave.commands.basicv1.BasicReport cmd) {
logging("${device.displayName} - BasicReport received, ignored, value: ${cmd.value}","info")
}
def zwaveEvent(physicalgraph.zwave.commands.switchmultilevelv3.SwitchMultilevelReport cmd) {
logging("${device.displayName} - SwitchMultilevelReport received, value: ${cmd.value}","info")
sendEvent(name: "switch", value: (cmd.value > 0) ? "on" : "off")
sendEvent(name: "level", value: (cmd.value > 0) ? cmd.value+1 : 0)
}
def zwaveEvent(physicalgraph.zwave.commands.sensormultilevelv5.SensorMultilevelReport cmd) {
logging("${device.displayName} - SensorMultilevelReport received, $cmd","info")
if ( cmd.sensorType == 4 ) {
sendEvent(name: "power", value: cmd.scaledSensorValue, unit: "W")
multiStatusEvent("${(device.currentValue("power") ?: "0.0")} W | ${(device.currentValue("energy") ?: "0.00")} kWh")
}
}
def zwaveEvent(physicalgraph.zwave.commands.meterv3.MeterReport cmd) {
logging("${device.displayName} - MeterReport received, value: ${cmd.scaledMeterValue} scale: ${cmd.scale} ep: $ep","info")
switch (cmd.scale) {
case 0:
sendEvent([name: "energy", value: cmd.scaledMeterValue, unit: "kWh"])
break
case 2:
sendEvent([name: "power", value: cmd.scaledMeterValue, unit: "W"])
break
}
multiStatusEvent("${(device.currentValue("power") ?: "0.0")} W | ${(device.currentValue("energy") ?: "0.00")} kWh")
}
def zwaveEvent(physicalgraph.zwave.commands.centralscenev1.CentralSceneNotification cmd) {
logging("${device.displayName} - CentralSceneNotification received, sceneNumber: ${cmd.sceneNumber} keyAttributes: ${cmd.keyAttributes}","info")
log.info cmd
def String action
def Integer button
switch (cmd.sceneNumber as Integer) {
case [10,11,16]: action = "pushed"; button = 1; break
case 14: action = "pushed"; button = 2; break
case [20,21,26]: action = "pushed"; button = 3; break
case 24: action = "pushed"; button = 4; break
case 25: action = "pushed"; button = 5; break
case 12: action = "held"; button = 1; break
case 22: action = "held"; button = 3; break
case 13: action = "released"; button = 1; break
case 23: action = "released"; button = 3; break
}
log.info "button $button $action"
sendEvent(name: "button", value: action, data: [buttonNumber: button], isStateChange: true)
}
def zwaveEvent(physicalgraph.zwave.commands.notificationv3.NotificationReport cmd) {
logging("${device.displayName} - NotificationReport received for ${cmd.event}, parameter value: ${cmd.eventParameter[0]}", "info")
switch (cmd.notificationType) {
case 4:
switch (cmd.event) {
case 0: sendEvent(name: "errorMode", value: "clear"); break;
case [1,2]: sendEvent(name: "errorMode", value: "overheat"); break;
}; break;
case 8:
switch (cmd.event) {
case 0: sendEvent(name: "errorMode", value: "clear"); break;
case 4: sendEvent(name: "errorMode", value: "surge"); break;
case 5: sendEvent(name: "errorMode", value: "voltageDrop"); break;
case 6: sendEvent(name: "errorMode", value: "overcurrent"); break;
case 8: sendEvent(name: "errorMode", value: "overload"); break;
case 9: sendEvent(name: "errorMode", value: "loadError"); break;
}; break;
case 9:
switch (cmd.event) {
case 0: sendEvent(name: "errorMode", value: "clear"); break;
case [1,3]: sendEvent(name: "errorMode", value: "hardware"); break;
}; break;
default: logging("${device.displayName} - Unknown zwaveAlarmType: ${cmd.zwaveAlarmType}","warn");
}
}
def parse(String description) {
def result = []
logging("${device.displayName} - Parsing: ${description}")
if (description.startsWith("Err 106")) {
result = createEvent(
descriptionText: "Failed to complete the network security key exchange. If you are unable to receive data from it, you must remove it from your network and add it again.",
eventType: "ALERT",
name: "secureInclusion",
value: "failed",
displayed: true,
)
} else if (description == "updated") {
return null
} else {
def cmd = zwave.parse(description, cmdVersions())
if (cmd) {
logging("${device.displayName} - Parsed: ${cmd}")
zwaveEvent(cmd)
}
}
}
def zwaveEvent(physicalgraph.zwave.commands.securityv1.SecurityMessageEncapsulation cmd) {
def encapsulatedCommand = cmd.encapsulatedCommand(cmdVersions())
if (encapsulatedCommand) {
logging("${device.displayName} - Parsed SecurityMessageEncapsulation into: ${encapsulatedCommand}")
zwaveEvent(encapsulatedCommand)
} else {
log.warn "Unable to extract Secure command from $cmd"
}
}
def zwaveEvent(physicalgraph.zwave.commands.crc16encapv1.Crc16Encap cmd) {
def version = cmdVersions()[cmd.commandClass as Integer]
def ccObj = version ? zwave.commandClass(cmd.commandClass, version) : zwave.commandClass(cmd.commandClass)
def encapsulatedCommand = ccObj?.command(cmd.command)?.parse(cmd.data)
if (encapsulatedCommand) {
logging("${device.displayName} - Parsed Crc16Encap into: ${encapsulatedCommand}")
zwaveEvent(encapsulatedCommand)
} else {
log.warn "Unable to extract CRC16 command from $cmd"
}
}
def zwaveEvent(physicalgraph.zwave.commands.multichannelv3.MultiChannelCmdEncap cmd) {
def encapsulatedCommand = cmd.encapsulatedCommand(cmdVersions())
if (encapsulatedCommand) {
logging("${device.displayName} - Parsed MultiChannelCmdEncap ${encapsulatedCommand}")
zwaveEvent(encapsulatedCommand, cmd.sourceEndPoint as Integer)
} else {
log.warn "Unable to extract MultiChannel command from $cmd"
}
}
private logging(text, type = "debug") {
if (settings.logging == "true") {
log."$type" text
}
}
private secEncap(physicalgraph.zwave.Command cmd) {
logging("${device.displayName} - encapsulating command using Secure Encapsulation, command: $cmd","info")
zwave.securityV1.securityMessageEncapsulation().encapsulate(cmd).format()
}
private crcEncap(physicalgraph.zwave.Command cmd) {
logging("${device.displayName} - encapsulating command using CRC16 Encapsulation, command: $cmd","info")
zwave.crc16EncapV1.crc16Encap().encapsulate(cmd).format()
}
private multiEncap(physicalgraph.zwave.Command cmd, Integer ep) {
logging("${device.displayName} - encapsulating command using MultiChannel Encapsulation, ep: $ep command: $cmd","info")
zwave.multiChannelV3.multiChannelCmdEncap(destinationEndPoint:ep).encapsulate(cmd)
}
private encap(physicalgraph.zwave.Command cmd, Integer ep) {
encap(multiEncap(cmd, ep))
}
private encap(List encapList) {
encap(encapList[0], encapList[1])
}
private encap(Map encapMap) {
encap(encapMap.cmd, encapMap.ep)
}
private encap(physicalgraph.zwave.Command cmd) {
if (zwaveInfo.zw.contains("s")) {
secEncap(cmd)
} else if (zwaveInfo.cc.contains("56")){
crcEncap(cmd)
} else {
logging("${device.displayName} - no encapsulation supported for command: $cmd","info")
cmd.format()
}
}
private encapSequence(cmds, Integer delay=250) {
delayBetween(cmds.collect{ encap(it) }, delay)
}
private encapSequence(cmds, Integer delay, Integer ep) {
delayBetween(cmds.collect{ encap(it, ep) }, delay)
}
private List intToParam(Long value, Integer size = 1) {
def result = []
size.times {
result = result.plus(0, (value & 0xFF) as Short)
value = (value >> 8)
}
return result
}
private Map cmdVersions() {
[0x5E: 1, 0x86: 1, 0x72: 2, 0x59: 1, 0x73: 1, 0x22: 1, 0x31: 5, 0x32: 3, 0x71: 3, 0x56: 1, 0x98: 1, 0x7A: 2, 0x20: 1, 0x5A: 1, 0x85: 2, 0x26: 3, 0x8E: 2, 0x60: 3, 0x70: 2, 0x75: 2, 0x27: 1]
}
private parameterMap() {[
[key: "autoStepTime", num: 6, size: 2, type: "enum", options: [
1: "10 ms",
2: "20 ms",
3: "30 ms",
4: "40 ms",
5: "50 ms",
10: "100 ms",
20: "200 ms"
], def: "1", min: 0, max: 255 , title: " Automatic control - time of a dimming step", descr: "This parameter defines the time of single dimming step during the automatic control."],
[key: "manualStepTime", num: 8, size: 2, type: "enum", options: [
1: "10 ms",
2: "20 ms",
3: "30 ms",
4: "40 ms",
5: "50 ms",
10: "100 ms",
20: "200 ms"
], def: "5", min: 0, max: 255 , title: "Manual control - time of a dimming step", descr: "This parameter defines the time of single dimming step during the manual control."],
[key: "autoOff", num: 10, size: 2, type: "number", def: 0, min: 0, max: 32767 , title: "Timer functionality (auto - off)",
descr: "This parameter allows to automatically switch off the device after specified time from switching on the light source. It may be useful when the Dimmer 2 is installed in the stairway. (1-32767 sec)"],
[key: "autoCalibration", num: 13, size: 1, type: "enum", options: [
0: "readout",
1: "force auto-calibration of the load without FIBARO Bypass 2",
2: "force auto-calibration of the load with FIBARO Bypass 2"
], def: "0", min: 0, max: 2 , title: "Force auto-calibration", descr: "Changing value of this parameter will force the calibration process. During the calibration parameter is set to 1 or 2 and switched to 0 upon completion."],
[key: "switchType", num: 20, size: 1, type: "enum", options: [
0: "momentary switch",
1: "toggle switch",
2: "roller blind switch"
], def: "0", min: 0, max: 2 , title: "Switch type", descr: "Choose between momentary, toggle and roller blind switch. "],
[key: "threeWaySwitch", num: 26, size: 1, type: "enum", options: [
0: "disabled",
1: "enabled"
], def: "0", min: 0, max: 1 , title: "The function of 3-way switch", descr: "Switch no. 2 controls the Dimmer 2 additionally (in 3-way switch mode). Function disabled for parameter 20 set to 2 (roller blind switch)."],
[key: "sceneActivation", num: 28, size: 1, type: "enum", options: [
0: "disabled",
1: "enabled"
], def: "0", min: 0, max: 1 , title: "Scene activation functionality", descr: "SCENE ID depends on the switch type configurations."],
[key: "loadControllMode", num: 30, size: 1, type: "enum", options: [
0: "forced leading edge control",
1: "forced trailing edge control",
2: "control mode selected automatically (based on auto-calibration)"
], def: "2", min: 0, max: 2 , title: "Load control mode", descr: "This parameter allows to set the desired load control mode. The device automatically adjusts correct control mode, but the installer may force its change using this parameter."],
[key: "levelCorrection", num: 38, size: 2, type: "number", def: 255, min: 0, max: 255 , title: "Brightness level correction for flickering loads",
descr: "Correction reduces spontaneous flickering of some capacitive load (e.g. dimmable LEDs) at certain brightness levels in 2-wire installation. In countries using ripple-control, correction may cause changes in brightness. In this case it is necessary to disable correction or adjust time of correction for flickering loads. (1-254 – duration of correction in seconds. For further information please see the manual)"]
]}