@@ -65,17 +65,22 @@ In this step, you will mount and connect all the wiring and pneumatic tubing.
6565
![Looping zip tie](images/zip-tie-1.JPG)
6666
![Looping second zip tie](images/zip-tie-2.JPG)
6767

68-
16. Find the cable labeled `LM`, route it over the top of the Z motor, and secure it in place with the zip tie on the left side of the X gantry.
68+
16. Find the cable labeled `LM`, route it over the top of the Z motor, and **loosely** secure the zip tie on the left side of the X gantry.
69+
6970
![LM cable](images/zip-lh-1.JPG)
70-
![LM cable secured](images/zip-lh-2.JPG)
71+
72+
!!! danger "Secure zip tie loosely"
73+
When tightening the zip tie, do **not** tighten it fully. Tighten until there's about a 15mm diameter opening as shown below. If the zip tie is tightened too tightly, it can cause excessive wear to the cabling.
74+
75+
![LM cable secured](images/loose-zip.jpg)
7176

7277
17. Fit a zip tie through the outer slot on the left Z gantry.
7378
![Zip tie installed into Z gantry](images/zip-lh-3.JPG)
7479

75-
18. Plug the cable labeled `LM` into the left motor on the X gantry. This cable is inserted from the bottom.
80+
1. Plug the cable labeled `LM` into the left motor on the X gantry. This cable is inserted from the bottom.
7681
![Left motor cable plugged in](images/plug-lh.JPG)
7782

78-
19. Tighten left Z gantry zip tie to secure the LM cable in place.
83+
1. Tighten left Z gantry zip tie to secure the LM cable in place.
7984

8085
![Zip tie securing left motor cable](images/zip-lh-4.JPG)
8186

@@ -84,15 +89,19 @@ In this step, you will mount and connect all the wiring and pneumatic tubing.
8489

8590
![incorrect cable mounting](images/incorrect-cable.jpg)
8691

87-
20. Find the cable labeled `RM` and secure it in place using the zip tie on the right side of the X gantry.
88-
![Secured RM cable with a zip tie](images/zip-rh-2.JPG)
92+
2. Find the cable labeled `RM` and secure it in place using the zip tie on the right side of the X gantry.
93+
94+
!!! danger "Secure zip tie loosely"
95+
When tightening the zip tie, do **not** tighten it fully. Tighten until there's about a 15mm diameter opening as shown below. If the zip tie is tightened too tightly, it can cause excessive wear to the cabling.
96+
97+
![LM cable secured](images/loose-zip-right.jpg)
8998

90-
21. Fit a zip tie through the outer slot on the right Z gantry.
99+
3. Fit a zip tie through the outer slot on the right Z gantry.
91100

92-
22. Plug the cable labeled `RM` into the right motor on the X gantry. This cable is inserted from the bottom.
101+
4. Plug the cable labeled `RM` into the right motor on the X gantry. This cable is inserted from the bottom.
93102
![Plug in Right motor cable](images/plug-rh.JPG)
94103

95-
23. Tighten the right Z gantry zip tie to secure the RM cable in place.
104+
5. Tighten the right Z gantry zip tie to secure the RM cable in place.
96105

97106
![Right motor cable secured with zip tie](images/zip-rh-3.JPG)
98107

@@ -101,18 +110,18 @@ In this step, you will mount and connect all the wiring and pneumatic tubing.
101110

102111
![incorrect cable mounting](images/incorrect-cable.jpg)
103112

104-
24. Trim the excess zip ties from the LM and RM cables.
113+
6. Trim the excess zip ties from the LM and RM cables.
105114
![Clipping zip ties](images/lh-trim.JPG)
106115
![Motor cables connected](images/head-trim.JPG)
107116

108-
25. Find the two pieces of tubing labeled `LH` and `RH`, and insert `LH` into the left motor, and `RH` into the right motor. Make sure that the tubing is in between the `LH` and `RH` cable harness going to the motors as shown in the image below.
117+
7. Find the two pieces of tubing labeled `LH` and `RH`, and insert `LH` into the left motor, and `RH` into the right motor. Make sure that the tubing is in between the `LH` and `RH` cable harness going to the motors as shown in the image below.
109118
![LH and RH tubing](images/tubing.JPG)
110119
![LH and RH tubing installed](images/tubing-inserted.JPG)
111120

112121
!!! Note
113122
If you ever need to remove the tubing, press down on the blue plastic circle while pulling upward on the tubing.
114123

115-
26. Your X gantry should look like the image below.
124+
8. Your X gantry should look like the image below.
116125
![Final X gantry](images/finished-head.JPG)
117126

118127
1. Take the print attached to the wire exiting from the middle of the cable chain, and align it with the back of the X motor as shown in the image below.

0 commit comments