Notifications
You must be signed in to change notification settings - Fork 0
/
sdfobject-load_control.swagger.json
154 lines (154 loc) · 4.39 KB
/
sdfobject-load_control.swagger.json
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
{
"swagger": "2.0",
"info": {
"title": "OMA/IPSO Load Control (Object ID 3310)",
"version": "2022-02-22",
"license": {
"name": "BSD-3-Clause",
"x-copyright": "Copyright 2019 Open Mobile Alliance."
}
},
"schemes": [
"http"
],
"consumes": [
"application/json"
],
"produces": [
"application/json"
],
"paths": {
"/Omaipsoloadcontrolobjectid3310ResURI": {
"get": {
"description": " This Object is used for demand-response load control and other load control in automation application (not limited to power).",
"parameters": [
{
"$ref": "#/parameters/interface"
}
],
"responses": {
"200": {
"description": "",
"schema": {
"$ref": "#/definitions/Omaipsoloadcontrolobjectid3310"
}
}
}
}
}
},
"parameters": {
"interface": {
"in": "query",
"name": "if",
"type": "string",
"enum": [
"oic.if.s",
"oic.if.baseline"
]
}
},
"definitions": {
"Omaipsoloadcontrolobjectid3310": {
"properties": {
"rt": {
"description": "The Resource Type.",
"items": {
"enum": [
"oic.r.o.load.control"
],
"type": "string"
},
"minItems": 1,
"uniqueItems": true,
"readOnly": true,
"type": "array"
},
"n": {
"$ref": "https://openconnectivityfoundation.github.io/core/schemas/oic.common.properties.core-schema.json#/definitions/n"
},
"if": {
"description": "The OCF Interface set supported by this Resource.",
"items": {
"enum": [
"oic.if.s",
"oic.if.baseline"
],
"type": "string"
},
"minItems": 1,
"uniqueItems": true,
"readOnly": true,
"type": "array"
},
"Event_Identifier": {
"description": "The event identifier as a string.",
"x-label": "Event Identifier",
"type": "string"
},
"Start_Time": {
"description": "Time when the event started.",
"x-label": "Start Time",
"x-sdfType": "unix-time",
"type": "number"
},
"Duration_In_Min": {
"description": "The duration of the event in minutes.",
"x-label": "Duration In Min",
"type": "integer",
"x-unit": "min"
},
"Criticality_Level": {
"description": "The criticality of the event. The device receiving the event will react in an appropriate fashion for the device.",
"x-label": "Criticality Level",
"maximum": 3,
"minimum": 0,
"type": "integer"
},
"Avg_Load_AdjPct": {
"description": "Defines the maximum energy usage of the receiving device, as a percentage of the device's normal maximum energy usage.",
"x-label": "Avg Load AdjPct",
"maximum": 100,
"minimum": 0,
"type": "integer",
"x-unit": "/100"
},
"Duty_Cycle": {
"description": "Defines the duty cycle for the load control event, i.e, what percentage of time the receiving device is allowed to be on.",
"x-label": "Duty Cycle",
"maximum": 100,
"minimum": 0,
"type": "integer",
"x-unit": "/100"
},
"Application_Type": {
"description": "The application type of the sensor or actuator as a string depending on the use case.",
"x-label": "Application Type",
"type": "string"
},
"Timestamp": {
"description": "The timestamp of when the measurement was performed.",
"x-label": "Timestamp",
"x-sdfType": "unix-time",
"type": "number",
"readOnly": true
},
"Fractional_Timestamp": {
"description": "Fractional part of the timestamp when sub-second precision is used (e.g., 0.23 for 230 ms).",
"x-label": "Fractional Timestamp",
"maximum": 1,
"minimum": 0,
"type": "number",
"x-unit": "s",
"readOnly": true
}
},
"type": "object",
"required": [
"Event_Identifier",
"Start_Time",
"Duration_In_Min"
]
}
}
}