From 35110d7962cb4f51cb426159f93b76095a7147e6 Mon Sep 17 00:00:00 2001 From: Oliver Gorwits Date: Wed, 16 Aug 2023 22:35:46 +0100 Subject: [PATCH] #195 update fortiswitch mib --- EXTRAS/reports/all | 79 +++++++++ EXTRAS/reports/fortinet | 161 +++++++++++++++++ fortinet/fortinet-fortiswitch-mib.mib | 244 ++++++++++++++++++++++++-- 3 files changed, 474 insertions(+), 10 deletions(-) diff --git a/EXTRAS/reports/all b/EXTRAS/reports/all index 8179e98d0..8f38fbb1c 100644 --- a/EXTRAS/reports/all +++ b/EXTRAS/reports/all @@ -510125,6 +510125,27 @@ fsTrapPrefix(0) type=0 fsTrapMemberDown(703) type=21 fsTrapMemberUp(704) type=21 + fsTrapLlvViolation(705) type=21 + fsTrapLearningEvent(706) type=21 + fsTrapSensorFault(707) type=21 + fsTrapSensorAlarm(708) type=21 + fsTrapFanDetect(709) type=21 + fsTrapPsuStatus(710) type=21 + fsTrapIpConflict(801) type=21 + fsTrapTrunkMemberHBOutOfSync(802) type=21 + fsTrapObjects(1) type=0 + fsLlvTrapMsg(1) type=2 hint=255a + fsLearningTrapVid(2) type=3 + fsLearningTrapType(3) type=3 + fsSensorName(4) type=2 hint=255a + fsSensorType(5) type=3 + fsSensorIdx(6) type=3 + fsSensorFanEventType(7) type=3 + fsSensorPsuEventType(8) type=3 + fsAlarmEventType(9) type=3 + fsAlarmThresholdValue(10) type=3 + fsAlarmThresholdUnits(11) type=3 + fsIpAddress(12) type=5 fsTrunkMemPrefix(3) type=0 fsTrunkMember(1) type=2 hint=255a fsSystem(4) type=0 @@ -510135,6 +510156,64 @@ fsSysMemCapacity(4) type=7 fsSysDiskUsage(5) type=7 fsSysDiskCapacity(6) type=7 + fsModel(5) type=0 + fs108d(1081) type=0 + s108en(1082) type=0 + s108ep(1083) type=0 + s108ef(1084) type=0 + s108dv(1085) type=0 + s108fn(1086) type=0 + s108fp(1087) type=0 + s108ff(1088) type=0 + sr12dp(1121) type=0 + s124dn(1241) type=0 + s124dp(1242) type=0 + sr24dn(1243) type=0 + s124en(1244) type=0 + s124ep(1245) type=0 + s124ef(1246) type=0 + s148en(1247) type=0 + s148ep(1248) type=0 + s124ff(1249) type=0 + s148fn(1484) type=0 + s148fp(1485) type=0 + s148ff(1486) type=0 + fs224d(2241) type=0 + s224df(2242) type=0 + s224en(2243) type=0 + s224ep(2244) type=0 + s248dp(2481) type=0 + s248df(2482) type=0 + s248dn(2483) type=0 + s248ef(2484) type=0 + s248ep(2485) type=0 + s424dn(4241) type=0 + s424dp(4242) type=0 + s424df(4243) type=0 + s448dn(4482) type=0 + s448df(4483) type=0 + s448dp(4484) type=0 + s448en(4485) type=0 + s448ep(4486) type=0 + s448ef(4487) type=0 + s524df(5241) type=0 + s524dn(5242) type=0 + s548df(5481) type=0 + s548dn(5482) type=0 + fs1d24(10241) type=0 + fs1e24(10242) type=0 + st1e24(10243) type=0 + fs1d48(10481) type=0 + fs1e48(10482) type=0 + s124fn(12410) type=0 + s124fp(12411) type=0 + fs3d32(30321) type=0 + fs3e32(30322) type=0 + s424en(42401) type=0 + s424ep(42402) type=0 + s424ef(42403) type=0 + s424ei(42404) type=0 + s426ef(42405) type=0 fsMibConformance(100) type=0 fsNotificationGroup(1) type=23 fsSystemObjectGroup(2) type=22 diff --git a/EXTRAS/reports/fortinet b/EXTRAS/reports/fortinet index 647b70d11..6413ac8f6 100644 --- a/EXTRAS/reports/fortinet +++ b/EXTRAS/reports/fortinet @@ -77,6 +77,88 @@ snmpEnableAuthenTraps(30) type=3 snmpSilentDrops(31) type=6 snmpProxyDrops(32) type=6 + dot1dBridge(17) type=24 + dot1dNotifications(0) type=0 + newRoot(1) type=21 + topologyChange(2) type=21 + dot1dBase(1) type=0 + dot1dBaseBridgeAddress(1) type=2 hint=1x: + dot1dBaseNumPorts(2) type=16 units=ports + dot1dBaseType(3) type=3 + dot1dBasePortTable(4) type=0 + dot1dBasePortEntry(1) type=0 + dot1dBasePort(1) type=16 + dot1dBasePortIfIndex(2) type=16 hint=d + dot1dBasePortCircuit(3) type=1 + dot1dBasePortDelayExceededDiscards(4) type=6 + dot1dBasePortMtuExceededDiscards(5) type=6 + dot1dStp(2) type=0 + dot1dStpProtocolSpecification(1) type=3 + dot1dStpPriority(2) type=16 + dot1dStpTimeSinceTopologyChange(3) type=8 units=centi-seconds + dot1dStpTopChanges(4) type=6 + dot1dStpDesignatedRoot(5) type=2 + dot1dStpRootCost(6) type=16 + dot1dStpRootPort(7) type=16 + dot1dStpMaxAge(8) type=16 hint=d units=centi-seconds + dot1dStpHelloTime(9) type=16 hint=d units=centi-seconds + dot1dStpHoldTime(10) type=16 units=centi-seconds + dot1dStpForwardDelay(11) type=16 hint=d units=centi-seconds + dot1dStpBridgeMaxAge(12) type=16 hint=d units=centi-seconds + dot1dStpBridgeHelloTime(13) type=16 hint=d units=centi-seconds + dot1dStpBridgeForwardDelay(14) type=16 hint=d units=centi-seconds + dot1dStpPortTable(15) type=0 + dot1dStpPortEntry(1) type=0 + dot1dStpPort(1) type=16 + dot1dStpPortPriority(2) type=16 + dot1dStpPortState(3) type=3 + dot1dStpPortEnable(4) type=3 + dot1dStpPortPathCost(5) type=16 + dot1dStpPortDesignatedRoot(6) type=2 + dot1dStpPortDesignatedCost(7) type=16 + dot1dStpPortDesignatedBridge(8) type=2 + dot1dStpPortDesignatedPort(9) type=2 + dot1dStpPortForwardTransitions(10) type=6 + dot1dStpPortPathCost32(11) type=16 + dot1dSr(3) type=0 + dot1dTp(4) type=0 + dot1dTpLearnedEntryDiscards(1) type=6 + dot1dTpAgingTime(2) type=16 units=seconds + dot1dTpFdbTable(3) type=0 + dot1dTpFdbEntry(1) type=0 + dot1dTpFdbAddress(1) type=2 hint=1x: + dot1dTpFdbPort(2) type=16 + dot1dTpFdbStatus(3) type=3 + dot1dTpPortTable(4) type=0 + dot1dTpPortEntry(1) type=0 + dot1dTpPort(1) type=16 + dot1dTpPortMaxInfo(2) type=16 units=bytes + dot1dTpPortInFrames(3) type=6 units=frames + dot1dTpPortOutFrames(4) type=6 units=frames + dot1dTpPortInDiscards(5) type=6 units=frames + dot1dStatic(5) type=0 + dot1dStaticTable(1) type=0 + dot1dStaticEntry(1) type=0 + dot1dStaticAddress(1) type=2 hint=1x: + dot1dStaticReceivePort(2) type=16 + dot1dStaticAllowedToGoTo(3) type=2 + dot1dStaticStatus(4) type=3 + dot1dConformance(8) type=0 + dot1dGroups(1) type=0 + dot1dBaseBridgeGroup(1) type=22 + dot1dBasePortGroup(2) type=22 + dot1dStpBridgeGroup(3) type=22 + dot1dStpPortGroup(4) type=22 + dot1dStpPortGroup2(5) type=22 + dot1dStpPortGroup3(6) type=22 + dot1dTpBridgeGroup(7) type=22 + dot1dTpFdbGroup(8) type=22 + dot1dTpGroup(9) type=22 + dot1dStaticGroup(10) type=22 + dot1dNotificationGroup(11) type=23 + dot1dCompliances(2) type=0 + bridgeCompliance1493(1) type=26 + bridgeCompliance4188(2) type=26 ianaifType(30) type=24 ifMIB(31) type=24 ifMIBObjects(1) type=0 @@ -2253,6 +2335,27 @@ fsTrapPrefix(0) type=0 fsTrapMemberDown(703) type=21 fsTrapMemberUp(704) type=21 + fsTrapLlvViolation(705) type=21 + fsTrapLearningEvent(706) type=21 + fsTrapSensorFault(707) type=21 + fsTrapSensorAlarm(708) type=21 + fsTrapFanDetect(709) type=21 + fsTrapPsuStatus(710) type=21 + fsTrapIpConflict(801) type=21 + fsTrapTrunkMemberHBOutOfSync(802) type=21 + fsTrapObjects(1) type=0 + fsLlvTrapMsg(1) type=2 hint=255a + fsLearningTrapVid(2) type=3 + fsLearningTrapType(3) type=3 + fsSensorName(4) type=2 hint=255a + fsSensorType(5) type=3 + fsSensorIdx(6) type=3 + fsSensorFanEventType(7) type=3 + fsSensorPsuEventType(8) type=3 + fsAlarmEventType(9) type=3 + fsAlarmThresholdValue(10) type=3 + fsAlarmThresholdUnits(11) type=3 + fsIpAddress(12) type=5 fsTrunkMemPrefix(3) type=0 fsTrunkMember(1) type=2 hint=255a fsSystem(4) type=0 @@ -2263,6 +2366,64 @@ fsSysMemCapacity(4) type=7 fsSysDiskUsage(5) type=7 fsSysDiskCapacity(6) type=7 + fsModel(5) type=0 + fs108d(1081) type=0 + s108en(1082) type=0 + s108ep(1083) type=0 + s108ef(1084) type=0 + s108dv(1085) type=0 + s108fn(1086) type=0 + s108fp(1087) type=0 + s108ff(1088) type=0 + sr12dp(1121) type=0 + s124dn(1241) type=0 + s124dp(1242) type=0 + sr24dn(1243) type=0 + s124en(1244) type=0 + s124ep(1245) type=0 + s124ef(1246) type=0 + s148en(1247) type=0 + s148ep(1248) type=0 + s124ff(1249) type=0 + s148fn(1484) type=0 + s148fp(1485) type=0 + s148ff(1486) type=0 + fs224d(2241) type=0 + s224df(2242) type=0 + s224en(2243) type=0 + s224ep(2244) type=0 + s248dp(2481) type=0 + s248df(2482) type=0 + s248dn(2483) type=0 + s248ef(2484) type=0 + s248ep(2485) type=0 + s424dn(4241) type=0 + s424dp(4242) type=0 + s424df(4243) type=0 + s448dn(4482) type=0 + s448df(4483) type=0 + s448dp(4484) type=0 + s448en(4485) type=0 + s448ep(4486) type=0 + s448ef(4487) type=0 + s524df(5241) type=0 + s524dn(5242) type=0 + s548df(5481) type=0 + s548dn(5482) type=0 + fs1d24(10241) type=0 + fs1e24(10242) type=0 + st1e24(10243) type=0 + fs1d48(10481) type=0 + fs1e48(10482) type=0 + s124fn(12410) type=0 + s124fp(12411) type=0 + fs3d32(30321) type=0 + fs3e32(30322) type=0 + s424en(42401) type=0 + s424ep(42402) type=0 + s424ef(42403) type=0 + s424ei(42404) type=0 + s426ef(42405) type=0 fsMibConformance(100) type=0 fsNotificationGroup(1) type=23 fsSystemObjectGroup(2) type=22 diff --git a/fortinet/fortinet-fortiswitch-mib.mib b/fortinet/fortinet-fortiswitch-mib.mib index 82cac10ca..a79ff2552 100644 --- a/fortinet/fortinet-fortiswitch-mib.mib +++ b/fortinet/fortinet-fortiswitch-mib.mib @@ -15,16 +15,19 @@ IMPORTS FROM FORTINET-CORE-MIB sysName FROM SNMPv2-MIB + ifName + FROM IF-MIB MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP FROM SNMPv2-CONF - Gauge32, MODULE-IDENTITY, - NOTIFICATION-TYPE, OBJECT-TYPE + Gauge32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE, IpAddress FROM SNMPv2-SMI DisplayString - FROM SNMPv2-TC; + FROM SNMPv2-TC + dot1dTpFdbAddress, dot1dTpFdbPort + FROM BRIDGE-MIB; fnFortiSwitchMib MODULE-IDENTITY - LAST-UPDATED "201109280000Z" + LAST-UPDATED "202204010000Z" ORGANIZATION "Fortinet Technologies, Inc." CONTACT-INFO @@ -34,9 +37,9 @@ fnFortiSwitchMib MODULE-IDENTITY http://www.fortinet.com" DESCRIPTION "MIB module for Fortinet FortiSwitch devices." - REVISION "201109280000Z" + REVISION "202204010000Z" DESCRIPTION - "Initial version of FORTINET-FORTISWITCH-MIB." + "Updated version of FORTINET-FORTISWITCH-MIB." ::= { fortinet 106 } -- @@ -59,10 +62,6 @@ fsSysSerial OBJECT-TYPE in the ENTITY-MIB tables for the base entity." ::= { fsSys 1 } --- --- fortinet.fnFortiSwitchMib.fsModel --- - -- -- fortinet.fnFortiSwitchMib.fsTraps -- @@ -73,6 +72,105 @@ fsTraps OBJECT IDENTIFIER fsTrapPrefix OBJECT IDENTIFIER ::= { fsTraps 0 } +fsTrapObjects OBJECT IDENTIFIER + ::= { fsTraps 1 } + +fsLlvTrapMsg OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Message associated with a learning limit violation." + ::= { fsTrapObjects 1 } + +fsLearningTrapVid OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "VLAN ID associated with a MAC learning event." + ::= { fsTrapObjects 2 } + +fsLearningTrapType OBJECT-TYPE + SYNTAX INTEGER { add(1), delete(2), movefrom(3), moveto(4) } + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Type associated with a MAC learning event (add/delete/movefrom/moveto)." + ::= { fsTrapObjects 3 } + +fsSensorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Name of the sensor associated with a trap message." + ::= { fsTrapObjects 4 } + +fsSensorType OBJECT-TYPE + SYNTAX INTEGER { temperature(1), poe(2), cpu(3), memory(4), disk(6) } + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Type of sensor associated with a trap message (temperature/PoE/CPU/memory/disk)." + ::= { fsTrapObjects 5 } + +fsSensorIdx OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Index of the sensor associated with a trap message." + ::= { fsTrapObjects 6 } + +fsSensorFanEventType OBJECT-TYPE + SYNTAX INTEGER { detected(1), undetected(2), resumed(3), failure(4)} + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Type of event associated with the fan trap message (detected/undetected/resumed/failure)." + ::= { fsTrapObjects 7 } + +fsSensorPsuEventType OBJECT-TYPE + SYNTAX INTEGER { up(1), connected(2), good(3), down(4), disconnected(5), bad(6)} + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Type of event associated with the PSU trap message (up/connected/good/down/disconnected/bad)." + ::= { fsTrapObjects 8 } + +fsAlarmEventType OBJECT-TYPE + SYNTAX INTEGER { inrange(1), warning(2), outofrange(3), cleared(4) } + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Type of event associated with the alarm trap message (inrange/warning/outofrange/cleared)." + ::= { fsTrapObjects 9 } + +fsAlarmThresholdValue OBJECT-TYPE + SYNTAX INTEGER + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Threshold value." + ::= { fsTrapObjects 10 } + +fsAlarmThresholdUnits OBJECT-TYPE + SYNTAX INTEGER { celcius(1), watts(2), percentage(3), unknown(4) } + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Type of units associated with this threshold value (celcius/watts/percentage/unknown)." + ::= { fsTrapObjects 11 } + +fsIpAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "IP address associated with a trap message (e.g. IP Conflict)." + ::= { fsTrapObjects 12 } + -- -- fortinet.fnFortiSwitchMib.fsTrunkMemPrefix -- @@ -102,6 +200,62 @@ fsTrapMemberUp NOTIFICATION-TYPE "A trunk member has joined this trunk" ::= { fsTrapPrefix 704 } +fsTrapLlvViolation NOTIFICATION-TYPE + OBJECTS { fnSysSerial, sysName, fsLlvTrapMsg } + STATUS current + DESCRIPTION + "Trap messages for learning limit violations." + ::= { fsTrapPrefix 705 } + +fsTrapLearningEvent NOTIFICATION-TYPE + OBJECTS { fnSysSerial, sysName, dot1dTpFdbAddress, fsLearningTrapVid, dot1dTpFdbPort, fsLearningTrapType } + STATUS current + DESCRIPTION + "A new MAC address learning event occurred (add/delete/move)." + ::= { fsTrapPrefix 706 } + +fsTrapSensorFault NOTIFICATION-TYPE + OBJECTS { fnSysSerial, sysName, fsSensorName, fsSensorType } + STATUS current + DESCRIPTION + "Trap message indicates that a faulty sensor was detected." + ::= { fsTrapPrefix 707 } + +fsTrapSensorAlarm NOTIFICATION-TYPE + OBJECTS { fnSysSerial, sysName, fsSensorName, fsSensorType, fsAlarmEventType, fsAlarmThresholdValue, fsAlarmThresholdUnits } + STATUS current + DESCRIPTION + "Trap messages for temperature, PoE, CPU, memory, and disk sensor alarms." + ::= { fsTrapPrefix 708 } + +fsTrapFanDetect NOTIFICATION-TYPE + OBJECTS { fnSysSerial, sysName, fsSensorIdx, fsSensorFanEventType } + STATUS current + DESCRIPTION + "Trap message associated with fan sensor detection." + ::= { fsTrapPrefix 709 } + +fsTrapPsuStatus NOTIFICATION-TYPE + OBJECTS { fnSysSerial, sysName, fsSensorIdx, fsSensorPsuEventType } + STATUS current + DESCRIPTION + "Trap message associated with PSU status changes." + ::= { fsTrapPrefix 710 } + +fsTrapIpConflict NOTIFICATION-TYPE + OBJECTS { fnSysSerial, sysName, fsIpAddress, ifname } + STATUS current + DESCRIPTION + "Trap message associated with IP Conflict Detection." + ::= { fsTrapPrefix 801 } + +fsTrapTrunkMemberHBOutOfSync NOTIFICATION-TYPE + OBJECTS { fnSysSerial, sysName, ifName, ifName } + STATUS current + DESCRIPTION + "Trap message indicates a trunk member HB is out of sync (trunk = ifName1, member = ifName2)." + ::= { fsTrapPrefix 802 } + -- -- fortinet.fnFortiSwitchMib.fsSystem -- @@ -160,6 +314,76 @@ fsSysDiskCapacity OBJECT-TYPE "Total hard disk capacity (KB), if disk is present" ::= { fsSystemInfo 6 } + + +-- +-- fortinet.fnFortiSwitchMib.fsModel +-- + +fsModel OBJECT IDENTIFIER ::= { fnFortiSwitchMib 5 } + +-- fsModel start + +s424df OBJECT IDENTIFIER ::= { fsModel 4243} -- FortiSwitch-424D-FPOE +fs108d OBJECT IDENTIFIER ::= { fsModel 1081} -- FortiSwitch-108D-POE +s124fp OBJECT IDENTIFIER ::= { fsModel 12411} -- FortiSwitch-124F-POE +fs224d OBJECT IDENTIFIER ::= { fsModel 2241} -- FortiSwitch-224D-POE +s108fn OBJECT IDENTIFIER ::= { fsModel 1086} -- FortiSwitch-108F +s448ep OBJECT IDENTIFIER ::= { fsModel 4486} -- FortiSwitch-448E-POE +s224en OBJECT IDENTIFIER ::= { fsModel 2243} -- FortiSwitch-224E +s108en OBJECT IDENTIFIER ::= { fsModel 1082} -- FortiSwitch-108E +sr24dn OBJECT IDENTIFIER ::= { fsModel 1243} -- FortiSwitchRugged-124D +s148ff OBJECT IDENTIFIER ::= { fsModel 1486} -- FortiSwitch-148F-FPOE +s148ep OBJECT IDENTIFIER ::= { fsModel 1248} -- FortiSwitch-148E-POE +s108dv OBJECT IDENTIFIER ::= { fsModel 1085} -- FortiSwitch-108D-VM +s124fn OBJECT IDENTIFIER ::= { fsModel 12410} -- FortiSwitch-124F +s524dn OBJECT IDENTIFIER ::= { fsModel 5242} -- FortiSwitch-524D +s124ep OBJECT IDENTIFIER ::= { fsModel 1245} -- FortiSwitch-124E-POE +s148fn OBJECT IDENTIFIER ::= { fsModel 1484} -- FortiSwitch-148F +s524df OBJECT IDENTIFIER ::= { fsModel 5241} -- FortiSwitch-524D-FPOE +s148fp OBJECT IDENTIFIER ::= { fsModel 1485} -- FortiSwitch-148F-POE +s124dp OBJECT IDENTIFIER ::= { fsModel 1242} -- FortiSwitch-124D-POE +s424dn OBJECT IDENTIFIER ::= { fsModel 4241} -- FortiSwitch-424D +s108fp OBJECT IDENTIFIER ::= { fsModel 1087} -- FortiSwitch-108F-POE +s148en OBJECT IDENTIFIER ::= { fsModel 1247} -- FortiSwitch-148E +s248dp OBJECT IDENTIFIER ::= { fsModel 2481} -- FortiSwitch-248D-POE +s424dp OBJECT IDENTIFIER ::= { fsModel 4242} -- FortiSwitch-424D-POE +fs3d32 OBJECT IDENTIFIER ::= { fsModel 30321} -- FortiSwitch-3032D +fs1d24 OBJECT IDENTIFIER ::= { fsModel 10241} -- FortiSwitch-1024D +s124dn OBJECT IDENTIFIER ::= { fsModel 1241} -- FortiSwitch-124D +s424ei OBJECT IDENTIFIER ::= { fsModel 42404} -- FortiSwitch-424E-Fiber +s248df OBJECT IDENTIFIER ::= { fsModel 2482} -- FortiSwitch-248D-FPOE +fs1e24 OBJECT IDENTIFIER ::= { fsModel 10242} -- FortiSwitch-1024E +s124en OBJECT IDENTIFIER ::= { fsModel 1244} -- FortiSwitch-124E +fs3e32 OBJECT IDENTIFIER ::= { fsModel 30322} -- FortiSwitch-3032E +s448dn OBJECT IDENTIFIER ::= { fsModel 4482} -- FortiSwitch-448D +s424ep OBJECT IDENTIFIER ::= { fsModel 42402} -- FortiSwitch-424E-POE +s108ef OBJECT IDENTIFIER ::= { fsModel 1084} -- FortiSwitch-108E-FPOE +s448dp OBJECT IDENTIFIER ::= { fsModel 4484} -- FortiSwitch-448D-POE +s224df OBJECT IDENTIFIER ::= { fsModel 2242} -- FortiSwitch-224D-FPOE +s248ep OBJECT IDENTIFIER ::= { fsModel 2485} -- FortiSwitch-248E-POE +s248ef OBJECT IDENTIFIER ::= { fsModel 2484} -- FortiSwitch-248E-FPOE +s548dn OBJECT IDENTIFIER ::= { fsModel 5482} -- FortiSwitch-548D +s426ef OBJECT IDENTIFIER ::= { fsModel 42405} -- FortiSwitch-M426E-FPOE +s448df OBJECT IDENTIFIER ::= { fsModel 4483} -- FortiSwitch-448D-FPOE +s124ef OBJECT IDENTIFIER ::= { fsModel 1246} -- FortiSwitch-124E-FPOE +s424ef OBJECT IDENTIFIER ::= { fsModel 42403} -- FortiSwitch-424E-FPOE +s548df OBJECT IDENTIFIER ::= { fsModel 5481} -- FortiSwitch-548D-FPOE +st1e24 OBJECT IDENTIFIER ::= { fsModel 10243} -- FortiSwitch-T1024E +s424en OBJECT IDENTIFIER ::= { fsModel 42401} -- FortiSwitch-424E +s108ep OBJECT IDENTIFIER ::= { fsModel 1083} -- FortiSwitch-108E-POE +s448en OBJECT IDENTIFIER ::= { fsModel 4485} -- FortiSwitch-448E +s108ff OBJECT IDENTIFIER ::= { fsModel 1088} -- FortiSwitch-108F-FPOE +sr12dp OBJECT IDENTIFIER ::= { fsModel 1121} -- FortiSwitchRugged-112D-POE +fs1e48 OBJECT IDENTIFIER ::= { fsModel 10482} -- FortiSwitch-1048E +s448ef OBJECT IDENTIFIER ::= { fsModel 4487} -- FortiSwitch-448E-FPOE +s224ep OBJECT IDENTIFIER ::= { fsModel 2244} -- FortiSwitch-224E-POE +s248dn OBJECT IDENTIFIER ::= { fsModel 2483} -- FortiSwitch-248D +s124ff OBJECT IDENTIFIER ::= { fsModel 1249} -- FortiSwitch-124F-FPOE +fs1d48 OBJECT IDENTIFIER ::= { fsModel 10481} -- FortiSwitch-1048D + +-- fsModel end + -- -- fortinet.fnFortiSwitchMib.fsMibConformance --