-
Notifications
You must be signed in to change notification settings - Fork 37
/
MyMessage.h
302 lines (271 loc) · 17.2 KB
/
MyMessage.h
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
/*
* The MySensors Arduino library handles the wireless radio link and protocol
* between your home built sensors/actuators and HA controller of choice.
* The sensors forms a self healing radio network with optional repeaters. Each
* repeater and gateway builds a routing tables in EEPROM which keeps track of the
* network topology allowing messages to be routed to nodes.
*
* Created by Henrik Ekblad <[email protected]>
* Copyright (C) 2013-2017 Sensnology AB
* Full contributor list: https://github.com/mysensors/Arduino/graphs/contributors
*
* Documentation: http://www.mysensors.org
* Support Forum: http://forum.mysensors.org
*
* This program is free software; you can redistribute it and/or
* modify it under the terms of the GNU General Public License
* version 2 as published by the Free Software Foundation.
*/
#ifndef MyMessage_h
#define MyMessage_h
#define PROTOCOL_VERSION (2u) //!< The version of the protocol
#define MAX_MESSAGE_LENGTH (32u) //!< The maximum size of a message (including header)
#define HEADER_SIZE (7u) //!< The size of the header
#define MAX_PAYLOAD (MAX_MESSAGE_LENGTH - HEADER_SIZE) //!< The maximum size of a payload depends on #MAX_MESSAGE_LENGTH and #HEADER_SIZE
/// @brief The command field (message-type) defines the overall properties of a message
typedef enum {
C_PRESENTATION = 0, //!< Sent by a node when they present attached sensors. This is usually done in presentation() at startup.
C_SET = 1, //!< This message is sent from or to a sensor when a sensor value should be updated.
C_REQ = 2, //!< Requests a variable value (usually from an actuator destined for controller).
C_INTERNAL = 3, //!< Internal MySensors messages (also include common messages provided/generated by the library).
C_STREAM = 4 //!< For firmware and other larger chunks of data that need to be divided into pieces.
} mysensor_command;
/// @brief Type of sensor (used when presenting sensors)
typedef enum {
S_DOOR = 0, //!< Door sensor, V_TRIPPED, V_ARMED
S_MOTION = 1, //!< Motion sensor, V_TRIPPED, V_ARMED
S_SMOKE = 2, //!< Smoke sensor, V_TRIPPED, V_ARMED
S_BINARY = 3, //!< Binary light or relay, V_STATUS, V_WATT
S_LIGHT = 3, //!< \deprecated Same as S_BINARY, **** DEPRECATED, DO NOT USE ****
S_DIMMER = 4, //!< Dimmable light or fan device, V_STATUS (on/off), V_PERCENTAGE (dimmer level 0-100), V_WATT
S_COVER = 5, //!< Blinds or window cover, V_UP, V_DOWN, V_STOP, V_PERCENTAGE (open/close to a percentage)
S_TEMP = 6, //!< Temperature sensor, V_TEMP
S_HUM = 7, //!< Humidity sensor, V_HUM
S_BARO = 8, //!< Barometer sensor, V_PRESSURE, V_FORECAST
S_WIND = 9, //!< Wind sensor, V_WIND, V_GUST
S_RAIN = 10, //!< Rain sensor, V_RAIN, V_RAINRATE
S_UV = 11, //!< Uv sensor, V_UV
S_WEIGHT = 12, //!< Personal scale sensor, V_WEIGHT, V_IMPEDANCE
S_POWER = 13, //!< Power meter, V_WATT, V_KWH, V_VAR, V_VA, V_POWER_FACTOR
S_HEATER = 14, //!< Header device, V_HVAC_SETPOINT_HEAT, V_HVAC_FLOW_STATE, V_TEMP
S_DISTANCE = 15, //!< Distance sensor, V_DISTANCE
S_LIGHT_LEVEL = 16, //!< Light level sensor, V_LIGHT_LEVEL (uncalibrated in percentage), V_LEVEL (light level in lux)
S_ARDUINO_NODE = 17, //!< Used (internally) for presenting a non-repeating Arduino node
S_ARDUINO_REPEATER_NODE = 18, //!< Used (internally) for presenting a repeating Arduino node
S_LOCK = 19, //!< Lock device, V_LOCK_STATUS
S_IR = 20, //!< IR device, V_IR_SEND, V_IR_RECEIVE
S_WATER = 21, //!< Water meter, V_FLOW, V_VOLUME
S_AIR_QUALITY = 22, //!< Air quality sensor, V_LEVEL
S_CUSTOM = 23, //!< Custom sensor
S_DUST = 24, //!< Dust sensor, V_LEVEL
S_SCENE_CONTROLLER = 25, //!< Scene controller device, V_SCENE_ON, V_SCENE_OFF.
S_RGB_LIGHT = 26, //!< RGB light. Send color component data using V_RGB. Also supports V_WATT
S_RGBW_LIGHT = 27, //!< RGB light with an additional White component. Send data using V_RGBW. Also supports V_WATT
S_COLOR_SENSOR = 28, //!< Color sensor, send color information using V_RGB
S_HVAC = 29, //!< Thermostat/HVAC device. V_HVAC_SETPOINT_HEAT, V_HVAC_SETPOINT_COLD, V_HVAC_FLOW_STATE, V_HVAC_FLOW_MODE, V_TEMP
S_MULTIMETER = 30, //!< Multimeter device, V_VOLTAGE, V_CURRENT, V_IMPEDANCE
S_SPRINKLER = 31, //!< Sprinkler, V_STATUS (turn on/off), V_TRIPPED (if fire detecting device)
S_WATER_LEAK = 32, //!< Water leak sensor, V_TRIPPED, V_ARMED
S_SOUND = 33, //!< Sound sensor, V_TRIPPED, V_ARMED, V_LEVEL (sound level in dB)
S_VIBRATION = 34, //!< Vibration sensor, V_TRIPPED, V_ARMED, V_LEVEL (vibration in Hz)
S_MOISTURE = 35, //!< Moisture sensor, V_TRIPPED, V_ARMED, V_LEVEL (water content or moisture in percentage?)
S_INFO = 36, //!< LCD text device / Simple information device on controller, V_TEXT
S_GAS = 37, //!< Gas meter, V_FLOW, V_VOLUME
S_GPS = 38, //!< GPS Sensor, V_POSITION
S_WATER_QUALITY = 39 //!< V_TEMP, V_PH, V_ORP, V_EC, V_STATUS
} mysensor_sensor;
/// @brief Type of sensor data (for set/req/ack messages)
typedef enum {
V_TEMP = 0, //!< S_TEMP. Temperature S_TEMP, S_HEATER, S_HVAC
V_HUM = 1, //!< S_HUM. Humidity
V_STATUS = 2, //!< S_BINARY, S_DIMMER, S_SPRINKLER, S_HVAC, S_HEATER. Used for setting/reporting binary (on/off) status. 1=on, 0=off
V_LIGHT = 2, //!< \deprecated Same as V_STATUS, **** DEPRECATED, DO NOT USE ****
V_PERCENTAGE = 3, //!< S_DIMMER. Used for sending a percentage value 0-100 (%).
V_DIMMER = 3, //!< \deprecated Same as V_PERCENTAGE, **** DEPRECATED, DO NOT USE ****
V_PRESSURE = 4, //!< S_BARO. Atmospheric Pressure
V_FORECAST = 5, //!< S_BARO. Whether forecast. string of "stable", "sunny", "cloudy", "unstable", "thunderstorm" or "unknown"
V_RAIN = 6, //!< S_RAIN. Amount of rain
V_RAINRATE = 7, //!< S_RAIN. Rate of rain
V_WIND = 8, //!< S_WIND. Wind speed
V_GUST = 9, //!< S_WIND. Gust
V_DIRECTION = 10, //!< S_WIND. Wind direction 0-360 (degrees)
V_UV = 11, //!< S_UV. UV light level
V_WEIGHT = 12, //!< S_WEIGHT. Weight(for scales etc)
V_DISTANCE = 13, //!< S_DISTANCE. Distance
V_IMPEDANCE = 14, //!< S_MULTIMETER, S_WEIGHT. Impedance value
V_ARMED = 15, //!< S_DOOR, S_MOTION, S_SMOKE, S_SPRINKLER. Armed status of a security sensor. 1 = Armed, 0 = Bypassed
V_TRIPPED = 16, //!< S_DOOR, S_MOTION, S_SMOKE, S_SPRINKLER, S_WATER_LEAK, S_SOUND, S_VIBRATION, S_MOISTURE. Tripped status of a security sensor. 1 = Tripped, 0
V_WATT = 17, //!< S_POWER, S_BINARY, S_DIMMER, S_RGB_LIGHT, S_RGBW_LIGHT. Watt value for power meters
V_KWH = 18, //!< S_POWER. Accumulated number of KWH for a power meter
V_SCENE_ON = 19, //!< S_SCENE_CONTROLLER. Turn on a scene
V_SCENE_OFF = 20, //!< S_SCENE_CONTROLLER. Turn of a scene
V_HVAC_FLOW_STATE = 21, //!< S_HEATER, S_HVAC. HVAC flow state ("Off", "HeatOn", "CoolOn", or "AutoChangeOver")
V_HEATER = 21, //!< \deprecated Same as V_HVAC_FLOW_STATE, **** DEPRECATED, DO NOT USE ****
V_HVAC_SPEED = 22, //!< S_HVAC, S_HEATER. HVAC/Heater fan speed ("Min", "Normal", "Max", "Auto")
V_LIGHT_LEVEL = 23, //!< S_LIGHT_LEVEL. Uncalibrated light level. 0-100%. Use V_LEVEL for light level in lux
V_VAR1 = 24, //!< VAR1
V_VAR2 = 25, //!< VAR2
V_VAR3 = 26, //!< VAR3
V_VAR4 = 27, //!< VAR4
V_VAR5 = 28, //!< VAR5
V_UP = 29, //!< S_COVER. Window covering. Up
V_DOWN = 30, //!< S_COVER. Window covering. Down
V_STOP = 31, //!< S_COVER. Window covering. Stop
V_IR_SEND = 32, //!< S_IR. Send out an IR-command
V_IR_RECEIVE = 33, //!< S_IR. This message contains a received IR-command
V_FLOW = 34, //!< S_WATER. Flow of water (in meter)
V_VOLUME = 35, //!< S_WATER. Water volume
V_LOCK_STATUS = 36, //!< S_LOCK. Set or get lock status. 1=Locked, 0=Unlocked
V_LEVEL = 37, //!< S_DUST, S_AIR_QUALITY, S_SOUND (dB), S_VIBRATION (hz), S_LIGHT_LEVEL (lux)
V_VOLTAGE = 38, //!< S_MULTIMETER
V_CURRENT = 39, //!< S_MULTIMETER
V_RGB = 40, //!< S_RGB_LIGHT, S_COLOR_SENSOR. Sent as ASCII hex: RRGGBB (RR=red, GG=green, BB=blue component)
V_RGBW = 41, //!< S_RGBW_LIGHT. Sent as ASCII hex: RRGGBBWW (WW=white component)
V_ID = 42, //!< Used for sending in sensors hardware ids (i.e. OneWire DS1820b).
V_UNIT_PREFIX = 43, //!< Allows sensors to send in a string representing the unit prefix to be displayed in GUI, not parsed by controller! E.g. cm, m, km, inch.
V_HVAC_SETPOINT_COOL = 44, //!< S_HVAC. HVAC cool setpoint (Integer between 0-100)
V_HVAC_SETPOINT_HEAT = 45, //!< S_HEATER, S_HVAC. HVAC/Heater setpoint (Integer between 0-100)
V_HVAC_FLOW_MODE = 46, //!< S_HVAC. Flow mode for HVAC ("Auto", "ContinuousOn", "PeriodicOn")
V_TEXT = 47, //!< S_INFO. Text message to display on LCD or controller device
V_CUSTOM = 48, //!< Custom messages used for controller/inter node specific commands, preferably using S_CUSTOM device type.
V_POSITION = 49, //!< GPS position and altitude. Payload: latitude;longitude;altitude(m). E.g. "55.722526;13.017972;18"
V_IR_RECORD = 50, //!< Record IR codes S_IR for playback
V_PH = 51, //!< S_WATER_QUALITY, water PH
V_ORP = 52, //!< S_WATER_QUALITY, water ORP : redox potential in mV
V_EC = 53, //!< S_WATER_QUALITY, water electric conductivity μS/cm (microSiemens/cm)
V_VAR = 54, //!< S_POWER, Reactive power: volt-ampere reactive (var)
V_VA = 55, //!< S_POWER, Apparent power: volt-ampere (VA)
V_POWER_FACTOR = 56, //!< S_POWER, Ratio of real power to apparent power: floating point value in the range [-1,..,1]
} mysensor_data;
/// @brief Type of internal messages (for internal messages)
typedef enum {
I_BATTERY_LEVEL = 0, //!< Battery level
I_TIME = 1, //!< Time (request/response)
I_VERSION = 2, //!< Version
I_ID_REQUEST = 3, //!< ID request
I_ID_RESPONSE = 4, //!< ID response
I_INCLUSION_MODE = 5, //!< Inclusion mode
I_CONFIG = 6, //!< Config (request/response)
I_FIND_PARENT_REQUEST = 7, //!< Find parent
I_FIND_PARENT_RESPONSE = 8, //!< Find parent response
I_LOG_MESSAGE = 9, //!< Log message
I_CHILDREN = 10, //!< Children
I_SKETCH_NAME = 11, //!< Sketch name
I_SKETCH_VERSION = 12, //!< Sketch version
I_REBOOT = 13, //!< Reboot request
I_GATEWAY_READY = 14, //!< Gateway ready
I_SIGNING_PRESENTATION = 15, //!< Provides signing related preferences (first byte is preference version)
I_NONCE_REQUEST = 16, //!< Request for a nonce
I_NONCE_RESPONSE = 17, //!< Payload is nonce data
I_HEARTBEAT_REQUEST = 18, //!< Heartbeat request
I_PRESENTATION = 19, //!< Presentation message
I_DISCOVER_REQUEST = 20, //!< Discover request
I_DISCOVER_RESPONSE = 21, //!< Discover response
I_HEARTBEAT_RESPONSE = 22, //!< Heartbeat response
I_LOCKED = 23, //!< Node is locked (reason in string-payload)
I_PING = 24, //!< Ping sent to node, payload incremental hop counter
I_PONG = 25, //!< In return to ping, sent back to sender, payload incremental hop counter
I_REGISTRATION_REQUEST = 26, //!< Register request to GW
I_REGISTRATION_RESPONSE = 27, //!< Register response from GW
I_DEBUG = 28, //!< Debug message
I_SIGNAL_REPORT_REQUEST = 29, //!< Device signal strength request
I_SIGNAL_REPORT_REVERSE = 30, //!< Internal
I_SIGNAL_REPORT_RESPONSE = 31, //!< Device signal strength response (RSSI)
I_PRE_SLEEP_NOTIFICATION = 32, //!< Message sent before node is going to sleep
I_POST_SLEEP_NOTIFICATION = 33 //!< Message sent after node woke up (if enabled)
} mysensor_internal;
/// @brief Type of data stream (for streamed message)
typedef enum {
ST_FIRMWARE_CONFIG_REQUEST = 0, //!< Request new FW, payload contains current FW details
ST_FIRMWARE_CONFIG_RESPONSE = 1, //!< New FW details to initiate OTA FW update
ST_FIRMWARE_REQUEST = 2, //!< Request FW block
ST_FIRMWARE_RESPONSE = 3, //!< Response FW block
ST_SOUND = 4, //!< Sound
ST_IMAGE = 5 //!< Image
} mysensor_stream;
/// @brief Type of payload
typedef enum {
P_STRING = 0, //!< Payload type is string
P_BYTE = 1, //!< Payload type is byte
P_INT16 = 2, //!< Payload type is INT16
P_UINT16 = 3, //!< Payload type is UINT16
P_LONG32 = 4, //!< Payload type is INT32
P_ULONG32 = 5, //!< Payload type is UINT32
P_CUSTOM = 6, //!< Payload type is binary
P_FLOAT32 = 7 //!< Payload type is float32
} mysensor_payload;
#ifndef BIT
#define BIT(n) ( 1<<(n) ) //!< Bit indexing macro
#endif
#define BIT_MASK(len) ( BIT(len)-1 ) //!< Create a bitmask of length 'len'
#define BF_MASK(start, len) ( BIT_MASK(len)<<(start) ) //!< Create a bitfield mask of length starting at bit 'start'
#define BF_PREP(x, start, len) ( ((x)&BIT_MASK(len)) << (start) ) //!< Prepare a bitmask for insertion or combining
#define BF_GET(y, start, len) ( ((y)>>(start)) & BIT_MASK(len) ) //!< Extract a bitfield of length 'len' starting at bit 'start' from 'y'
#define BF_SET(y, x, start, len) ( y= ((y) &~ BF_MASK(start, len)) | BF_PREP(x, start, len) ) //!< Insert a new bitfield value 'x' into 'y'
// Getters/setters for special bit fields in header
#define mSetVersion(_message,_version) BF_SET(_message.version_length, _version, 0, 2) //!< Set version field
#define mGetVersion(_message) ((uint8_t)BF_GET(_message.version_length, 0, 2)) //!< Get version field
#define mSetSigned(_message,_signed) BF_SET(_message.version_length, _signed, 2, 1) //!< Set signed field
#define mGetSigned(_message) ((bool)BF_GET(_message.version_length, 2, 1)) //!< Get versignedsion field
#define mSetLength(_message,_length) BF_SET(_message.version_length, _length, 3, 5) //!< Set length field
#define mGetLength(_message) ((uint8_t)BF_GET(_message.version_length, 3, 5)) //!< Get length field
#define mSetCommand(_message,_command) BF_SET(_message.command_ack_payload, _command, 0, 3) //!< Set command field
#define mGetCommand(_message) ((uint8_t)BF_GET(_message.command_ack_payload, 0, 3)) //!< Get command field
#define mSetRequestAck(_message,_rack) BF_SET(_message.command_ack_payload, _rack, 3, 1) //!< Set ack-request field
#define mGetRequestAck(_message) ((bool)BF_GET(_message.command_ack_payload, 3, 1)) //!< Get ack-request field
#define mSetAck(_message,_ackMsg) BF_SET(_message.command_ack_payload, _ackMsg, 4, 1) //!< Set ack field
#define mGetAck(_message) ((bool)BF_GET(_message.command_ack_payload, 4, 1)) //!< Get ack field
#define mSetPayloadType(_message, _pt) BF_SET(_message.command_ack_payload, _pt, 5, 3) //!< Set payload type field
#define mGetPayloadType(_message) ((uint8_t)BF_GET(_message.command_ack_payload, 5, 3)) //!< Get payload type field
// internal access for special fields
#define miGetCommand() ((uint8_t)BF_GET(command_ack_payload, 0, 3)) //!< Internal getter for command field
#define miSetLength(_length) BF_SET(version_length, _length, 3, 5) //!< Internal setter for length field
#define miGetLength() ((uint8_t)BF_GET(version_length, 3, 5)) //!< Internal getter for length field
#define miSetVersion(_version) BF_SET(version_length, _version, 0, 2) //!< Internal setter for version field
#define miGetVersion() ((uint8_t)BF_GET(version_length, 0, 2)) //!< Internal getter for version field
#define miSetRequestAck(_rack) BF_SET(command_ack_payload, _rack, 3, 1) //!< Internal setter for ack-request field
#define miGetRequestAck() ((bool)BF_GET(command_ack_payload, 3, 1)) //!< Internal getter for ack-request field
#define miSetAck(_ack) BF_SET(command_ack_payload, _ack, 4, 1) //!< Internal setter for ack field
#define miGetAck() ((bool)BF_GET(command_ack_payload, 4, 1)) //!< Internal getter for ack field
#define miSetPayloadType(_pt) BF_SET(command_ack_payload, _pt, 5, 3) //!< Internal setter for payload type field
#define miGetPayloadType() (uint8_t)BF_GET(command_ack_payload, 5, 3) //!< Internal getter for payload type field
#pragma GCC diagnostic push
#pragma GCC diagnostic ignored "-Wpedantic"
typedef union {
struct {
uint8_t last; // 8 bit - Id of last node this message passed
uint8_t sender; // 8 bit - Id of sender node (origin)
uint8_t destination; // 8 bit - Id of destination node
uint8_t version_length; // 2 bit - Protocol version
// 1 bit - Signed flag
// 5 bit - Length of payload
uint8_t command_ack_payload; // 3 bit - Command type
// 1 bit - Request an ack - Indicator that receiver should send an ack back.
// 1 bit - Is ack messsage - Indicator that this is the actual ack message.
// 3 bit - Payload data type
uint8_t type; // 8 bit - Type varies depending on command
uint8_t sensor; // 8 bit - Id of sensor that this message concerns.
// Each message can transfer a payload. We add one extra byte for string
// terminator \0 to be "printable" this is not transferred OTA
// This union is used to simplify the construction of the binary data types transferred.
union {
uint8_t bValue;
uint16_t uiValue;
int16_t iValue;
uint32_t ulValue;
int32_t lValue;
struct { // Float messages
float fValue;
uint8_t fPrecision; // Number of decimals when serializing
} msg_float;
struct { // Presentation messages
uint8_t version; // Library version
uint8_t sensorType; // Sensor type hint for controller, see table above
} msg_presentation;
char data[MAX_PAYLOAD + 1];
} __attribute__((packed)) payload;
};
uint8_t array[HEADER_SIZE + MAX_PAYLOAD + 1];
} __attribute__((packed)) MyMessage;
#pragma GCC diagnostic pop
#endif