Are you sure about the image orientations of both images?
On Thu, Sep 1, 2022 at 5:02 PM Dilek Ozkan ***@***.***> wrote:
Hello,
I want to convert the 3d 1*1*1 flair image of the same patient to 3d 1*1*5
flair. And I want it to be in the transversal plane. I opened applyxfm in
the user interface in fsl.
I put the flair image of the patient with the voxel sizes I wanted as the
reference volume. It only takes the patient's voxel dimensions, not the
image content, am i right? If the image will register, it will be wrong..
And I clicked the identity matrix button as transformation matrix question.
Is there anything wrong with all this? Please let me know.
By the way, i ran this command and it didnt work.
flirt -in /ms/flairhigh.nii -ref /ms/flairhigh.nii -applyxfm -out /ms/out
The image came in sagittal, but the transverse plane I put in was (user
interface option)
Thanks in advance!
—
Reply to this email directly, view it on GitHub
<#33>, or unsubscribe
<https://github.com/notifications/unsubscribe-auth/AAIGPLSXRIA7ROBZHXS7OETV4EKWZANCNFSM6AAAAAAQCW6CAU>
.
You are receiving this because you are subscribed to this thread.Message
ID: ***@***.***>
--
Best,
John
|
3d 111 images has not specific direction, i can see the different orientation. And the other reference was a different patient's transvers scan as the voxel size 1 1 5 |
the output of the command: flirt -in /ms/flairhigh.nii -ref /ms/flairtransvers.nii -applyxfm -out /ms/out It is my input it is my reference (this is the 2d flair of another patient) |
Hello,
I want to convert the 3d 111 flair image of the same patient to 3d 115 flair. And I want it to be in the transversal plane. I opened applyxfm in the user interface in fsl.
I put the flair image of the patient with the voxel sizes I wanted as the reference volume. It only takes the patient's voxel dimensions, not the image content, am i right? If the image will register, it will be wrong..
And I clicked the identity matrix button as transformation matrix question.
Is there anything wrong with all this? Please let me know.
By the way, i ran this command and it didnt work.
flirt -in /ms/flairhigh.nii -ref /ms/flairhigh.nii -applyxfm -out /ms/out
The image came in sagittal, but the transverse plane I put in was (user interface option)
Thanks in advance!
The text was updated successfully, but these errors were encountered: