This directory contains integration tests that test syscoind and its utilities in their entirety. It does not contain unit tests, which can be found in /src/test, /src/wallet/test, etc.
This directory contains the following sets of tests:
- functional which test the functionality of syscoind and syscoin-qt by interacting with them through the RPC and P2P interfaces.
- util which tests the syscoin utilities, currently only syscoin-tx.
- lint which perform various static analysis checks.
The util tests are run as part of make check
target. The functional
tests and lint scripts are run by the travis continuous build process whenever a pull
request is opened. All sets of tests can also be run locally.
Before tests can be run locally, Syscoin Core must be built. See the building instructions for help.
The ZMQ functional test requires a python ZMQ library. To install it:
- on Unix, run
sudo apt-get install python3-zmq
- on mac OS, run
pip3 install pyzmq
Individual tests can be run by directly calling the test script, e.g.:
test/functional/feature_rbf.py
or can be run through the test_runner harness, eg:
test/functional/test_runner.py feature_rbf.py
You can run any combination (incl. duplicates) of tests by calling:
test/functional/test_runner.py <testname1> <testname2> <testname3> ...
Run the regression test suite with:
test/functional/test_runner.py
Run all possible tests with
test/functional/test_runner.py --extended
By default, up to 4 tests will be run in parallel by test_runner. To specify
how many jobs to run, append --jobs=n
The individual tests and the test_runner harness have many command-line
options. Run test_runner.py -h
to see them all.
The P2P and RPC ports used by the syscoind nodes-under-test are chosen to make conflicts with other processes unlikely. However, if there is another syscoind process running on the system (perhaps from a previous test which hasn't successfully killed all its syscoind nodes), then there may be a port conflict which will cause the test to fail. It is recommended that you run the tests on a system where no other syscoind processes are running.
On linux, the test_framework will warn if there is another syscoind process running when the tests are started.
If there are zombie syscoind processes after test failure, you can kill them by running the following commands. Note that these commands will kill all syscoind processes running on the system, so should not be used if any non-test syscoind processes are being run.
killall syscoind
or
pkill -9 syscoind
A pre-mined blockchain with 200 blocks is generated the first time a functional test is run and is stored in test/cache. This speeds up test startup times since new blockchains don't need to be generated for each test. However, the cache may get into a bad state, in which case tests will fail. If this happens, remove the cache directory (and make sure syscoind processes are stopped as above):
rm -rf cache
killall syscoind
The tests contain logging at different levels (debug, info, warning, etc). By default:
- when run through the test_runner harness, all logs are written to
test_framework.log
and no logs are output to the console. - when run directly, all logs are written to
test_framework.log
and INFO level and above are output to the console. - when run on Travis, no logs are output to the console. However, if a test
fails, the
test_framework.log
and syscoinddebug.log
s will all be dumped to the console to help troubleshooting.
To change the level of logs output to the console, use the -l
command line
argument.
test_framework.log
and syscoind debug.log
s can be combined into a single
aggregate log by running the combine_logs.py
script. The output can be plain
text, colorized text or html. For example:
combine_logs.py -c <test data directory> | less -r
will pipe the colorized logs from the test into less.
Use --tracerpc
to trace out all the RPC calls and responses to the console. For
some tests (eg any that use submitblock
to submit a full block over RPC),
this can result in a lot of screen output.
By default, the test data directory will be deleted after a successful run.
Use --nocleanup
to leave the test data directory intact. The test data
directory is never deleted after a failed test.
A python debugger can be attached to tests at any point. Just add the line:
import pdb; pdb.set_trace()
anywhere in the test. You will then be able to inspect variables, as well as call methods that interact with the syscoind nodes-under-test.
If further introspection of the syscoind instances themselves becomes
necessary, this can be accomplished by first setting a pdb breakpoint
at an appropriate location, running the test to that point, then using
gdb
to attach to the process and debug.
For instance, to attach to self.node[1]
during a run:
2017-06-27 14:13:56.686000 TestFramework (INFO): Initializing test directory /tmp/user/1000/testo9vsdjo3
use the directory path to get the pid from the pid file:
cat /tmp/user/1000/testo9vsdjo3/node1/regtest/syscoind.pid
gdb /home/example/syscoind <pid>
Note: gdb attach step may require ptrace_scope to be modified, or sudo
preceding the gdb
.
See this link for considerations: https://www.kernel.org/doc/Documentation/security/Yama.txt
An easy way to profile node performance during functional tests is provided
for Linux platforms using perf
.
Perf will sample the running node and will generate profile data in the node's
datadir. The profile data can then be presented using perf report
or a graphical
tool like hotspot.
To generate a profile during test suite runs, use the --perf
flag.
To see render the output to text, run
perf report -i /path/to/datadir/send-big-msgs.perf.data.xxxx --stdio | c++filt | less
For ways to generate more granular profiles, see the README in test/functional.
Util tests can be run locally by running test/util/syscoin-util-test.py
.
Use the -v
option for verbose output.
The lint tests require codespell and flake8. To install: pip3 install codespell flake8
.
Individual tests can be run by directly calling the test script, e.g.:
test/lint/lint-filenames.sh
You can run all the shell-based lint tests by running:
test/lint/lint-all.sh
You are encouraged to write functional tests for new or existing features. Further information about the functional test framework and individual tests is found in test/functional.