adjust color and brightness has no effect in Windows Fax and Scan (Canon Lide 110) #29

Open
alienshit opened this issue Apr 16, 2016 · 2 comments
Assignees
Labels

Comments

@alienshit
Copy link

alienshit commented Apr 16, 2016

I have testet wiasane in windows7 64 bit Professional.
The installation was quick and simple.
My scanner is connected to a DebianSane Server.
All features of NAPS2 are working fine with my Canon Lide 110 scanner.
Microsoft Fax and Scan works too, but changing of color or brightness has no effect.
Is ist possibile to fix it?
Do other scanner models support this funktions?
regards

@mback2k
Copy link
Owner

mback2k commented Sep 3, 2016

Please provide the output of winsane-dbg.exe <saned-hostname>. This way I can identify the relevant options needed to support color and brightness for your scanner.

@mback2k mback2k self-assigned this Oct 28, 2016
@mback2k mback2k added the bug label Oct 28, 2016
@schabau
Copy link

schabau commented Dec 25, 2017

Hello and have a nice Christmas

I was very happy when I found wiasane today.
But I have a similar problem here with an HP ScanJet G3110.
The color setting and also the resolution can be adjusted. But the brightness and the contrast is not.
In the output of winsane-dbg.exe, it seems to me that the HPG3110 does not support brightness and contrast but only the respective color gamma values. Or am I wrong?
With SaneTwain, the adjustment is made with the color gamma values.

Do I have a chance to integrate the gamma correction into wiasane?

The output of winsane-dbg.exe is here.

c:\Program Files\SANE WIA Driver>winsane-dbg.exe 192.168.0.100
------------------------------------------------------------
Name:   hp3900:libusb:001:002
Vendor: Hewlett-Packard
Model:  Scanjet G3110
Type:   flatbed scanner
------------------------------------------------------------
Name:
Title:          Number of options
Description:    Read-only option that specifies how many options a specific devices supports.
Value:          36
Unit:           None
------------------------------------------------------------
Name:           geometry
Title:          Geometry
Description:    Scan area and media size options
Value:          <FAIL>
Unit:           None
------------------------------------------------------------
Name:           tl-x
Title:          Top-left x
Description:    Top-left x position of scan area.
Value:          0
Unit:           Millimeter
Min:            0
Max:            220
Quant:          1
------------------------------------------------------------
Name:           tl-y
Title:          Top-left y
Description:    Top-left y position of scan area.
Value:          0
Unit:           Millimeter
Min:            0
Max:            300
Quant:          1
------------------------------------------------------------
Name:           br-x
Title:          Bottom-right x
Description:    Bottom-right x position of scan area.
Value:          220
Unit:           Millimeter
Min:            0
Max:            220
Quant:          1
------------------------------------------------------------
Name:           br-y
Title:          Bottom-right y
Description:    Bottom-right y position of scan area.
Value:          300
Unit:           Millimeter
Min:            0
Max:            300
Quant:          1
------------------------------------------------------------
Name:           resolution
Title:          Scan resolution
Description:    Sets the resolution of the scanned image.
Value:          50
Unit:           DPI
Word:           50
Word:           75
Word:           100
Word:           150
Word:           200
Word:           300
Word:           600
Word:           1200
Word:           2400
Word:           4800
Resolution:     300
------------------------------------------------------------
Name:           red-gamma-table
Title:          Red intensity
Description:    Gamma-correction table for the red band.
Value:          0
Unit:           None
Min:            0
Max:            65535
Quant:          0
------------------------------------------------------------
Name:           green-gamma-table
Title:          Green intensity
Description:    Gamma-correction table for the green band.
Value:          0
Unit:           None
Min:            0
Max:            65535
Quant:          0
------------------------------------------------------------
Name:           blue-gamma-table
Title:          Blue intensity
Description:    Gamma-correction table for the blue band.
Value:          0
Unit:           None
Min:            0
Max:            65535
Quant:          0
------------------------------------------------------------
Name:           source
Title:          Scan source
Description:    Selects the scan source (such as a document-feeder).
Value:          Flatbed
Unit:           None
String:         Flatbed
String:         Slide
String:         Negative
------------------------------------------------------------
Name:           mode
Title:          Scan mode
Description:    Selects the scan mode (e.g., lineart, monochrome, or color).
Value:          Color
Unit:           None
String:         Color
String:         Gray
String:         Lineart
Mode:           Color
------------------------------------------------------------
Name:           depth
Title:          Bit depth
Description:    Number of bits per sample, typical values are 1 for "line-art" and 8 for multibit scans.
Value:          8
Unit:           Bit
Word:           8
Word:           16
------------------------------------------------------------
Name:           threshold
Title:          Threshold
Description:    Select minimum-brightness to get a white point
Value:          <FAIL>
Unit:           None
Min:            0
Max:            255
Quant:          0
------------------------------------------------------------
Name:           grp_debug
Title:          Debugging Options
Description:
Value:          <FAIL>
Unit:           None
------------------------------------------------------------
Name:           opt_model
Title:          Scanner model
Description:    Allows one to test device behaviour with other supported models
Value:          HP3800
Unit:           None
String:         HP3800
String:         HP3970
String:         HP4070
String:         HP4370
String:         UA4900
String:         HPG3010
String:         BQ5550
String:         HPG2710
String:         HPG3110
------------------------------------------------------------
Name:           opt_negative
Title:          Negative
Description:    Image colours will be inverted
Value:          0
Unit:           None
------------------------------------------------------------
Name:           opt_nogamma
Title:          Disable gamma correction
Description:    Gamma correction will be disabled
Value:          0
Unit:           None
------------------------------------------------------------
Name:           opt_nowshading
Title:          Disable white shading correction
Description:    White shading correction will be disabled
Value:          0
Unit:           None
------------------------------------------------------------
Name:           opt_realdepth
Title:          Force real depth
Description:    If gamma is enabled, scans are always made in 16 bits depth to improve image quality and then converted to the selected depth. This option avoids depth emulation.
Value:          0
Unit:           None
------------------------------------------------------------
Name:           opt_emulategray
Title:          Emulate Grayscale
Description:    If enabled, image will be scanned in color mode and then converted to grayscale by software. This may improve image quality in some circumstances.
Value:          0
Unit:           None
------------------------------------------------------------
Name:           opt_nowarmup
Title:          Skip warmup process
Description:    Warmup process will be disabled
Value:          0
Unit:           None
------------------------------------------------------------
Name:           opt_dbgimages
Title:          Save debugging images
Description:    If enabled, some images involved in scanner processing are saved to analyze them.
Value:          0
Unit:           None
------------------------------------------------------------
Name:           opt_reset
Title:          Reset chipset
Description:    Resets chipset data
Value:          <FAIL>
Unit:           None
------------------------------------------------------------
Name:           grp_info
Title:          Information
Description:
Value:          <FAIL>
Unit:           None
------------------------------------------------------------
Name:           opt_chipname
Title:          Chipset name
Description:    Shows chipset name used in device.
Value:          Unknown
Unit:           None
------------------------------------------------------------
Name:           opt_chipid
Title:          Chipset ID
Description:    Shows the chipset ID
Value:          -1
Unit:           None
------------------------------------------------------------
Name:           opt_scancount
Title:          Scan counter
Description:    Shows the number of scans made by scanner
Value:          -1
Unit:           None
------------------------------------------------------------
Name:           opt_infoupdate
Title:          Update information
Description:    Updates information about device
Value:          <FAIL>
Unit:           None
------------------------------------------------------------
Name:           sensors
Title:          Sensors
Description:    Scanner sensors and buttons
Value:          <FAIL>
Unit:           None
------------------------------------------------------------
Name:           button 0
Title:          Scanner button 0
Description:    This option reflects a front panel scanner button
Value:          0
Unit:           None
------------------------------------------------------------
Name:           button 1
Title:          Scanner button 1
Description:    This option reflects a front panel scanner button
Value:          0
Unit:           None
------------------------------------------------------------
Name:           button 2
Title:          Scanner button 2
Description:    This option reflects a front panel scanner button
Value:          0
Unit:           None
------------------------------------------------------------
Name:           button 3
Title:          Scanner button 3
Description:    This option reflects a front panel scanner button
Value:          0
Unit:           None
------------------------------------------------------------
Name:           button 4
Title:          Scanner button 4
Description:    This option reflects a front panel scanner button
Value:          <FAIL>
Unit:           None
------------------------------------------------------------
Name:           button 5
Title:          Scanner button 5
Description:    This option reflects a front panel scanner button
Value:          <FAIL>
Unit:           None
------------------------------------------------------------
Format:         1
Last Frame:     1
Bytes per Line: 7794
Pixel per Line: 2598
Lines:          3543
Depth:          8
Scan? (y/n)