Notifications
You must be signed in to change notification settings - Fork 1
/
wxt_test.py
256 lines (218 loc) · 8.58 KB
/
wxt_test.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
# -*- coding: utf-8 -*-
"""
Created on Sat Mar 25 20:06:35 2017
@author: lauri.kangas
"""
import serial
import serial.tools.list_ports as list_ports
import time
import logging
from pprint import pprint
import json
class WXT520:
bauds = [9600]
messages = {'r1': 'Wind',
'r2': 'PTU',
'r3': 'Rain',
'r5': 'Status'}
@staticmethod
def find_wxt():
for port in list_ports.comports():
for baud in WXT520.bauds:
with serial.Serial(port[0], baud, timeout=1) as ser:
time.sleep(.1)
ser.flushInput()
ser.write(b'?\r\n')
response = ser.readline()
if response:
address = response[:1]
if address.isalnum():
ser.flushInput()
ser.write(address+b'XU\r\n')
settings_response = ser.readline()
if b'WXT520' in settings_response:
return port[0], address.decode()
else:
logging.debug(settings_response)
return None
@staticmethod
def crc16(msg):
c = 0
for a in msg:
c ^= a
for _ in range(8):
if c & 1:
c >>= 1
c ^= 0xA001
else:
c >>= 1
bytes_ = [0x40 | (c >> 12), 0x40 | ((c >> 6) & 0x3f), 0x40 | (c & 0x3f)]
return "".join(map(chr, bytes_)).encode()
@staticmethod
def check_crc(message):
message = message.strip()
return WXT520.crc16(message[:-3]) == message[-3:]
@staticmethod
def message_to_dict(message):
message = message.strip()[:-3].decode('ascii')
pieces = message.split(',')
d = dict()
message_code = pieces[0][1:]
try:
d['Type'] = WXT520.messages[message_code]
except KeyError:
return None
wxt_data = dict()
for piece in pieces[1:]:
if '=' in piece:
label, value = piece.split('=')
wxt_data[label] = value
formatted_data = dict()
def unit_value_pair(label):
key = label
value = wxt_data[label]
try:
return [float(value[:-1]), parse_unit((key, value))]
except ValueError:
raise ValueError("could not convert {}: '{}' to float"
.format(key, value[:-1]))
if d['Type'] == 'Wind':
speed = dict()
direction = dict()
speed['average'] = unit_value_pair('Sm')
speed['limits'] = [unit_value_pair('Sn'),
unit_value_pair('Sx')]
direction['average'] = unit_value_pair('Dm')
direction['limits'] = [unit_value_pair('Dn'),
unit_value_pair('Dx')]
formatted_data['Speed'] = speed
formatted_data['Direction'] = direction
if d['Type'] == 'PTU':
temperature_ambient = unit_value_pair('Ta')
temperature_internal = unit_value_pair('Tp')
humidity = unit_value_pair('Ua')
pressure = unit_value_pair('Pa')
formatted_data['Temperature'] = {
'Ambient': temperature_ambient,
'Internal': temperature_internal}
formatted_data['Humidity'] = humidity
formatted_data['Pressure'] = pressure
if d['Type'] == 'Rain':
rain = dict()
hail = dict()
rain['Intensity'] = unit_value_pair('Ri')
rain['Peak'] = unit_value_pair('Rp')
rain['Accumulation'] = unit_value_pair('Rc')
rain['Duration'] = unit_value_pair('Rd')
hail['Intensity'] = unit_value_pair('Hi')
hail['Peak'] = unit_value_pair('Hp')
hail['Accumulation'] = unit_value_pair('Hc')
hail['Duration'] = unit_value_pair('Hd')
formatted_data['Rain'] = rain
formatted_data['Hail'] = hail
if d['Type'] == 'Status':
status = dict()
voltages = dict()
voltages['Supply'] = unit_value_pair('Vs')
voltages['Reference'] = unit_value_pair('Vr')
heating_voltage, heating_status = unit_value_pair('Vh')
voltages['Heating'] = [heating_voltage, 'V']
status['Voltages'] = voltages
status['Heating'] = {'Temperature': unit_value_pair('Th'),
'Status': heating_status}
formatted_data = status
d['Data'] = formatted_data
return d
def __enter__(self):
return self
def __exit__(self, exc_type, exc_value, traceback):
self.ser.close()
pass
def __init__(self, port, address, baudrate=9600,timeout=1):
self.ser = serial.Serial(port, baudrate, timeout=timeout)
self.address = address
time.sleep(.1)
self.ser.flushInput()
self.ser.write(b'0XU,M=a\r\n')
response = self.ser.readline()
if not b',M=a' in response:
logging.error('No answer to ASCII automatic mode setting!')
self.ser.close()
raise ValueError('No answer to ASCII automatic mode setting!')
def readline(self):
line = self.ser.readline()
if not line:
return None
if not WXT520.check_crc(line):
return None
return line
def parse_unit(label_value):
temperature_units = {'C': 'C', 'F': 'F'}
speed_units = {'M': 'm/s', 'K': 'km/h', 'S': 'mph', 'N': 'kn'}
direction_units = {'D': 'deg'}
pressure_units = {'H': 'hPa', 'P': 'Pa', 'B': 'bar', 'M': 'mmHg', 'I': 'inHg'}
humidity_units = {'P': '%'}
rain_accumulation_units = {'M': 'mm', 'I': 'in'}
duration_units = {'S': 's', 's': 's'} # error in doc!
rain_intensity_units = {'M': 'mm/h', 'I': 'in/h'}
hail_accumulation_units = {'M': 'hits/cm2', 'I': 'hits/in2', 'H': 'hits'}
hail_intensity_units = {'M': 'hits/cm2h', 'I': 'hits/in2h', 'H': 'hits/h'}
voltage_units = {'V': 'V'}
heating_status = {'N': '0% hi-',
'V': '50% mid-hi',
'W': '100% lo-mid',
'F': '50% -lo'}
label, value = label_value
unit_chr = value[-1]
unit = ''
try:
if label == 'Id': # prevent this to reach the duration block
return None
elif label[0] == 'T':
unit = temperature_units[unit_chr]
elif label[0] == 'S':
unit = speed_units[unit_chr]
elif label[0] == 'D':
unit = direction_units[unit_chr]
elif label == 'Pa':
unit = pressure_units[unit_chr]
elif label == 'Ua':
unit = humidity_units[unit_chr]
elif label[-1] == 'd':
unit = duration_units[unit_chr]
elif label == 'Ri' or label == 'Rp':
unit = rain_intensity_units[unit_chr]
elif label == 'Rc':
unit = rain_accumulation_units[unit_chr]
elif label == 'Hi' or label == 'Hp':
unit = hail_intensity_units[unit_chr]
elif label == 'Hc':
unit = hail_accumulation_units[unit_chr]
elif label == 'Vh':
unit = heating_status[unit_chr]
elif label[0] == 'V':
unit = voltage_units[unit_chr]
except KeyError:
if unit_chr == '#':
unit = 'invalid'
else:
raise ValueError('Cannot parse unit character {}'.format(unit_chr))
return unit
root = logging.getLogger()
if root.handlers:
for handler in root.handlers:
root.removeHandler(handler)
logging.basicConfig(level=logging.DEBUG)#, format='%(asctime)s %(levelname)s %(message)s')
print(WXT520.find_wxt())
time.sleep(1)
with WXT520('COM5', address='0', timeout=10) as w:
t = time.time()
while time.time()-t < 600:
line = w.readline()
if line:
d = WXT520.message_to_dict(line)
if d['Type'] == 'PTU':
def valueprint(pair):
return "{} {}".format(*pair)
print(valueprint(d['Data']['Temperature']['Ambient']),
'--', valueprint(d['Data']['Humidity']))