# This calibration is for the eTape currently deployed at 053. It is fitted with
# a voltage divider rather than a 0-5 V output converter. This is probably the
# better option as the voltage divider is more robust than the output converter.
# Speaking with Chris Milone he said there is no chip in the voltage divider,
# which means a wiring error will not destroy the eTape. To make this work with
# a CS logger use the 5V out power supply and the following calibration curve.
library(dplyr)
library(readr)
# VDiff Range:
values <-
read_csv("water_level_cm, vdiff_mV
1, 2498.5
2, 2498.5
3, 2499.2
4, 2539.1
5, 2558.0
8, 2614.8
10, 2668.9
15, 2781.2
25, 3051.7
35, 3357.5
50, 3931.0
59, 4409.9
61.8, 4562.7")
# The eTape won't respond at less than 1-inch water level, so here I set 2.54 cm
# to the same value as 1 and 2.
# values <-
# values %>%
# add_row(water_level_cm = 2.54,
# vdiff_mV = 2498.5,
# .after = 2)
# The entire curve is non-linear, and rather than fit a non-linear curve I fit a
# linear curve to the lower range of values. After initial testing r^2 was best
# when doing 3-25 as a range of water levels. But mse was much lower over 3-15
# range. The entire curve is non-linear.
expected_range <-
values %>%
filter(water_level_cm >= 3,
water_level_cm <= 15)
mod <-
lm(water_level_cm ~ vdiff_mV,
data = expected_range)
coef(mod)
# Vout = (vin * r2) / (r1 + r2)