With the REST API you can control the outputs as well as request the current state of the charge controller and the outputs.

Control outputs Load, Out1, Out2 and Out3

For controlling the outputs you have to send a POST, PUT or PATCH request to the endpoint /api/control containing a JSON body with the desired state. To turn the load output on the body needs to contain {"load":true}, to turn it off {"load":false}. For the three control outputs this is done in a similar manner. To turn on Out1 the body needs to contain {"out1":true}, to turn it off {"out1":false}. The same applies to Out2 (on: {"out2":true}, off: {"out2":false}) and Out3 (on: {"out3":true}, off: {"out3":false}) You are also able to control multiple outputs at the same time. For example the following body will turn on the Load and Out2 and at the same time turn off Out1 and Out3: {"load":true,"out2":true,"out3":false,"out1":false}.

You can also try this using curl for that replace the placeholer IP with the ip address of RNGBridge:

curl -X POST -H "Content-Type: application/json" -d '{"load":true}' IP/api/control
curl -X POST -H "Content-Type: application/json" -d '{"load":true,"out2":true,"out3":false,"out1":false}' IP/api/control

Note if you have setup automatic control of the load output, out1, out2 or out3 you might be able to change the state of the output using the REST interface, but it will probably be overwritten by the automatic control in the next update cycle. So make sure that automatic control is disabled if you want to use this feature.

Requesting controller state

For getting the state of the charge controller you have to send a GET request to the endpoint /api/state. RNGBridge will then return a current state JSON object similar to the one returned with MQTT. If wanted the MQTT obect could be extended to also have these values included.

Data Structure

{
    "mqttsta": "Connected",
    "otasta": "2.7.0",
    "pvosta": "Disabled",
    "b": {
        "ch": 79,
        "vo": 12.11761,
        "cu": 8.252449,
        "te": 18,
        "ge": 100,
        "co": 51
    },
    "l": {
        "vo": 12.11761,
        "cu": 0
    },
    "p": {
        "vo": 13.9,
        "cu": 7.194245
    },
    "c": {
        "st": 1,
        "er": 0,
        "te": 19
    },
    "o": {
        "l": false,
        "o1": false,
        "o2": false,
        "o3": false
    },
    "up": 80,
    "he": 38008,
    "rssi": -76
}

Data values

Object/Variable Type Value Description
b Object - JSON object containing battery data
ch Number 0 - 100 Battery charge in %
vo Float 0.0 - XX.X Battery voltage in Volts
cu Float 0.0 - XX.X Battery current in Ampere
te Float 0.0 - XX.X Battery temperature in degrees C
ge Number 0 - X Daily energy generation in Watthours
co Number 0 - X Daily energy consumption in Watthours
l Object - JSON object containing load data
vo Float 0.0 - XX.X Load voltage in Volts
cu Float 0.0 - XX.X Load current in Ampere
p Object - JSON object containing solar panel data
vo Float 0.0 - XX.X Solar panel voltage in Volts
cu Float 0.0 - XX.X Solar panel current in Ampere
c Object - JSON object containing controller state data
st Number 0 - 6 Charge controller state, mode of operation
er Number 0 - 33488896 Charge controller error state
te Float 0.0 - XX.X Charge controller temperature in degrees C
o Object - JSON object containing output states
l Bool true/false Charge controller load output enabled(true) or disabled(false)
o1 Bool true/false RNGBridge Out1 enabled(true) or disabled(false)
o2 Bool true/false RNGBridge Out2 enabled(true) or disabled(false)
o3 Bool true/false RNGBridge Out3 enabled(true) or disabled(false)
mqttsta Bool String Current human readable state of the MQTT module of RNGBridge
otasta Bool String Latest available version number of RNGBridge, only present if a software update is available
pvosta Bool String Current human readable state of the PVOutput module of RNGBridge
up Bool Number Uptime in seconds
he Bool Number Current heap usage in bytes
rssi Number -150 - 0 WiFi signal strength aka rssi in dBm

state values

  • 0: charging deactivated
  • 1: charging activated
  • 2: mppt charging mode
  • 3: equalizing charging mode
  • 4: boost charging mode
  • 5: floating charging mode
  • 6: current limiting (overpower)

errorState values

  • B31: Reserved
  • B30: Charge MOS short circuit
  • B29: Anti-reverse MOS short circuit
  • B28: Solar panel reversly connected
  • B27: Solar panel working point over-voltage
  • B26: Solar panel counter current
  • B25: Photovoltaic input side over voltage
  • B24: Photovoltaic input side short circuit
  • B23: Photovoltaic input overpower
  • B22: Ambient temperature too high
  • B21: Controller temperature too high
  • B20: Load overpower or load over-current
  • B19: Load short circuit
  • B18: Battery under-voltage warning
  • B17: Battery over-voltage
  • B16: battery over-discharge
  • B0-B15: Reserved

BXX indicates the bit of the number