Skip to content

Latest commit

 

History

History
 
 

oximeter2

Folders and files

NameName
Last commit message
Last commit date

parent directory

..
 
 
 
 
 
 
 
 
 
 
 
 
 
 

\mainpage Main Page


Oximeter 2 click

Oximeter 2 Click is a compact add-on board suitable for measuring blood oxygen saturation.

click Product page


Click library

  • Author : MikroE Team
  • Date : Dec 2020.
  • Type : I2C type

Software Support

We provide a library for the Oximeter2 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly form compilers IDE(recommended way), or downloaded from our LibStock, or found on mikroE github account.

Library Description

This library contains API for Oximeter2 Click driver.

Standard key functions :

  • Config Object Initialization function.

void oximeter2_cfg_setup ( oximeter2_cfg_t *cfg );

  • Initialization function.

OXIMETER2_RETVAL oximeter2_init ( oximeter2_t *ctx, oximeter2_cfg_t *cfg );

Example key functions :

  • Generic read function.

uint8_t oximeter2_generic_read ( oximeter2_t *ctx, uint8_t reg );

  • Gets state of the int pin

uint8_t oximeter2_get_int_status ( oximeter2_t *ctx );

  • Generic function for reading als and proximity values

uint16_t oximeter3_read_value ( oximeter3_t *ctx, uint8_t type_macro );

Examples Description

This application collects data from the sensor, calculates it and then logs the result.

The demo application is composed of two sections :

Application Init

Initializes driver and performs the device configuration which puts Time Slot A and Time Slot B modes to active state. Before the device configuration, the SW reset will be performed, which puts the registers in their initial state.

void application_init ( void )
{
    log_cfg_t log_cfg;
    oximeter2_cfg_t cfg;
    
    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, "---- Application Init ----" );
    
    //  Click initialization.

    oximeter2_cfg_setup( &cfg );
    OXIMETER2_MAP_MIKROBUS( cfg, MIKROBUS_1 );
    oximeter2_init( &oximeter2, &cfg );
    oximeter2_default_cfg( &oximeter2 );
}
  

Application Task

Application measures value of oxygen level in blood of a human.

void oximeter2_write_res ( uint32_t data_write )
{
    log_printf( &logger, "%u\r\n", data_write );
}

void oximeter2_logs_results( void )
{
    uint8_t final_result;
    
    oximeter2_read_data( &oximeter2, &res_slot[ 0 ] );

    log_printf( &logger, "Average result per photodiode is: \r\n" );
    
    switch ( oximeter2.enabled_channel )
    {
        case OXIMETER2_CH3_CH4_SELECTED:
        {
            log_printf( &logger, "PD3: " );
            oximeter2_write_res( res_slot[ 2 ] );
            log_printf( &logger, "PD4: " );
            oximeter2_write_res( res_slot[ 3 ] );

            final_result = ( res_slot[ 2 ] + res_slot[ 3 ] ) / 1000;
            break;
        }
        case OXIMETER2_ALL_CHANNELS_SELECTED:
        {
            log_printf( &logger, "PD1: " );
            oximeter2_write_res( res_slot[ 0 ] );
            log_printf( &logger, "PD2: " );
            oximeter2_write_res( res_slot[ 1 ] );
            log_printf( &logger, "PD3: " );
            oximeter2_write_res( res_slot[ 2 ] );
            log_printf( &logger, "PD4: " );
            oximeter2_write_res( res_slot[ 3 ]);

            final_result = ( res_slot[ 0 ] + res_slot [ 1 ] + res_slot[ 2 ] + res_slot[ 3 ] ) / 1000;
            break;
        }
        default:
        {
            break;
        }
    }
    
    if (final_result > 100)
    {
        final_result = 100;
    }
    log_printf( &logger, "Average result, in percentage: %u\r\n", ( uint16_t )final_result );
    log_printf( &logger, "-------------------------\r\n" );

    Delay_ms( 300 );
}

void application_task ( void )
{
    oximeter2_logs_results();
}

The full application code, and ready to use projects can be installed directly form compilers IDE(recommneded) or found on LibStock page or mikroE GitHub accaunt.

Other mikroE Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.Oximeter2

Additional notes and informations

Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all Mikroelektronika compilers, or any other terminal application of your choice, can be used to read the message.