\mainpage Main Page
GSM3 click is a complete quad-band GSM cellular network communication solution, featuring the SIM800H-BT, a quad-band 2G GSM/GPRS module. This module is GSM Phase 2/2+ compliant, featuring a full set of options for the cellular networking and communication. It has a network status indication, jamming detection, embedded internet protocols including TCP/IP, UDP, FTP, PPP, HTTP, E-mail, MMS, and more. It also features advanced voice/audio functions, including the FM radio interface. The GPRS multislot class 12 implementation allows 4 uplink and 4 downlink slots, with 5 slots open in total.
- Author : Stefan Filipovic
- Date : May 2023.
- Type : UART type
We provide a library for the GSM3 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.
Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.
This library contains API for GSM3 Click driver.
gsm3_cfg_setup
Config Object Initialization function.
void gsm3_cfg_setup ( gsm3_cfg_t *cfg );
gsm3_init
Initialization function.
err_t gsm3_init ( gsm3_t *ctx, gsm3_cfg_t *cfg );
gsm3_set_sim_apn
This function sets APN for sim card.
void gsm3_set_sim_apn ( gsm3_t *ctx, uint8_t *sim_apn );
gsm3_send_sms_text
This function sends text message to a phone number.
void gsm3_send_sms_text ( gsm3_t *ctx, uint8_t *phone_number, uint8_t *sms_text );
gsm3_send_sms_pdu
This function sends text message to a phone number in PDU mode.
err_t gsm3_send_sms_pdu ( gsm3_t *ctx, uint8_t *service_center_number, uint8_t *phone_number, uint8_t *sms_text );
Application example shows device capability of connecting to the network and sending SMS or TCP/UDP messages using standard "AT" commands.
The demo application is composed of two sections :
Initializes the driver, tests the communication by sending "AT" command, and after that restarts the device.
void application_init ( void )
{
log_cfg_t log_cfg; /**< Logger config object. */
gsm3_cfg_t gsm3_cfg; /**< Click config object. */
/**
* Logger initialization.
* Default baud rate: 115200
* Default log level: LOG_LEVEL_DEBUG
* @note If USB_UART_RX and USB_UART_TX
* are defined as HAL_PIN_NC, you will
* need to define them manually for log to work.
* See @b LOG_MAP_USB_UART macro definition for detailed explanation.
*/
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_info( &logger, " Application Init " );
// Click initialization.
gsm3_cfg_setup( &gsm3_cfg );
GSM3_MAP_MIKROBUS( gsm3_cfg, MIKROBUS_1 );
if ( UART_ERROR == gsm3_init( &gsm3, &gsm3_cfg ) )
{
log_error( &logger, " Application Init Error. " );
log_info( &logger, " Please, run program again... " );
for ( ; ; );
}
gsm3_process( );
gsm3_clear_app_buf( );
// Check communication
gsm3_send_cmd( &gsm3, GSM3_CMD_AT );
error_flag = gsm3_rsp_check( GSM3_RSP_OK );
gsm3_error_check( error_flag );
// Restart device
#define RESTART_DEVICE "1,1"
gsm3_send_cmd_with_par( &gsm3, GSM3_CMD_CFUN, RESTART_DEVICE );
error_flag = gsm3_rsp_check( GSM3_RSP_OK );
gsm3_error_check( error_flag );
log_info( &logger, " Application Task " );
example_state = GSM3_CONFIGURE_FOR_NETWORK;
}
Application task is split in few stages:
- GSM3_CONFIGURE_FOR_NETWORK:
Sets configuration to device to be able to connect to the network.
- GSM3_WAIT_FOR_CONNECTION:
Waits for the network registration indicated via CREG URC event and then checks the connection status.
- GSM3_CONFIGURE_FOR_EXAMPLE:
Sets the device configuration for sending SMS or TCP/UDP messages depending on the selected demo example.
- GSM3_EXAMPLE:
Depending on the selected demo example, it sends an SMS message (in PDU or TXT mode) or TCP/UDP message.
By default, the TCP/UDP example is selected.
void application_task ( void )
{
switch ( example_state )
{
case GSM3_CONFIGURE_FOR_NETWORK:
{
if ( GSM3_OK == gsm3_configure_for_network( ) )
{
example_state = GSM3_WAIT_FOR_CONNECTION;
}
break;
}
case GSM3_WAIT_FOR_CONNECTION:
{
if ( GSM3_OK == gsm3_check_connection( ) )
{
example_state = GSM3_CONFIGURE_FOR_EXAMPLE;
}
break;
}
case GSM3_CONFIGURE_FOR_EXAMPLE:
{
if ( GSM3_OK == gsm3_configure_for_example( ) )
{
example_state = GSM3_EXAMPLE;
}
break;
}
case GSM3_EXAMPLE:
{
gsm3_example( );
break;
}
default:
{
log_error( &logger, " Example state." );
break;
}
}
}
In order for the examples to work, user needs to set the APN and SMSC (SMS PDU mode only) of entered SIM card as well as the phone number (SMS mode only) to which he wants to send an SMS. Enter valid values for the following macros: SIM_APN, SIM_SMSC and PHONE_NUMBER_TO_MESSAGE.
Example:
- SIM_APN "internet"
- SIM_SMSC "+381610401"
- PHONE_NUMBER_TO_MESSAGE "+381659999999"
The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.
Other Mikroe Libraries used in the example:
- MikroSDK.Board
- MikroSDK.Log
- Click.GSM3
Additional notes and informations
Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all MikroElektronika compilers.