Hi @qinwei2004 since you are the author of fvp_boot.c, could you please help here? @xiaoxiang781216 @anchao for awareness |
@lzc1001 I think you should enable
|
Thank you very much! @acassis @anchao |
@anchao Thank you very much! When I add "while (!pl011_irq_tx_ready(sport));" to pl011_send(), the code will pending. So, it mean that the fifo is full. and fifo don't still clean. I start to find the issues location. |
Description
Hi everyone,
In recent, I want to add some _info() in nx_start(), but the information don't print to ternimal on FVP. But I can use "dmesg" instruction to output the log information or set CONFIG_CONSOLE_SYSLOG=y. But the latter is set, the pl011 serial can't be initialized. Then, I find the arm64_earlyserialinit() in fvp_boot.c disable pl011_regs.cr and don't enbale until running DEBUGVERIFY(group_setupidlefiles()) in nx_start(). So, how do I print information before running DEBUGVERIFY(group_setupidlefiles()) and initialize pl011 serial currectly?
Thank you!