diff --git a/BuildClasses/TE_LDN.nml b/BuildClasses/TE_LDN.nml new file mode 100644 index 00000000..f6198473 --- /dev/null +++ b/BuildClasses/TE_LDN.nml @@ -0,0 +1,106 @@ +&specification + BuildingType='LDN_TE_pre1900' + BuildingName='LDN_TE_pre1900' + Height=9.3 + FootprintArea=65.6 + WallExternalArea=147.1 + WWR=0.2 + RatioInternalVolume=0.1 + WallThickness=0.168 + WallEffectiveConductivity=0.596 + WallDensity=1626.237 + WallCp=822.626 + Wallx1=0.291 + FloorThickness=0.235 + GroundFloorEffectiveConductivity=0.752 + GroundFloorDensity=1540.426 + GroundFloorCp=1001.657 + GroundDepth=2.0 + ExternalGroundConductivity=0.0001 + WindowThickness=0.004 + WindowEffectiveConductivity=1.050 + WindowDensity=2500.000 + WindowCp=840.000 + InternalMassDensity=1056.612 + InternalMassCp=1286.081 + IndoorAirDensity=1.2754 + IndoorAirCp=1005 + WallInternalConvectionCoefficient=1.27 + InternalMassConvectionCoefficient=8.29 + FloorInternalConvectionCoefficient=0.96 + WindowInternalConvectionCoefficient=2.34 + WallExternalConvectionCoefficient=8.51 + WindowExternalConvectionCoefficient=5.29 + WallExternalEmissivity=0.900 + WallInternalEmissivity=0.910 + InternalMassEmissivity=0.910 + WindowExternalEmissivity=0.880 + WindowInternalEmissivity=0.880 + WindowTransmissivity=0.800 + WindowAbsorbtivity=0.150 + WindowReflectivity=0.050 + WallTransmissivity=0.000 + WallAbsorbtivity=0.625 + WallReflectivity=0.375 + WallBuildingViewFactor=0.354 + WallGroundViewFactor=0 ! ASHRAE 140 - Case 600 + WallSkyViewFactor=0.646 ! assumed isolated building wall(0.5) and roof (1.0) + Occupants=0 + MetabolicRate=0 + LatentSensibleRatio=0 + ApplianceRating=0 + TotalNumberofAppliances=1 + ApplianceUsageFactor=1 + MaxHeatingPower=1000000.0 ! ASHRAE 140 - Case 600 + HeatingSystemEfficiency=0.9 ! Assumed + MaxCoolingPower=1000000.0 ! ASHRAE 140 - Case 600 + CoolingSystemCOP=3.4 ! Assumed + VentilationRate=0.6 ! ASHRAE 140 - Case 600 (ach) + IndoorAirStartTemperature=20 + IndoorMassStartTemperature=20 + WallIndoorSurfaceTemperature=18 + WallOutdoorSurfaceTemperature=5 + WindowIndoorSurfaceTemperature=18 + WindowOutdoorSurfaceTemperature=5 + GroundFloorIndoorSurfaceTemperature=18 + GroundFloorOutdoorSurfaceTemperature=10.0 + HeatingSetpointTemperature=18 ! ASHRAE 140 - Case 600 + CoolingSetpointTemperature=26 ! ASHRAE 140 - Case 600 + WaterTankTemperature=18 ! Minimised in Volume as not considered in BESTEST - Case 600 + InternalWallWaterTankTemperature=18 ! ASHRAE 140 - Case 600 - influence minimised by volume + ExternalWallWaterTankTemperature=18 ! ASHRAE 140 - Case 600 - influence minimised by volume + WaterTankWallThickness=0.055 ! ASHRAE 140 - Case 600 - influence minimised by volume + MainsWaterTemperature=11 ! ASHRAE 140 - Case 600 - influence minimised by volume + WaterTankWaterVolume=0.0046 ! ASHRAE 140 - Case 600 - influence minimised by volume + WaterTankSurfaceArea=1 ! ASHRAE 140 - Case 600 - influence minimised by volume + HotWaterHeatingSetpointTemperature=10 ! ASHRAE 140 - Case 600 - influence minimised by volume + HotWaterTankWallEmissivity=0.9 ! ASHRAE 140 - Case 600 - influence minimised by volume + DomesticHotWaterTemperatureInUseInBuilding=15 ! ASHRAE 140 - Case 600 - influence minimised by volume + InternalWallDHWVesselTemperature=20 ! ASHRAE 140 - Case 600 - influence minimised by volume + ExternalWallDHWVesselTemperature=20 ! ASHRAE 140 - Case 600 - influence minimised by volume + DHWVesselWallThickness=0.47 ! ASHRAE 140 - Case 600 - influence minimised by volume + DHWWaterVolume=0.0001 ! Minimised for ASHRAE BESTEST + DHWSurfaceArea=0.00001 ! Minimised for ASHRAE BESTEST + DHWVesselEmissivity=0.9 ! Based on Internal ASHARE 140 + HotWaterFlowRate=0.0 ! Minimised for ASHRAE BESTEST + DHWDrainFlowRate=0.0 ! Minimised for ASHRAE BESTEST + DHWSpecificHeatCapacity=4180.1 ! of water + HotWaterTankSpecificHeatCapacity=29.1830 ! ASHRAE 140 - Case 600 - influence minimised by volume + DHWVesselSpecificHeatCapacity=29.1830 ! ASHRAE 140 - Case 600 - influence minimised by volume + DHWDensity=1000 ! of water + HotWaterTankWallDensity=15.8075 ! ASHRAE 140 - Case 600 - influence minimised by volume + DHWVesselDensity=15.8075 ! ASHRAE 140 - Case 600 - influence minimised by volume + HotWaterTankBuildingWallViewFactor=0.2 + HotWaterTankInternalMassViewFactor=0.8 + HotWaterTankWallConductivity=0.00001 ! ASHRAE 140 - Case 600 - set to minimise influence + HotWaterTankInternalWallConvectionCoefficient=0.01 ! ASHRAE 140 - Case 600 - set to minimise influence + HotWaterTankExternalWallConvectionCoefficient=0.01 ! ASHRAE 140 - Case 600 - set to minimise influence + DHWVesselWallConductivity=0.00001 ! ASHRAE 140 - Case 600 - set to minimise influence + DHWVesselInternalWallConvectionCoefficient=0.01 ! ASHRAE 140 - Case 600 - set to minimise influence + DHWVesselExternalWallConvectionCoefficient=0.01 ! ASHRAE 140 - Case 600 - set to minimise influence + DHWVesselWallEmissivity=0.9 ! Based on Internal ASHARE 140 + MaximumHotWaterHeatingPower=10 ! Minimised for ASHRAE BESTEST + HotWaterHeatingEfficiency=0.95 + MinimumVolumeOfDHWinUse=2.0 ! altered to 20% of Vwt upon initiation + +/