NVLeak

Introduction

Experimental environments

Our USENIX Security paper evaluates two server machines equipped with Intel Optane DC Persistent Memory Gen 1, aka Apache Pass. To reproduce our results, we suggest to use Gen 1 Intel Optane DIMM as later generations may have changed their microarchitecture designs.

We set Intel Optane DIMMs in non-interleaved mode and use only one of them for our experiments, so an Intel server machine with at least one Intel Optane DIMM Gen 1 is required to reproduce our results.

We also provide a set of scripts to parse results and generate plots. These scripts do not need to run on the server with Optane DIMM, i.e., they can run on any Linux environment (e.g., your local workstation or laptop).

Terms

In the remaining doc, we use the following terms:

  • NVRAM Server: The Intel server machine equipped with Intel Optane DIMM.
  • Dev Server: The machine that runs scripts to parse results and generate plots. It can be any Linux environment such as your laptop or workstation. It's not preferred to use the NVRAM Server to run these scripts because they run some Docker containers (e.g., MongoDB) which might create noises to the experiment results.

Set up environments

  1. Set up the NVRAM Server environment following the instructions
  2. Set up the Dev Server environment following the instructions

Run experiments on the NVRAM Server

The major claims of our USENIX Security 23 paper are listed below:

In our main paper, Figure 2 to 17 are from the Server A (see Table 1 in the main paper) and Figure 18 is from the Server B and it's from the same experiments as Figure 4-7.

Figure # Type Description
2 Reverse Engineering Recover L1/L2 NVCache sizes and their block sizes
4 Reverse Engineering Recover L1/L2 NVCache set structures
5 Reverse Engineering Recover the wear-leveling policy
6 Reverse Engineering Recover the wear-leveling's trigger condition
7 Reverse Engineering Recover the robustness of wear-leveling data migration
9b & 9c Covert Channel Cross virtual machine covert channel performance and signal
10 Covert Channel Filesystem inode-based covert channel
12 Side Channel Access patterns of SQLite executing different SQL code
13 Side Channel Access patterns of SQLite executing ranged queries
14 Side Channel Access patterns of PMDK key-value store
15 Side Channel Detected function calls from wolfSSL library
16 Mitigation Effectiveness and performance of the PMDK-based mitigation
17 Reverse Engineering Detailed pointer chasing results on Server A
18 Reverse Engineering Reverse engineering results on Server B

NOTE: Reproducing the full results can take up 60 GiB of your disk space to store the result data. Please pre-allocate this disk space, or incrementally reproduce the results and delete the data once the result is reproduced.

To reproduce these results, see the following instructions:

  1. To reproduce reverse engineering results (Figure 2-7 and 17), follow this instruction.
  2. To reproduce covert channel results (Figure 9-10), follow this instruction
  3. To reproduce side channel results (Figure 12-15), follow this instruction
  4. To reproduce the mitigation result (Figure 16), follow this instruction

The estimated resources it takes to reproduce results:

Experiments Human Hour Compute Hour Disk Space
Reverse Engineering 1~2 6 > 18 GiB
Covert Channel 1~2 16 32 GiB
Side Channel 2~4 1 1 GiB
Mitigations 2~3 1 1 GiB