Interfacing with MemCARDuino:

Commands Data Parameters Description Response
GETID 0xA0 - Get identifier "MCDINO"
GETVER 0xA1 - Get firmware version Firmware version byte (Major.Minor).
MCR 0xA2 MSB, LSB Memory Card Read (frame) Data, XOR, Status
MCW 0xA3 MSB, LSB, data, XOR Memory Card Write (frame) Status
Status Data Description
ERROR 0xE0 Invalid command received (error)
GOOD 0x47 Operation successful
BAD_CHECKSUM 0x4E Data corruption occured
BAD_SECTOR 0xFF Outside of max sector range

Communication is done at 115200 bps.

To check if MemCARDuino is connected to the selected COM port send GETID command.
Device should respond with IDENTIFIER.
Optionally you can send a GETVER to get the version of the firmware.

To Read a 128byte frame send a MCR command with MSB byte and LSB byte of the frame you want to read.
MemCARDduino will respond with 128 byte frame data, [MSB xor LSB xor Data] and Memory Card status byte.

To Write a frame send a MCW command with MSB byte and LSB byte, 128 byte data and [MSB xor LSB xor Data].
MemCARDduino will respond with Memory Card status byte.

Checking if Memory Card is connected:

Read a frame from the card and verify the returned status byte.
If it's 0x47 then card is connected. If it's 0xFF card is not connected.