import os
import functions_framework
from datetime import datetime, timedelta
from influxdb_client import InfluxDBClient, Point, WritePrecision # type: ignore
from influxdb_client.client.write_api import SYNCHRONOUS # type: ignore
BUCKET = "frog_fleet"
ORG = "Ribbit Network"
URL = "https://us-west-2-1.aws.cloud2.influxdata.com/"
TOKEN = os.environ['INFLUXDB_TOKEN']
@functions_framework.http
def send_data_2_influx(request):
request_json = request.get_json(silent=True)
request_args = request.args
golioth_msg = request_json
ribbit_msg = golioth_msg['data']['ribbitnetwork.datapoint']
gps_fix = ribbit_msg['gps']['has_fix']
# Check if the gps fix is valid, only send a datapoint if so
if gps_fix:
client = InfluxDBClient(url=URL, token=TOKEN, org=ORG)
write_api = client.write_api(write_options=SYNCHRONOUS)
# Get metadata
device_id = golioth_msg['device_id'] + '_golioth_esp32s3'
timestamp = datetime.utcnow()
# Parse Data
scd30_co2_ppm = ribbit_msg['scd30']['co2']
scd30_humidity = ribbit_msg['scd30']['humidity']
scd30_temp = ribbit_msg['scd30']['temperature']
gps_lat = ribbit_msg['gps']['latitude']
gps_lon = ribbit_msg['gps']['longitude']
gps_alt = ribbit_msg['gps']['altitude']
dps310_pressure = ribbit_msg['dps310']['pressure']
dps310_temp = ribbit_msg['dps310']['temperature']
allocated_mem = ribbit_msg['memory']['allocated']
free_mem = ribbit_msg['memory']['free']
battery_voltage = 0.0
if 'battery' in ribbit_msg:
battery_voltage = ribbit_msg['battery']['voltage']
point = (
Point("ghg_reading")
.tag("host", device_id)
.time(timestamp, WritePrecision.NS)
.field("co2", float(scd30_co2_ppm))
.field("temperature", scd30_temp)
.field("humidity", scd30_humidity)
.field("lat", gps_lat)
.field("lon", gps_lon)
.field("alt", gps_alt)
.field("baro_pressure", dps310_pressure)
.field("baro_temperature", dps310_temp)
.field("mem_allocated", allocated_mem)
.field("mem_free", free_mem)
.field("bat_volts", battery_voltage)
)
write_api.write(BUCKET, ORG, point)
else:
print('no gps_fix: not submitting to influxDB')
#Must send HTTP Return Code