If "Fan:VariableVolume" in the "Supply Air Fan Object Type" field, it needs to be changed to "Fan:SystemModel". A "Fan:SystemModel" object need to be created based on the former "Fan:VariableVolume" object. A fan power curve will be created as well that holds the "Fan Power Coefficient i" in Fan:VariableVolume.
Cooling and Heating: inserted "Heat Recovery Inlet Node Name", "Heat Recovery Outlet Node Name", and "Heat Recovery Reference Flow Rate" fields; new optional "Heat Recovery Capacity Modifier Function of Temperature Curve Name", "Heat Recovery Electric Input to Output Ratio Modifier Function of Temperature Curve Name" fields
Cooling: new optional "Maximum Heat Recovery Outlet Temperature", "Thermosiphon Capacity Fraction Curve Name", and "Thermosiphon Minimum Temperature Difference" fields
Heating: new optional "Minimum Heat Recovery Outlet Temperature" field
Chiller:Electric:EIR and Chiller:Electric:ReformulatedEIR: new optional "Condenser Flow Control", "Condenser Loop Flow Rate Fraction Function of Loop Part Load Ratio Curve Name", "Temperature Difference Across Condenser Schedule Name", "Condenser Minimum Flow Fraction", "Thermosiphon Capacity Fraction Curve Name", and "Thermosiphon Minimum Temperature Difference" fields
Chiller:Electric and Chiller:ConstantCOP: new optional "Thermosiphon Capacity Fraction Curve Name" and "Thermosiphon Minimum Temperature Difference" fields <--- these aren't wrapped
New additions
Site:Location: new optional "Keep Site Location Information" field
Sizing:Zone: new optional "Type of Space Sum to Use" field
AirTerminal:SingleDuct:SeriesPIU:Reheat and AirTerminal:SingleDuct:ParallelPIU:Reheat: new optional "Fan Control Type", "Minimum Fan Turn Down Ratio", "Heating Control Type", "Design Heating Discharge Air Temperature", and "High Limit Heating Discharge Air Temperature" fields
InternalMass: field "Zone or ZoneList Name" is no longer required
I left things alone and just put a comment in FT: "As of E+ v24.2, Zone Name is ignored when Space Name is specified"
RoomAir:Node:AirflowNetwork:HVACEquipment: WaterHeater:HeatPump keys for "ZoneHVAC or Air Terminal Equipment Object Type" field have changed -- not wrapped
Output:IlluminanceMap: field "Zone Name" has changed to "Zone or Space Name"
ZoneRefrigerationDoorMixing: fields "Zone Name 1" and "Zone Name 2" changed to "Zone or Space Name 1" and "Zone or Space Name 2" -- not wrapped
ZoneCoolTower:Shower: field "Zone Name" changed to "Zone or Space Name" -- not wrapped
ZoneThermalChimney: fields "Zone 1 Name" changed to "Zone or Space 1 Name" and "Relative Ratios of Air Flow Rates Passing through Zone 1" changed to "Relative Ratios of Air Flow Rates Passing through Inlet 1" -- not wrapped
Other
The text was updated successfully, but these errors were encountered:
@wsjsxn Not sure I follow here. We're in the process of updating to v24.2.0, so your question seem too early perhaps? Anyways, in the end, you'll just be able to add it to a tertiary loop for heat recovery.
Enhancement Request
Once v24.2-IOFreeze is released, we should update to it.
Detailed Description
https://github.com/NREL/EnergyPlus/blob/develop/src/Transition/InputRulesFiles/Rules24-1-0-to-24-2-0.md
https://github.com/NREL/EnergyPlus/blob/develop/src/Transition/OutputRulesFiles/OutputChanges24-1-0-to-24-2-0.md
Major changes
ZoneHVAC:TerminalUnit:VariableRefrigerantFlow
V24.2.0-IOFreeze: VRF's supply fan from VariableVolume to SystemModel #5255HeatPump:PlantLoop:EIR:XXX
V24.2.0-IOFreeze: HeatPumpPlantLoopEIR's new "Heat Recovery XXX" fields #5244Cooling
andHeating
: inserted "Heat Recovery Inlet Node Name", "Heat Recovery Outlet Node Name", and "Heat Recovery Reference Flow Rate" fields; new optional "Heat Recovery Capacity Modifier Function of Temperature Curve Name", "Heat Recovery Electric Input to Output Ratio Modifier Function of Temperature Curve Name" fieldsCooling
: new optional "Maximum Heat Recovery Outlet Temperature", "Thermosiphon Capacity Fraction Curve Name", and "Thermosiphon Minimum Temperature Difference" fieldsHeating
: new optional "Minimum Heat Recovery Outlet Temperature" fieldChiller
V24.2.0-IOFreeze: ChillerElectric's new fields #5254Chiller:Electric:EIR
andChiller:Electric:ReformulatedEIR
: new optional "Condenser Flow Control", "Condenser Loop Flow Rate Fraction Function of Loop Part Load Ratio Curve Name", "Temperature Difference Across Condenser Schedule Name", "Condenser Minimum Flow Fraction", "Thermosiphon Capacity Fraction Curve Name", and "Thermosiphon Minimum Temperature Difference" fieldsChiller:Electric
andChiller:ConstantCOP
: new optional "Thermosiphon Capacity Fraction Curve Name" and "Thermosiphon Minimum Temperature Difference" fields <--- these aren't wrappedNew additions
Site:Location
: new optional "Keep Site Location Information" fieldSizing:Zone
: new optional "Type of Space Sum to Use" fieldAirTerminal:SingleDuct:SeriesPIU:Reheat
andAirTerminal:SingleDuct:ParallelPIU:Reheat
: new optional "Fan Control Type", "Minimum Fan Turn Down Ratio", "Heating Control Type", "Design Heating Discharge Air Temperature", and "High Limit Heating Discharge Air Temperature" fieldsSpaceHVAC:ZoneReturnMixer
: new objectOutputControl:Files
: insert new "Output Space Sizing" fieldMinor stuff
InternalMass
: field "Zone or ZoneList Name" is no longer required-- not wrappedRoomAir:Node:AirflowNetwork:HVACEquipment
: WaterHeater:HeatPump keys for "ZoneHVAC or Air Terminal Equipment Object Type" field have changedOutput:IlluminanceMap
: field "Zone Name" has changed to "Zone or Space Name"-- not wrappedZoneRefrigerationDoorMixing
: fields "Zone Name 1" and "Zone Name 2" changed to "Zone or Space Name 1" and "Zone or Space Name 2"-- not wrappedZoneCoolTower:Shower
: field "Zone Name" changed to "Zone or Space Name"-- not wrappedZoneThermalChimney
: fields "Zone 1 Name" changed to "Zone or Space 1 Name" and "Relative Ratios of Air Flow Rates Passing through Zone 1" changed to "Relative Ratios of Air Flow Rates Passing through Inlet 1"Other