Command name | INS | Description |
---|---|---|
GET_VERSION |
0x03 | Get application version as MAJOR , MINOR , PATCH |
GET_APP_NAME |
0x04 | Get ASCII encoded application name |
GET_PUBLIC_KEY |
0x05 | Get public key given BIP32 path |
SIGN_TX |
0x06 | Sign transaction given BIP32 path and raw transaction |
GET_ADDRESS_PROOF |
0x08 | Sign an address proof in TON Connect 2 compliant format given BIP32 path and proof parameters |
SIGN_DATA |
0x09 | Sign custom data in TON Connect 2 compliant format |
GET_APP_SETTINGS |
0x0A | Get app settings |
CLA | INS | P1 | P2 | Lc | CData |
---|---|---|---|---|---|
0xE0 | 0x03 | 0x00 | 0x00 | 0x00 | - |
Response length (bytes) | SW | RData |
---|---|---|
3 | 0x9000 | MAJOR (1) || MINOR (1) || PATCH (1) |
CLA | INS | P1 | P2 | Lc | CData |
---|---|---|---|---|---|
0xE0 | 0x04 | 0x00 | 0x00 | 0x00 | - |
Response length (bytes) | SW | RData |
---|---|---|
var | 0x9000 | APPNAME (var) |
Use P2 to control what kind of address to present to user:
- set bit 0x01 to make address testnet only
- set bit 0x02 to use masterchain instead of basechain for the address
- set bit 0x04 to include is_v3r2 flag and subwallet_id
The bip32 path must be at least 3 elements long and must start with the prefix m/44'/607'/
.
CLA | INS | P1 | P2 | Lc | CData |
---|---|---|---|---|---|
0xE0 | 0x05 | 0x00 (no display) 0x01 (display) |
0x00-0x07 | 1 + 4n + (0 or 5) | len(bip32_path) (1) ||bip32_path{1} (4) ||... ||bip32_path{n} (4) ||(if P2 & 0x04 ) is_v3r2 (1) (0x00 or 0x01 ) ||(if P2 & 0x04 ) subwallet_id (4) |
Response length (bytes) | SW | RData |
---|---|---|
32 | 0x9000 | public_key (32) |
Sent as series of packages. First one contains bip32 path, which must be at least 3 elements long and must start with the prefix m/44'/607'/
:
CLA | INS | P1 | P2 | Lc | CData |
---|---|---|---|---|---|
0xE0 | 0x06 | 0x00 | 0x03 (first & more) | 1 + 4n | len(bip32_path) (1) ||bip32_path{1} (4) ||... ||bip32_path{n} (4) |
Then an arbitrary number of chunks with transaction data (see TRANSACTION.md), up to a total of 510 bytes (currently, max valid transaction data length is 299 bytes).
CLA | INS | P1 | P2 | Lc | CData |
---|---|---|---|---|---|
0xE0 | 0x06 | 0x00 | 0x02 (more) 0x00 (last) |
len(chunk) |
chunk |
Response length (bytes) | SW | RData |
---|---|---|
98 | 0x9000 | len(signature) (1) || signature (64) || len(hash) (1) || hash (32) || |
Use P2 to control what kind of address to present to user:
- set bit 0x01 to make address testnet only
- set bit 0x02 to use masterchain instead of basechain for the address
- set bit 0x04 to include is_v3r2 flag and subwallet_id
The bip32 path must be at least 3 elements long and must start with the prefix m/44'/607'/
.
Payload's length is implicitly calculated from buffer length.
Proofs are generated according to this spec.
CLA | INS | P1 | P2 | Lc | CData |
---|---|---|---|---|---|
0xE0 | 0x08 | 0x01 | 0x00-0x03 | 1 + 4n + 1 + d + 8 + p | len(bip32_path) (1) ||bip32_path{1} (4) ||... ||bip32_path{n} (4) ||(if P2 & 0x04 ) is_v3r2 (1) (0x00 or 0x01 ) ||(if P2 & 0x04 ) subwallet_id (4) ||len(app_domain) == d (1) ||app_domain (d) ||timestamp (8) ||payload (p) |
Response length (bytes) | SW | RData |
---|---|---|
98 | 0x9000 | len(signature) (1) || signature (64) || len(hash) (1) || hash (32) || |
Signatures are generated according to this spec.
Sent as series of packages. First one contains bip32 path, which must be at least 3 elements long and must start with the prefix m/44'/607'/
:
CLA | INS | P1 | P2 | Lc | CData |
---|---|---|---|---|---|
0xE0 | 0x09 | 0x00 | 0x03 (first & more) | 1 + 4n | len(bip32_path) (1) ||bip32_path{1} (4) ||... ||bip32_path{n} (4) |
Then an arbitrary number of chunks with serialized custom data (see CUSTOM_DATA.md), up to a total of 510 bytes.
CLA | INS | P1 | P2 | Lc | CData |
---|---|---|---|---|---|
0xE0 | 0x09 | 0x00 | 0x02 (more) 0x00 (last) |
len(chunk) |
chunk |
Response length (bytes) | SW | RData |
---|---|---|
98 | 0x9000 | len(signature) (1) || signature (64) || len(hash) (1) || hash (32) || |
CLA | INS | P1 | P2 | Lc | CData |
---|---|---|---|---|---|
0xE0 | 0x0A | 0x00 | 0x00 | 0x00 | - |
True/false settings are sent as bitfields, currently all settings fit in one byte, future versions may add additional flags to that byte or add new bytes.
In the current version, flags
has:
- bit
0x01
set if blind signing is enabled - bit
0x02
set if expert mode is enabled
Response length (bytes) | SW | RData |
---|---|---|
1 | 0x9000 | flags (1) |
SW | SW name | Description |
---|---|---|
0x6985 | SW_DENY |
Rejected by user |
0x6A86 | SW_WRONG_P1P2 |
Either P1 or P2 is incorrect |
0x6A87 | SW_WRONG_DATA_LENGTH |
Lc or minimum APDU length is incorrect |
0x6D00 | SW_INS_NOT_SUPPORTED |
No command exists with INS |
0x6E00 | SW_CLA_NOT_SUPPORTED |
Bad CLA used for this application |
0xB000 | SW_WRONG_RESPONSE_LENGTH |
Wrong response length (buffer size problem) |
0xB002 | SW_DISPLAY_ADDRESS_FAIL |
Address conversion to string failed |
0xB003 | SW_DISPLAY_AMOUNT_FAIL |
Amount conversion to string failed |
0xB004 | SW_WRONG_TX_LENGTH |
Wrong raw transaction length |
0xB010 | SW_TX_PARSING_FAIL |
Failed to parse raw transaction |
0xB005 | SW_WRONG_SIGN_DATA_LENGTH |
Wrong raw custom data length |
0xB011 | SW_SIGN_DATA_PARSING_FAIL |
Failed to parse raw custom data |
0xB007 | SW_BAD_STATE |
Security issue with bad state |
0xB008 | SW_SIGNATURE_FAIL |
Signature of raw transaction failed |
0xB00B | SW_REQUEST_TOO_LONG |
The request is too long |
0xB0BD | SW_BAD_BIP32_PATH |
The bip32 derivation path is invalid |
0xBD00 | SW_BLIND_SIGNING_DISABLED |
A blind transaction was requested, but blind signing is disabled |
0x9000 | OK |