Important: Since Proteus does not support two MAF sensors at the moment, I will make a workaround:
- both MAF sensors are installed and connected to Proteus
- IAT sensor of first MAF ist connected to Proteus
- an additional MAP sensor is installed to detect the load
- Bosch 0 280 218 019
- HFM5 - 4.7 analog sensor
- with NTC
- Range: -30 - 640kg/h
- Size: 70 x 96mm
- Plug Housing: 1928403836
- Pins
- 1987280103 0.5mm² - 1mm²; Gasket: 1987280106
- 1987280105 1.5mm² - 2.5mm²; Gasket: 1987280107
Output voltage Ua = f(Qm)
Qm, kg/h | Ua, V |
---|---|
8 | 1.2390 |
10 | 1.3644 |
15 | 1.5241 |
30 | 1.8748 |
60 | 2.3710 |
120 | 2.9998 |
250 | 3.7494 |
370 | 4.1695 |
480 | 4.4578 |
Temperature sensor
Temperature, °C | Resistance, Ohm |
---|---|
-40 | 39260 |
-30 | 22960 |
-20 | 13850 |
-10 | 8609 |
0 | 5499 |
10 | 3604 |
20 | 2420 |
30 | 1662 |
40 | 1166 |
50 | 835 |
60 | 609 |
70 | 452 |
80 | 340 |
90 | 261 |
100 | 202 |
110 | 159 |
120 | 127 |
130 | 102 |
- Bosch 0 280 218 081
- HFM5 - 4.7 analog sensor
- with NTC
- Range: 10 - 480kg/h
- Size: 70 x 96mm
- Plug Housing: 1928403836
- Pins
- 1987280103 0.5mm² - 1mm²; Gasket: 1987280106
- 1987280105 1.5mm² - 2.5mm²; Gasket: 1987280107
Output voltage Ua = f(Qm)
Qm, kg/h | Ua, V |
---|---|
8 | 1.2968 |
10 | 1.3700 |
15 | 1.5201 |
30 | 1.8577 |
60 | 2.3517 |
120 | 2.9658 |
250 | 3.7090 |
370 | 4.1266 |
480 | 4.4093 |
Temperature sensor
Temperature, °C | Resistance, Ohm |
---|---|
-40 | 39260 |
-30 | 22960 |
-20 | 13850 |
-10 | 8609 |
0 | 5499 |
10 | 3604 |
20 | 2420 |
30 | 1662 |
40 | 1166 |
50 | 835 |
60 | 609 |
70 | 452 |
80 | 340 |
90 | 261 |
100 | 202 |
110 | 159 |
120 | 127 |
130 | 102 |