According to this diagram, E2 heater is PC8: https://github.com/FYSETC/FYSETC-S6/blob/main/hardware/V2.0/S6%20V2.0%20Postion.pdf
But in this diagram, PC8 is given as the bed heater output: https://github.com/Klipper3d/klipper/blob/master/config/generic-fysetc-s6-v2.cfg
I have found this to be PB15.
The text was updated successfully, but these errors were encountered:
Equally, E1 heater is PB4, not PC7.
Sorry, something went wrong.
No branches or pull requests
According to this diagram, E2 heater is PC8:
https://github.com/FYSETC/FYSETC-S6/blob/main/hardware/V2.0/S6%20V2.0%20Postion.pdf
But in this diagram, PC8 is given as the bed heater output: https://github.com/Klipper3d/klipper/blob/master/config/generic-fysetc-s6-v2.cfg
I have found this to be PB15.