Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Defrost state #125

Open
frassefraze opened this issue Oct 16, 2024 · 3 comments
Open

Defrost state #125

frassefraze opened this issue Oct 16, 2024 · 3 comments

Comments

@frassefraze
Copy link

First off, I absolutely love the project—thank you for all your hard work! My system has been running smoothly for over a year now, adjusting the temperature based on electricity prices to avoid excessive heating during expensive periods.

I wonder if it’s possible to add a state or similar feature for the defrosting. It would be nice to track how often defrosting occurs and detect any anomalies, particularly if it starts running too frequently. Is this something that the units can report, feels like something that should be able to pickup ?

@willie013
Copy link

I think the panasonic interface doesn't provide this information, and the estimated energy consumption has quite a delay on it to detect this. Using an external power monitor plug might be the best solution here, you would just need a control algorithm to reliably determine if the unit is defrosting (it might also be cycling since temp is reached). This is something I want to try as well in the near future

@frassefraze
Copy link
Author

You’re probably right. But it just seems like something that should be possible to detect. My units closes up, and the floor unit flashes a blue LED for "DEICE" (I’m not sure about the wall-mounted unit, but it likely behaves similarly), there are several things happening at the same time.
I attempted to debug the interface to find the relevant rows, but the data being sent and received is a bit complex for me. Plus, I need to catch the logs when a defrost is starting or at least ongoing.
But please let me know if you come up with a good workaround or solution.

@redbullterror
Copy link

Hello i have check de rx with defrost and without maybe you can use it.

Normal 70.20.44.30.80.A0.30.00.00.40.00.00.48.2E.00.00.00.00.16.01.FF.18.01.FF.80.80.FF.80.14.00.01.80.69.65.E6 (35) Defrost 70.20.44.30.80.A0.30.00.00.40.00.00.4C.2E.02.00.00.00.16.01.FF.18.01.FF.80.80.FF.80.2A.00.03.80.69.65.C8 (35)
bit 15 change from 00 to 02

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment