# -*- coding: utf-8 -*-
"""
Created on Sun Dec 25 20:34:28 2016
@author: shubaraghavan
"""
#returns energy in BTU
#https://www.e-education.psu.edu/egee102/node/2070
#http://www.sensiblehouse.org/nrg_heatloss.htm
from HDD_CDD_UValues import *
from UValues import *
def AnnualEngDemand(fuel, HDD, size1, size2,Rval0, Rval1, Rval2, heaterEF):
#==============================================================================
# HDD is the sum of all [houly average degrees below the thermostat
# set temp] in ayear
# Rval - ft2·°F·hr/Btu
# Size1 #surface area of walls
# Size2 #surface area of roof, floor
#==============================================================================
# print "HDD", HDD,Rval0, Rval1, size1,size2, windowPerc,heaterEF
Rval3 = 0.048 # floor
HeatLoss3 = 0
windowArea= windowPerc * size1
size1 = (1-windowPerc)* size1 #wall area without window
HeatLoss0 = (HDD *24.0 *windowArea)/Rval0 #window
HeatLoss1 = (HDD *24.0 * size1) /(Rval1) # walls #BTU
HeatLoss2 = (HDD *24.0 * size2) /(Rval2) #Roof
# HeatLoss3 = (HDD *24.0 * size2) /(Rval3) #Flooe
# HeatLoss3 = (HDD *24.0 * size2) /Rval2 #floor
# print "HeatLoss", HeatLoss1, HeatLoss2
AnnualHeatRequired = HeatLoss3 + HeatLoss1 + HeatLoss2 + HeatLoss0 #+HeatLoss3
AnnualHeatDemand = AnnualHeatRequired/heaterEF
# print "Annual Heat Demand", Rval0, Rval1, Rval2, HDD, heaterEF, AnnualHeatRequired, AnnualHeatDemand
# print "AnnualHeatDemand in kBTU", fuel.name,AnnualHeatDemand/1000, "\n"
#print "Ann HD", AnnualHeatDemand
return AnnualHeatDemand
#==============================================================================
# if fuel.name == 'NG':
# return (AnnualHeatDemand/Therm_BTU)
# elif fuel.name =='Elec':
# return AnnualHeatDemand/kWh_BTU
#
#=============================================================================
def AnnualCoolingDemand(fuel, CDD, size1,size2,Rval0, Rval1, Rval2, coolerEF):
# print "HDD", CDD,Rval0, Rval1, size1,size2,windowPerc, coolerEF
Rval3 = 0.048
HeatLoss3 = 0
windowArea= windowPerc * size1
size1 = (1-windowPerc)*size1
HeatLoss0 = (CDD *24.0 *windowArea)/Rval0 #window
HeatLoss1 = (CDD * 24.0 * size1) /(Rval1) # walls #BTU
HeatLoss2 = (CDD * 24.0 * size2) /(Rval2) #Roof
# HeatLoss3 = (CDD * 24.0 * size2) /(Rval3) #Roof
# HeatLoss3 = (CDD * 24.0 * size2) /Rval2 #floor
# print "HeatLoss", HeatLoss1, HeatLoss2
AnnualCoolRequired = HeatLoss3 + HeatLoss1 + HeatLoss2 + HeatLoss0 # +HeatLoss3
AnnualCoolDemand = AnnualCoolRequired/coolerEF
# print "Annual Cool Demand", AnnualHeatDemand
# print "AnnualCoolDemand in kBTU", fuel.name,AnnualHeatDemand/1000, "\n"
return AnnualCoolDemand