Skip to content

Latest commit

 

History

History
133 lines (97 loc) · 6.79 KB

324131092621.md

File metadata and controls

133 lines (97 loc) · 6.79 KB
title description addedAt pageClass
Philips 324131092621 control via MQTT
Integrate your Philips 324131092621 via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway.
2019-07-22 20:08:17 UTC
device-page

Philips 324131092621

Model 324131092621
Vendor Philips
Description Hue dimmer switch
Exposes battery, action_duration, action, linkquality
Picture Philips 324131092621

Notes

Battery Type

Uses a CR2450 battery.

Pairing

Factory reset the Hue dimmer switch by pressing and holding the setup button on the back for 10 seconds.

Restart the Hue dimmer switch by holding all 4 buttons of the Hue dimmer switch. You can let go when the light on the front flashes red/green briefly.

Using the dimmer to reset other Zigbee devices

Many devices can be factory reset / re-paired with a help of Hue dimmer switch:

  1. Make sure your device is powered on.
  2. Take the dimmer and hold the ON and OFF buttons close to your device for approximately 10 seconds.
  3. After about 10 seconds both your Zigbee device and the Hue dimmer should flash.
  4. Hold it down for a further one second.
  5. Your device should now be discoverable by your network.

To use the Hue dimmer switch to factory reset a Hue light bulb see HOWTO: Factory reset a Hue bulb.

This method also works for Philips Hue Lightstrips, IKEA Trådfri, Sonoff ZBMINI, and Tuya light bulbs.

Binding

By default, the device is bound to the coordinator, but it can also be used to directly control other lights and switches in the network (see guide on binding).

As the device is sleeping by default, you will need to wake it up after sending the bind/unbind command by pressing any button.

When endpoint 1 is bound to a light or a group of lights, the behavior is as follows:

Button Click Action Comment
On Single
Long
Turn on Using the commandOn command.
Brightness up Single Step up the brightness In steps of 30 points (around 12%), using the commandStep command with {"stepmode":0,"stepsize":30,"transtime":9} payload.
Brightness up Long Smoothly increase the brightness In steps of 56 points (around 22%), using the commandStep command with {"stepmode":0,"stepsize":56,"transtime":9} payload.
Sends the commandStop command, on button release.
Brightness down Single Step down the brightness In steps of 30 points (around 12%), using the commandStep command with {"stepmode":1,"stepsize":30,"transtime":9} payload.
Brightness down Long Smoothly decrease the brightness In steps of 56 points (around 22%), using the commandStep command with {"stepmode":1,"stepsize":56,"transtime":9} payload.
Sends the commandStop command, on button release.
Off Single
Long
Turn off Using the commandOffWithEffect command with {"effectid":0,"effectvariant":0} payload.

Troubleshooting

Resetting the device

  • Method 1: Press all four buttons for 4 seconds. When the light turns green, release the buttons. The device will flash green and red alternatively after which it will reconnect to the network.
  • Method 2: Use a needle or paperclip to press the reset button on the back for 10 seconds. The behavior is similar to method 1

Device refuses actions

If actions (e.g. applying zigbee2mqtt/bridge/request/device/remove to a dimmer) result in timeouts, perform a reset (see above) and apply the action right after the device announced itself in the network.

Device announces itself but the buttons don't work

The dimmer appears to be working normally and the logs in Zigbee2MQTT look good. However, nothing happens when a button is pressed (no light, no log message in Zigbee2MQTT). In this case:

  • Reset the device
  • Use zigbee2mqtt/bridge/request/device/remove to remove the device from the network (this should result in a "left the network" log message)
  • Allow joining of new devices in Zigbee2MQTT
  • Reset the device again
  • Wait for it to pair again. The device should now be operational.

OTA updates

This device supports OTA updates, for more information see OTA updates.

Options

How to use device type specific configuration

  • legacy: Set to false to disable the legacy integration (highly recommended), will change structure of the published payload (default true). The value must be true or false

  • simulated_brightness: Simulate a brightness value. If this device provides a brightness_move_up or brightness_move_down action it is possible to specify the update interval and delta. The action_brightness_delta indicates the delta for each interval. Only works when legacy is false. Example:

simulated_brightness:
  delta: 20 # delta per interval, default = 20
  interval: 200 # interval in milliseconds, default = 200

Exposes

Battery (numeric)

Remaining battery in %, can take up to 24 hours before reported. Value can be found in the published state on the battery property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 100. The unit of this value is %.

Action duration (numeric)

Triggered action duration in seconds. Value can be found in the published state on the action_duration property. It's not possible to read (/get) or write (/set) this value. The unit of this value is s.

Action (enum)

Triggered action (e.g. a button click). Value can be found in the published state on the action property. It's not possible to read (/get) or write (/set) this value. The possible values are: on_press, on_press_release, on_hold, on_hold_release, up_press, up_press_release, up_hold, up_hold_release, down_press, down_press_release, down_hold, down_hold_release, off_press, off_press_release, off_hold, off_hold_release.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.